1. Introduction
Bilateral telerobotic systems have fundamentally transformed the way humans interact with distant objects. These kinesthetically coupled systems facilitate an operator in receiving haptic feedback from a local device as the remote manipulator engages with its environment. This additional feedback channel enhances the operator’s ability to perform delicate tasks with higher precision and situational awareness, significantly reducing the time needed to complete tasks (e.g., see refs. [Reference Gani, Pickering, Ellis, Sabri and Pucher1, Reference Louca, Eder, Vrublevskis and Tzemanaki2]). Consequently, telerobotic systems have become indispensable in critical sectors such as nuclear facilities (e.g., material handling, waste disposal, or fusion power plant maintenance), space and underwater explorations, military operations, and telesurgery, underlining their importance through decades of extensive research [Reference Darvish, Penco, Ramos, Cisneros, Pratt, Yoshida, Ivaldi and Pucci3, Reference Zhang, Zhang, Cheng, Cheng, Zhang and Lu4].
Two critical performance metrics in these systems are effort transparency—the ability of the system to accurately transmit forces and torques between the local and remote manipulators—and back drivability, which refers to the system’s capability to allow the local manipulator to be controlled through movements applied at the remote manipulator. Both are essential for ensuring that the operator experiences realistic and responsive interactions during teleoperation.
Central to the design of bilateral teleoperation systems is achieving absolute stability, especially given the highly uncertain and variable dynamics of human arm and environmental interactions [Reference Tugal, Carrasco, Falcon and Barreiro5]. Balancing stability with performance presents a major design challenge, making it a focal point of discussion in the field [Reference Banks, Salehizadeh, Munawar, Taylor and Tumerdem6, Reference Duan, Li and Li7]. Historically, performance evaluations have primarily assessed position tracking and force reflection. However, these assessments have mostly been limited to single-degree-of-freedom (DoF) systems, which are inadequate for evaluating multi-DoF systems [Reference Beerens, Heck, Saccon and Nijmeijer8].
Recent research has introduced advanced metrics and techniques for evaluating telerobotic systems. For example, a cloud-based approach for nondestructive material characterization [Reference Heidari, Navimipour and Otsuki9] could enhance real-time inspection in telerobotic environments. Similarly, methods for optimizing energy consumption in wireless sensor networks [Reference Heidari, Navimipour and Unal10] could improve data transmission and control in systems relying on wireless communication. These efforts have contributed to the ongoing development of robust, efficient telerobotic systems.
However, despite well-established evaluation methodologies for industrial manipulators and collaborative robots (e.g., ISO 9283:1998, ISO/TS 150:2016), a standardized approach for assessing multi-DoF bilateral telerobotic systems remains absent [Reference Samur11]. This lack of standardization is particularly evident in evaluating critical performance criteria such as stiffness [Reference Beerens, Heck, Saccon and Nijmeijer8] and backdrivability across different mechanical design philosophies [Reference Buongiorno, Chiaradia, Marcheschi, Solazzi and Frisoli12]. The absence of a standardized evaluation framework highlights the need for developing methodologies that can experimentally assess these critical performance aspects.
Previous studies on bilateral telerobotic systems primarily focused on bandwidth and frequency response, which are difficult to quantify or measure [Reference Brooks13, Reference Uebel, Ali and Minis14]. Early performance measures, such as peak force, peak acceleration, and impedance characteristics, were introduced by Hayward et al. [Reference Hayward and Astley15]. Later studies, such as those by Cavusoglu [Reference Çavuşoğlu, Feygin and Tendick16] and Taati [Reference Taati, Tahmasebi and Hashtrudi-Zaad17], identified specific performance measures for haptic interfaces, while backdrivability was experimentally evaluated in ref. [Reference Li and Kawashima18] against communication delays. A comprehensive review of haptic system evaluations, covering both qualitative and quantitative aspects, was detailed in ref. [Reference Samur11].
Effort transparency remains a key performance metric for haptic systems, with various control methodologies proposed to enhance it [Reference Deng, Tang, Yang, Zheng, Liu and Liu19]. In an ideal bilateral telerobotic system, the force/torque applied at the local end would be seamlessly transmitted to the remote end [Reference Nahri, Du and Van Wyk20]. Achieving perfect transparency is difficult due to stability constraints, as well as hysteresis introduced by system dynamics.
Also, the ratio between an applied force and the resulting displacement is important in both the local and remote manipulators which is known as stiffness (also referred to as lost motion and rigidity) [Reference Görgülü, Dede and Carbone21–Reference Salcudean and Vlaar24]. Typically, high degrees-of-freedom bilateral telerobotic setups are position-based systems; force reflection on the local side is achieved by comparing the pose of the local and remote manipulators [Reference Skilton, Hamilton, Howell, Lamb and Rodriguez25]. Therefore, stiffness is a critical criterion, as a low value might result in a spongy feeling when the remote manipulator interacts with a stiff object [Reference Chu, Zhang, Zhang, Xu, Ryu and Wang26, Reference Louca, Eder, Vrublevskis and Tzemanaki2 Reference Duan, Li and Li7].
Backdrivability refers to a system’s capability to operate in reverse, allowing manipulation of the local arm by driving the remote arm [Reference Gosselin, Ferlay and Janot28]. In position-based bilateral telerobotic systems, where the remote joint angle is controlled by the local joint angles, backdrivability is also essential for generating positional discrepancies that contribute to the sensation of effort at the local side, ultimately influencing overall transparency [Reference Li and Kawashima18, Reference Li, Liu, Wang, Kawashima and Magid29]. Additionally, highly backdrivable systems offer substantial operational flexibility, reducing the risk of damage during contact with harsh environments and providing a safety margin [Reference Gosselin, Ferlay and Janot28]. Therefore, assessing system performance includes considering its backdrivability as a valuable indicator.
This study aims to contribute to the broader efforts of standardizing evaluation methodologies for bilateral telerobotic systems, which will enhance consistency in development, manufacturing, and procurement processes. Here, we experimentally evaluate quantitative performance measures—such as effort transparency, stiffness, and back drivability—of two nuclear-rated bilateral telerobotic systems known as Telbot and Dexter. Alongside presenting performance results, the paper comprehensively outlines test procedures, measurement methods, and conditions. This approach aims to establish accepted sets of performance measures and benchmarks, facilitating comparison between different designs while potentially guiding future developments.
2. Methods
2.1. Notations
Bold lower-case letters, $\boldsymbol{x}$ , represent the column vectors, nonbold upper case-letters, $X$ , denote matrices, nonbold lower-case letters, $x$ , represent single variables, and $^\top$ denotes the transpose. The transformation from a vector to a skew-symmetric matrix is denoted by $\left [\,\right ]_\times$ operator. The identify matrix is denoted as $\text{I}$ .
2.2. Experimental setup
The experiment utilized two advanced robotic systems, the Telbot and Dexter, both dual-arm bilateral teleoperation systems with distinct mechanical design philosophies. These systems consist of local and remote manipulators designed for precise teleoperation tasks. The details of the systems’ configurations are shown in Figures 1 and 2.
The Telbot and Dexter systems are bilateral teleoperation setups, each driven by gears and tendons, respectively. Both systems feature local and remote manipulators. Excluding the gripper, Telbot’s local manipulator offers seven degrees of freedom and is capable of carrying up to 20 kg at the end-effector. Dexter’s local manipulator provides six degrees of freedom with a payload capacity of 10 kg. Remote control for both systems is facilitated through their local manipulators: in Telbot, the remote arm has a kinematically similar structure, whereas Dexter’s remote arm is identical to its local counterpart.
Telbot’s remote arm uses a mechanism where the motion is transmitted from base-located motors to the end-effector via concentric tubes and bevel gears, allowing for unrestricted rotation across all axes. This design provides a positioning accuracy of 0.1 mm for repeated movements [Reference Wälischmiller and Lee30]. Conversely, Dexter’s lightweight manipulators transmit motion through tendons, from base-located motors to the handle or end-effector. Both local and remote arms of Dexter possess six degrees of freedom and are operated manually by human users.
To measure transmitted effort, ATI Gamma Force/Torque (FT) sensors (calibrated with SI 330-30) were installed close to the handle point on the local side and the tool center point (TCP) on the remote side. These sensors captured the transmitted effort between the operator and the manipulators (and between manipulator and the environment) during the experiment.
These telerobotic interfaces are designed for operator use. However, human-in-the-loop experiments can be highly variable and difficult to replicate. To introduce consistent positional disturbances, we used high-resolution multiaxis motorized stages that could be controlled remotely. These stages were mounted at the operational points of both the local and remote manipulators. For added safety, the telerobotic systems were activated and deactivated remotely. Telbot’s enabling switch, located on the handle, was controlled by a solenoid system. This remote activation feature complemented existing safety barriers and external emergency switches.
To induce perturbations in both local and remote manipulators along the $x$ , $y$ , $z$ , roll ( $r_x$ ), pitch ( $r_y$ ), and yaw ( $r_z$ ) directions, multiple motorized stages were assembled, as shown in Figure 3. When perturbing the local manipulator, an FT sensor was mounted at the tip of the translational and rotational stages and connected to the tip of the local manipulator using a custom attachment tools.
Typically, a displacement exists between the sensor frame’s origin and the main contact point’s origin (e.g., the handle point at the local or the tool center point at the remote sides) due to the attachment tools. This displacement affects the transformation of forces and torques (FT) from the sensor frame to the contact point. In that case, the force/torque vector at the handle, $\boldsymbol{f}_h$ , is related to the sensor frame measurement, $\boldsymbol{f}_{tcp}$ , as
where $\boldsymbol{f}_s = \begin{bmatrix} f^x_s & f^y_s & f^z_s & \tau ^x_s & \tau ^y_s & \tau ^z_s \end{bmatrix}^{\top }$ is the FT exerted by the handle (end-effector) on its environment, derived from the FT sensor reading by removing the efforts generated by the weight of the tool (and then taking the negative as the force sensor measurement is the actual force applied by the end-effector on the environment where in bilateral system we are interested how much environmental force transmitted to the human/operator hand). The origin of the sensor frame ( $s$ ) with respect to the contact point position in the sensor frame is denoted by the position vector $\boldsymbol{p}^s_{c}$ . This equation allows us to transform the sensor’s FT readings to the actual point of interest, compensating for any displacement caused by tool attachments. All reported efforts refer to those measured at the handle and tool-centre points in the depicted base frame.
2.3. Experimental procedures
2.3.1. Testing conditions
In both systems, the operator could adjust the level of haptic feedback through the human–machine interface (HMI). For the Telbot system, the feedback was set to 100% (full force/torque feedback), while for Dexter, the tests were conducted using a 1.5 scale ratio for the force feedback, which is the default setting recommended by the manufacturer. This scale ratio reduce the perceived force by 1.5 times, providing the operator with sufficient sensitivity to remote manipulations, facilitating finer control.
The performance measures in these systems are inherently dependent on the operating point. To ensure consistency across trials, the remote manipulator in both systems was positioned near the center of the operational workspace during the experiments. For example, in Dexter, this meant that each joint was positioned approximately midway between its upper and lower limits, which represents the normal operating posture of the system.
Prior to each test, all systems were powered on for 30–45 minutes to allow the equipment to stabilize at its nominal operating temperature. This step is critical, particularly for mitigating sensor output drift—especially in force/torque (FT) sensors, which are susceptible to drift over time due to fluctuations in temperature and gage excitation voltage. By allowing the system to reach thermal equilibrium, we reduced the risk of inaccurate measurements. To further counteract sensor drift, the FT sensors were biased before each testing cycle in accordance with the manufacturer’s guidelines. Although biasing does not eliminate drift entirely, it effectively reduces the cumulative effect, ensuring that sensor outputs start from zero at the beginning of each cycle.
To minimize the impact of thermal drift during extended testing periods, we used 3D-printed plastic tools as attachments, which offered better thermal stability compared to metal components.
The temperature of the ambient environment during the tests was $(20 \pm 2.5)^{\circ }$ C, in line with the industrial manipulator performance measure standard [31]. Since the measurement took place in the premises that were not air-conditioned, it was not possible to secure the temperature $(20 \pm 2.0)^{\circ }$ C. The tests were conducted in the allowed temperature range specified by the manufacturer of the Telbot and Dexter: ( ${10}^{\circ }$ C to ${40}^{\circ }$ C), FT sensor (( $0^{\circ }$ C to ${70}^{\circ }$ C)).
In addition to reporting the standard deviations from multiple measurements, we conducted a comprehensive review of potential sources of error that could have impacted the experimental results. All force/torque sensors were calibrated by the manufacturers using appropriate calibration ranges to ensure accuracy. The mechanical rigidity of the system was thoroughly examined, and any potential deflections in the tools and attachment links were minimized through adjustments made prior to the experiments.
2.3.2. Initialization and data collection protocol
A slowly increasing and decreasing ramp input is applied to the motorized stages, allowing for the generation of an output versus input force graph. This curve, also known as the transparency curve of a device, illustrates the linearity of force transmission. From this graph, various output force limits can be extracted, such as the maximum continuous force (due to saturation), dead zone (attributed to stiction and Coulomb friction), and hysteresis (resulting from backlash, loose components, and friction). The slope of the linear portion of the calibration curve, known as sensitivity, reflects the change in output for a unit change in input, with higher sensitivity being desirable for any bilateral teleoperation system. The limit of the dead zone indicates the minimum force that a haptic device can generate [Reference Samur11], also referred to as the static friction breakaway (SFB) force. This term denotes the minimum amount of force or torque required at the local side to initiate the transmission of effort to the remote side.
Tests were conducted in six directions within the Cartesian frame. In each test, the end effector of the local arm (the handle) was displaced with a velocity of 0.01 mms $^{-1}$ (0.01 $^\circ$ s $^{-1}$ 0) at linear (orientation) frames, reaching a maximum of 4 mm (2 $^\circ$ ) in 10 cycles, see Table I. In each direction, two sets of experiments were conducted–one in the positive direction and one in the negative direction.
In order to test effort transparency of the bilateral teleoperation systems, FT sensors were mounted to the local arm handle point and remote arm TCP, also motorized stages were mounted to the local arm as seen in Figure 3. The diagram illustrating the overall test setup is presented in Figure 4.
The stiffness tests were conducted with FT sensors and motorized stages mounted on the local manipulators. The remote manipulator grasped a stiff plate, and in Dexter, remote manipulators’ brakes were engaged. and in the Telbot, the grippers were mechanically locked to prevent any undesirable displacement at the TCP. Positional displacement is applied to the local arms by gradually increasing the ramp input to the motorized stages. The diagram illustrating the overall test setup is presented in Figure 5.
Stiffness is a fundamental concept in both mechanics and control systems, describing how much an object resists deformation in response to applied forces or torques. Using Hooke’s law, stiffness is defined as a linear relationship between the applied force/torque and the corresponding displacement:
where $K \in \mathbb{R}^{6\times 6}$ is symmetric and positive definite stiffness matrix, representing the system’s resistance to deflection in both translational and rotational directions. The displacement vector is denoted as $\Delta \boldsymbol{p} = \begin{bmatrix} \Delta p^x & \Delta p^y & \Delta p^z & \Delta \theta ^x & \Delta \theta ^y & \Delta \theta ^z \end{bmatrix}^{\top }$ , where $\Delta p$ and $\Delta \theta$ represent linear and angular displacements, respectively. And $\boldsymbol{f} = \begin{bmatrix} f^x & f^y & f^z & \tau ^x & \tau ^y & \tau ^z \end{bmatrix}^{\top }$ is the effort vector [Reference Carbone32, Reference Deng, Tang, Yang, Zheng, Liu and Liu19].
This equation is crucial for analysing the system’s stiffness behavior, especially in the context of bilateral teleoperation, where stiffness needs to be carefully controlled to ensure both stability and transparency.
During the backdrivability test, the local manipulator is allowed to move freely, while positional displacement is applied at the remote end. Ideally, the local position should track the remote’s position within a stability boundary. Thus, motorized stages were only mounted on the remote manipulator end-effector, and the actuators were operated while the local arm was in free space. The diagram illustrating the overall test setup is presented in Figure 6.
3. Main results
We evaluated the transparency, stiffness, and backdrivability of telerobotic systems. Statistical analyses were conducted to determine if there were significant differences between left and right hands or among the manipulators. Normality tests confirmed that all data groups followed a normal distribution at a significance level of 0.05.
To assess effort transparency, we used Welch’s t-test (implemented in Matlab using ttest2()). A significance threshold of 0.05 was maintained for all statistical tests in this study.
3.1. Effort transparency results
In dynamic tasks, one critical parameter is the effort transmission point, often referred to as the SFB point. This point indicates where static friction is overcome, allowing movement to occur. It can be identified by the peak in the derivative of the remote force/torque vector (i.e., yank) [Reference Lin, McGowan, Blum and Ting33] as:
where $f_{tcp}^i$ is the force/torque component in the $i$ -th operational space direction. The derivative $\frac{d\mid f_{tcp}^i\mid }{dt}$ captures the rate of change of the force/torque, with the maximum point indicating the SFB.
To minimize the influence of sensor noise and ensure accurate identification of the breakaway point, a Savitzky-Golay filter is applied to smooth the force/torque data. This filtering technique preserves the significant features of the signal while reducing noise, enabling precise identification of the first effort transmission point. Figure 7 illustrates local and remote forces and position of the local manipulator (i.e., motorized stages) while conducting force transparency test with Telbot left-hand-side arm in $z$ -direction.
The estimated SFB FT for the Telbot manipulators is given in Table II. In the left-hand side (LHS), the system demonstrated force transmission starting values ranging from 1.8163 N (in the $x$ -direction) to 4.5536 N (in the $z$ -direction). Additionally, the LHS exhibited moment transmission values, with $r_x$ , $r_y$ , and $r_z$ values at 0.6772 N m, 1.1361 N m, and 0.7755 N m, respectively. On the right-hand side (RHS), the force sensitivity ranged from 1.1461 N (in the $y$ -direction) to 2.0707 N (in the $z$ -direction), while the moment transmission starting values was notable in $r_x$ (0.5745 N m), $r_y$ (0.0027 N m, that is a significantly lower value due to estimating points only close to/similar to the starting points), and $r_z$ (0.4234 N m). These findings provide a comprehensive understanding of the telerobotic system’s operator’s sensitivity to external forces and moments across different axes.
Although the Telbot LHS and RHS arms are identical, their friction compensation parameters are tuned differently in the low-level controller.Footnote 1 This leads to varied outcomes, with the LHS arm typically requiring higher efforts to initiate transmission to the remote side across multiple axes. The analyses indicate a statistically significant difference ( $p = 0.000364$ ) in translational SFB FT between Telbot’s LHS and RHS.
The estimated SFB FT for the Dexter manipulators is provided in Table II as well. The lightweight, low-inertia mechanical design of both the local and remote manipulators, combined with the tendon driving mechanism, influences the estimated results. As a result, relatively low effort is required in both the LHS and RHS Dexter arms to initiate the transmission of effort to the remote side.
The Telbot system exhibits higher SFB forces in all translational directions compared to the Dexter system (p = 0.0001). Specifically, the $z$ -direction in Telbot shows significant force resistance, with the LHS recording a breakaway force of 4.5536 N and the RHS at 2.0707 N, whereas Dexter’s corresponding values are much lower at 0.4812 N and 1.6475 N, respectively. These findings suggest that Telbot may be more suitable for tasks requiring higher translational stiffness and resistance to displacement.
The effort sensitivity of both bilateral telerobotic systems for translation and rotation axes is depicted in Figure 8. The hysteresis curve in Dexter is relatively lower compared to that in Telbot.
3.2. Stiffness results
During the tests, FT measurements were taken on the local side, while displacements were recorded on both the local and remote sides. Stiffness values for both the Telbot and Dexter are provided in Tables III and IV, respectively. Higher stiffness values indicate increased rigidity in the corresponding axes. Typically, in the base frame, forward/backward ( $x$ ) and upward/downward ( $z$ ) stiffness values are relatively higher compared to side stiffness. The utilization of a gear-driven system on the remote side affects stiffness performance, and the Telbot system demonstrates notably higher stiffness values across all directions, particularly in the $z$ -axis, with stiffness values reaching 2897.69 N m $^{-1} $ on the LHS and 3317.39 N m $^{-1} $ on the RHS. Dexter’s stiffness values in the same axis are considerably lower, indicating reduced resistance to vertical deflection. This implies that the Telbot system is better equipped to handle forces and torques with minimal deformation, especially in tasks involving vertical loads, see Figure 9.
Similar observation can be made on the rotational stiffness, Telbot has higher stiffness values in most directions, particularly in $r_x$ and $r_y$ . For instance, the $r_y$ stiffness in Telbot is 180.4621 N m rad $^{-1}$ on the LHS, whereas Dexter exhibits lower stiffness at 41.1875 N m rad $^{-1}$ . These differences may influence the system’s ability to handle rotational movements without excessive deflection. Stiffness testing could not be conducted for one rotation axis ( $r_z$ ) with Telbot due to limitations in the torque of the motorized stages (the use of ’N/A’ appropriately signifies instances).
3.3. Backdrivability results
To conduct backdrivability tests, motorized stages were mounted on the remote manipulators near the TCP (see Figure 6), and the actuators were operated while the local arm was in free space. The mechanical design of the Telbot remote arms, which incorporates gears from the base to the TCP for radiation protection, suggests that the system is not backdrivable. This characteristic is evident in Figure 10, where an application of approximately 200 N from the remote side is necessary to move both remote and local arms around 15 mm. The conducted test specifically focused on the $z$ -axis to prevent any potential damage to the robotic system. In contrast, Dexter is backdrivable as seen in Figure 10, where the remote manipulator is easily manipulated via the motorized stages with 5 N of effort, and the local manipulator closely follows the position of the remote manipulator.
4. Discussion
In addition to the performance criteria mentioned earlier, we also stress the systems to their operational limits to observe their behavior when operating beyond design boundaries. This is crucial for overall safety, as it ensures that the systems do not enter limit cycles–persistent oscillations with fixed amplitude and frequency. Such oscillations or vibrations may occur when the local manipulator is pushed close to its operational limits, such as when external forces are applied near maximum levels. One can state that both systems can be pushed to their limits without compromising safety, as no limit cycles were observed.
Effort transparency emerges as a pivotal performance criterion, although not explicitly specified by the manufacturer. These systems are primarily designed to transmit remote side efforts to the local side, enabling operators to execute precise manipulations without hardware and tool damage. The Dexter and Telbot performed well in force transparency, where approximately 1 N and 4 N from the local side are sufficient to transmit effort to the remote side, respectively. In free space, Dexter is highly transparent, requiring operators to apply only about 5 N. However, with Telbot, operators need to apply approximately 20 N, equivalent to handling around 2 kg during operations. This unintended impedance can contribute to fatigue during prolonged operations, and operators may find it challenging to distinguish efforts at the remote side less than 25 N (approximately 2.5 kg).
In any teleoperation system, whether uni- or bilateral, the primary performance requirement is the position tracking of the remote manipulator, where it is expected that the remote replicates the position displacement of the local manipulator. Although the accuracy is not reported here due to the lack of high-precision position measurement sensors, the representation of position displacement on the remote side is crucial. During the tests, it was observed that the position tracking of the remote Telbot manipulator contains discrete jumps (approximately 2 mm at the TCP) while tracking the position of the local arm, as shown in Figure 11 (a) (refer to Figure 11 (b) for the Dexter as a comparison). This nonlinear positional displacement is noticeable to the operators and can be attributed to the mechanical design of the telerobotic system, which includes various gears.
4.1. Potential limitations
While every effort was made to mitigate some limitations (e.g., sensor and actuator limitations, mechanical rigidities and communication constraints), some inherent constraints in both the mechanical setup and the electrical systems may still influence the results. For example, slight mechanical deflections, sensor drift, and real-world communication latency might not be fully eliminated, despite our careful design and setup. These factors should be kept in mind when interpreting the experimental results, and further refinements in both hardware and testing conditions may be necessary for future work to reduce these limitations further.
5. Conclusion
In this article, we conducted a thorough evaluation of the performance of bilateral telerobotic systems, using the Telbot and Dexter dual-hand systems as case studies. We specifically examined the performances of the LHS and RHS systems, two distinct entities sharing the HMI for operational purposes. Alongside presenting measured performances, we detailed the test methodology and experiment procedures to standardize the evaluation of bilateral telerobotic systems. These operational capabilities provided crucial insights into their limitations, particularly important in scenarios such as nuclear operations where remote robustness is paramount.
Position tracking serves as a quantitative measure of performance; however, we acknowledged that in human-operated systems, operators may prioritize the manner in which motions are transmitted. They may prefer a linear, smooth transition over a non-linear hysteresis pattern. For a more comprehensive evaluation, future research will expand on performance metrics such as position accuracy and repeatability. Additionally, qualitative psychophysical tests via an operator study will provide a better understanding of human–robot interaction preferences, contributing to the design of more efficient and intuitive telerobotic systems.
In addition to evaluating the Telbot and Dexter systems, this study sets the stage for future work on standardizing the evaluation of bilateral telerobotic systems. By outlining a replicable methodology, we aim to contribute to the growing efforts to unify testing and operational metrics in this emerging field, ultimately benefiting the entire value chain—from design engineers to end users.
Author contributions
HT, FA, MS, SS, WL, HMR, and KZ conceived and designed the study. HT, FA, MS, and SS performed the experimental testing and data collection. HT, FA, and WL conducted the data analysis, and HT wrote the article. IC and RS participated in proofreading.
Financial support
This research was fully funded within the LongOps program by UKRI under the Project Reference 107463, NDA, and TEPCO. The views and opinions expressed herein do not necessarily reflect those of the organizations.
Competing interests
The authors declare no conflicts of interest exist.
Ethical approval
Not applicable.