Hostname: page-component-586b7cd67f-dsjbd Total loading time: 0 Render date: 2024-11-27T13:35:11.818Z Has data issue: false hasContentIssue false

The New 14C Analysis Laboratory in Jena, Germany

Published online by Cambridge University Press:  18 July 2016

A Steinhof*
Affiliation:
Max-Planck-Institut für Biogeochemie, Postfach 100164, 07701 Jena, Germany.
G Adamiec
Affiliation:
Departamento de Física Teórica, Atómica, Molecular y Nuclear, Facultad de Ciencias, Universidad de Valladolid, 47011 Valladolid, Spain.
G Gleixner
Affiliation:
Max-Planck-Institut für Biogeochemie, Postfach 100164, 07701 Jena, Germany.
G J van Klinken
Affiliation:
Polykatikia Iatrou Roulia, Paralio Astros, Greece.
T Wagner
Affiliation:
Max-Planck-Institut für Biogeochemie, Postfach 100164, 07701 Jena, Germany.
*
Corresponding author. Email: [email protected].
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The new accelerator mass spectrometry (AMS) Radiocarbon Analysis Laboratory in Jena is described. The laboratory developed a combustion system for solid samples and a CO2 extraction system for air samples. Thus far, sample preparation, including graphitization, was performed in the laboratory, and the samples were measured subsequently by other AMS facilities. Currently, the laboratory owns a 3MV AMS system from HVEE (Netherlands) that has passed the acceptance tests and will be used for routine 14C determinations in the near future. The AMS system is equipped with 2 ion sources, one suitable for graphite targets and the second for both graphite and CO2 targets.

Type
Articles
Copyright
Copyright © 2004 by the Arizona Board of Regents on behalf of the University of Arizona 

References

Aerts-Bijma, AT, van der Plicht, J, Meijer, HAJ. 2001. Automatic AMS sample combustion and CO2 collection. Radiocarbon 43(1):293–8.CrossRefGoogle Scholar
Bronk Ramsey, C, Hedges, REM. 1997. Hybrid ion sources: radiocarbon measurements from microgram to milligram. Nuclear Instruments and Methods in Physics Research B 123:539–45.Google Scholar
Bronk Ramsey, C, Ditchfield, P, Humm, M, Leach, P. 2004. Using a gas ion source for radiocarbon AMS and GCAMS. Radiocarbon , these proceedings.Google Scholar
Gottdang, A, Klein, M, Mous, DJW. 2001. Accelerator mass spectrometry at High Voltage Engineering Europe (HVEE). Radiocarbon 43(1):149–56.CrossRefGoogle Scholar
Nadeau, M-J, Grootes, PM, Voelker, A, Bruhn, F, Duhr, A, Oriwall, A. 2001. Carbonate 14C background: Does it have multiple personalities? Radiocarbon 43(1):169–76.Google Scholar
Rozanski, K, Stichler, W, Gonfiantine, R, Scott, EM, Beukens, RP, Kromer, B, van der Plicht, J. 1992. The IAEA 14C intercomparison exercise 1990. Radiocarbon 34(3):506–19.CrossRefGoogle Scholar