Hostname: page-component-cd9895bd7-fscjk Total loading time: 0 Render date: 2024-12-25T16:28:48.141Z Has data issue: false hasContentIssue false

Tracing Hi Beyond the Local Universe

Published online by Cambridge University Press:  08 November 2017

Martin Meyer*
Affiliation:
International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia
Aaron Robotham
Affiliation:
International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia
Danail Obreschkow
Affiliation:
International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia
Tobias Westmeier
Affiliation:
International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia
Alan R. Duffy
Affiliation:
Centre for Astrophysics and Supercomputing, Swinburne University of Technology, PO Box 218, Hawthorn, VIC 3122, Australia
Lister Staveley-Smith
Affiliation:
International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia
Rights & Permissions [Opens in a new window]

Abstract

The SKA and its pathfinders will enable studies of H i emission at higher redshifts than ever before. In moving beyond the local Universe, this will require the use of cosmologically appropriate formulae that have traditionally been simplified to their low-redshift approximations. In this paper, we summarise some of the most important relations for tracing H i emission in the SKA era, and present an online calculator to assist in the planning and analysis of observations (http://hifi.icrar.org).

Type
Research Article
Copyright
Copyright © Astronomical Society of Australia 2017 

1 INTRODUCTION

Neutral atomic hydrogen (H i) is one of the most important tracers for studying the assembly of mass, angular momentum, and structure in the Universe (Staveley-Smith & Oosterloo Reference Staveley-Smith and Oosterloo2015; Blyth et al. Reference Blyth2015; Kim et al. Reference Kim, Wyithe, Power, Park, Lagos and Baugh2015, Reference Kim, Wyithe, Baugh, Lagos, Power and Park2017; Obreschkow et al. Reference Obreschkow, Glazebrook, Kilborn and Lutz2016). However, the difficulty of observing emission from this material has meant that most studies have been restricted to the local Universe, with only a small fraction of detections occurring beyond redshift z ~0.1 (Jaffé et al. Reference Jaffé, Poggianti, Verheijen, Deshev and van Gorkom2013; Giovanelli & Haynes Reference Giovanelli and Haynes2016). As powerful new radio telescopes come online (ASKAP, MeerKAT, WRST-Apertif, FAST, SKA), such observations will become commonplace (Duffy et al. Reference Duffy2012; Holwerda, Blyth, & Baker Reference Holwerda, Blyth, Baker, Tuffs and Popescu2012; Staveley-Smith & Oosterloo Reference Staveley-Smith and Oosterloo2015), necessitating the use of formulae that allow for an evolving Universe. A basic summary of the cosmologically appropriate formulae for a variety of standard H i quantities is given in the following sections, with the aim of providing a reference document for upcoming pathfinder studies. In the final section, we introduce an accompanying online calculator based on the provided formulae. Useful references for work underpinning the material here include Hogg (Reference Hogg1999), Abdalla & Rawlings (Reference Abdalla and Rawlings2005), Obreschkow et al. (Reference Obreschkow, Heywood, Klöckner and Rawlings2009), Ned Wright’s online tutorialFootnote 1 , and CosmoCalcFootnote 2 .

2 REDSHIFT

For observational H i studies, the redshift of a source is simply defined as

(1) $$\begin{eqnarray} z_{\rm obs} = \frac{\nu _{\textnormal {{H{\sc \,i}}}}}{\nu _{\rm obs}} - 1 = \frac{\lambda _{\rm obs}}{\lambda _{\textnormal {{H{\sc \,i}}}}} - 1, \end{eqnarray}$$

where $\nu _{\textnormal {{H{\sc \,i}}}}$ and $\lambda _{\textnormal {{H{\sc \,i}}}}$ are the emitted frequency and wavelength of the H i line, and νobs and λobs are the corresponding frequency and wavelength at which it is observed. This redshift is the combined result of a number of potentially contributing effects, including the cosmological redshift due to the expansion of the Universe, local motions in either the source or observer rest frames, and gravitational redshifts caused by (evolving) potential wells along the line of sight. Considering just the cosmological redshift (z cos) and the peculiar motions of the source (z source pec) and observer (z observer pec) (Davis & Scrimgeour Reference Davis and Scrimgeour2014):

(2) $$\begin{eqnarray} 1+z_{\rm obs} = (1+z_{\rm cos})(1+z_{\rm pec}^{\rm source})(1+z_{\rm pec}^{\rm observer}) . \end{eqnarray}$$

Different standards of rest or flow models are often used to minimise peculiar velocity effects, particularly in the nearby Universe. At higher redshifts (e.g. z ≳ 0.03, Baldry et al. Reference Baldry2012), the cosmic microwave background offers a reference frame that can be used to remove local peculiar velocity effects, reducing Equation (2) to

(3) $$\begin{eqnarray} 1+z_{\rm obs} = (1+z_{\rm cos})(1+z_{\rm pec}^{\rm source}) . \end{eqnarray}$$

As a general note, the effects of peculiar velocities are multiplicative in 1 + z rather than additive in velocity, as shown in the equations above, and any corrections for peculiar velocity effects need to be similarly applied, such as when making doppler corrections to data taken at different epochs.

In this paper, unless otherwise specified, we make the overall simplifying assumption that the observed redshift is equal to the cosmological redshift (z obs = z cos = z, i.e. z observer pec = z source pec = 0), but be aware that, particularly in the local Universe, there can be a non-negligible difference between these redshifts and you may need to adjust for this assumption.

3 PARAMETERISATIONS OF COSMIC EXPANSION

The relationship between proper (physical) distance and the recessional velocity of galaxies due to the expansion of the Universe at a given epoch is parameterised through the Hubble parameter H(z), with Hubble’s Constant H 0 = H(0) its value at the present time. If we divide the energy density of the Universe, normalised by the critical energy density, into its fractional components of matter (ΩM), radiation (ΩR), vacuum energy (ΩΛ), and also include a term for spatial curvature (ΩK = 1 − Ω = 1 − ΩM − ΩR − ΩΛ), then we can express H(z) (Weinberg Reference Weinberg2008):

(4) $$\begin{equation} H(z) = H_{\rm 0} E(z), \end{equation}$$

where

(5) $$\begin{equation} E(z) = \sqrt{\Omega _{\rm R}(1+z)^{4} + \Omega _{\rm M}(1+z)^{3} + \Omega _{\rm K}(1+z)^{2} + \Omega _{\rm \Lambda } }. \end{equation}$$

Note that the Ω i values here correspond to those at z = 0, and that the above expression does not include any redshift-dependent factors alongside ΩΛ. If desired, a model can also be included for a varying vacuum energy density, as discussed in Section 20.

The dependence of a given quantity on the Hubble constant is often explicitly stated alongside the physical units of a measurement through the use of the dimensionless Hubble constant (‘little h’):

(6) $$\begin{eqnarray} h \equiv \frac{H_{\rm 0}}{100\, \mathrm{km\, s^{-1} Mpc^{-1}}} . \end{eqnarray}$$

The various uses of this quantity and its pitfalls are well described in Croton (Reference Croton2013). In this paper, and to further aid the comparison of values contained in the historical literature, we give all Hubble constant dependencies in terms of h C, allowing for the practice sometimes used of specifying the precise value of H 0 used in the little h nomenclature:

(7) $$\begin{eqnarray} h_{\rm C} \equiv \frac{H_{\rm 0}}{\it C\,\, \mathrm{km\, s^{-1} Mpc^{-1}}} . \end{eqnarray}$$

An explanation of how to convert values from one value of the Hubble constant to another with a specified h C dependence is given in Appendix A.

4 COSMOLOGICAL DISTANCES

There are a number of cosmological distances relevant to the calculation and understanding of H i quantities, most notably including the line-of-sight comoving distance to a galaxy (D C), the transverse comoving distance (D M), the luminosity distance to a galaxy (D L), and the angular diameter distance (D A). Following Hogg (Reference Hogg1999), the comoving distance D C is given by

(8) $$\begin{eqnarray} D_{\rm C}(z) = \frac{c}{H_{\rm 0}}\int _{0}^{z} E^{-1}(z^{\prime }){d}z^{\prime }, \end{eqnarray}$$

where E(z) is as expressed in Equation (5). As before, this can also be modified to include a model for a varying vacuum energy density if desired. From D C, we can then express the transverse comoving distance D M:

(9) $$\begin{equation} D_{\rm M}(z)= \left\lbrace \begin{array}{@{}l@{\quad }l@{}}\frac{c}{H_{\rm 0}\sqrt{\Omega _{\rm K}}} {\rm sinh} \left( \frac{H_{\rm 0}\sqrt{\Omega _{\rm K}}}{c} D_{\rm C}\right) & \text{if } \Omega _{\rm K} > 0, \\ D_{\rm C} & \text{if } \Omega _{\rm K} = 0,\\ \frac{c}{H_{\rm 0}\sqrt{|\Omega _{\rm K}|}} {\rm sin} \left( \frac{H_{\rm 0}\sqrt{|\Omega _{\rm K}|}}{c} D_{\rm C}\right) & \text{if } \Omega _{\rm K} < 0, \end{array}\right. \end{equation}$$

and finally the luminosity distance D L and angular diameter distance D A:

(10) $$\begin{eqnarray} D_{\rm L}(z) &=& (1+z)D_{\rm M}(z), \end{eqnarray}$$
(11) $$\begin{eqnarray} D_{\rm A}(z) &=& D_{\rm M}(z)/(1+z). \end{eqnarray}$$

As these distances are all inversely proportional to the chosen value of the Hubble constant, this dependence can be included explicitly via little h in the units, e.g. h −1 C Mpc.

5 LINE-OF-SIGHT VELOCITY

The various different definitions of velocity offer a significant potential source of confusion, particularly given the historical use of velocity in H i spectral line studies to describe both rest frame motions (i.e. the motions of objects through space), V pec, as well as a proxy for redshift caused by the expansion of space, V cos.

Beginning with the full relativistic expressions for these two velocities, for V pec, we have the special relativity expression (Einstein Reference Einstein1905; Davis, Lineweaver, & Webb Reference Davis, Lineweaver and Webb2003):

(12) $$\begin{equation} V_{\rm pec}(z_{\rm pec}) = V_{\rm SR}(z_{\rm pec}) , \end{equation}$$
(13) $$\begin{equation} \hphantom{V_{\rm pec}(z_{\rm pec})V_{\rm pec}}= c\, \frac{ \nu _{\rm rest}^2 - \nu _{\rm obs}^2 }{ \nu _{\rm rest}^2 + \nu _{\rm obs}^2 } , \end{equation}$$
(14) $$\begin{equation} \hphantom{V_{\rm pec}VV_{\rm pec}(z_{\rm pec})V_{\rm pec}}= c\, \frac{(1+z_{\rm pec})^2 - 1}{ (1+z_{\rm pec})^2 + 1 } , \end{equation}$$

where these equations assume that motion is purely along the line of sight relative to the observer (see Einstein for the relevant equations where the source has a transverse velocity component), and that the observer is in the same inertial reference frame as the source.

In comparison, for V cos, we have the general relativistic expression (Davis et al. Reference Davis, Lineweaver and Webb2003):

(15) $$\begin{eqnarray} V_{\rm cos}(z_{\rm cos}, z_{\rm ref}) = V_{\rm GR}(z_{\rm cos}, z_{\rm ref}) , \end{eqnarray}$$
(16) $$\begin{eqnarray} \hphantom{V_{\rm cos}(z_{\rm cos}, z_{\rm ref}) z_{\rm ref}) z_{\rm ref})}&=& c \frac{H(z_{\rm ref})}{1+z_{\rm ref}} \int ^{z_{\rm cos}}_{0} \frac{{d}z^{\prime }_{\rm cos}}{H(z^{\prime }_{\rm cos})} , \end{eqnarray}$$

where z ref is the redshift at which the velocity is to be evaluated. In practice, as we are observing the object at z cos at the current epoch, z ref = 0. In this situation, the above equation simplifies to (and as used in CosmoCalc)

(17) $$\begin{eqnarray} V_{\rm cos}(z_{\rm cos}) &=& c \int ^{z_{\rm cos}}_{0} E^{-1}(z^{\prime }) \ {d}z^{\prime } . \end{eqnarray}$$

Comparing the above expression with Equation (8), it can be seen that V cos then is the velocity that restores a basic Hubble Law relation V cos(z) = D C(z)/H 0 for all redshifts.

For small redshifts (z < 0.1), both the special relativistic and general relativistic formulae can be approximated by the ‘optical’ velocity convention (to distinguish this from the now deprecated ‘radio’ velocity alternative):

(18) $$\begin{equation} V_{\rm opt}(z)=cz . \end{equation}$$

As a general rule to avoid confusion, the use of velocities is best restricted to describe source rest frame motions (e.g. galaxy rotation, peculiar velocities), and not as a proxy for observed frame quantities (e.g. cosmological redshift, distance, or observed frame frequency width). To separate these two potential uses of velocity in the rest of the paper, we refer to V rest (≡ cz pec, as in general for H i, V pecc and so this is a good approximation of V SR) and for the non-recommended observed frame velocity, we refer to V obs (≡ cz obs, which while only an accurate approximation of V GR at low redshift, has the advantage that it is readily invertible to obtain the source redshift if desired, and is the form that has traditionally been used in the literature). For reference, a comparison plot showing the differences between V SR(z), V GR(z), and V opt(z) can be found in Davis & Lineweaver (Reference Davis, Lineweaver, Durrer, Garcia-Bellido and Shaposhnikov2001).

6 EMISSION PROFILE WIDTH

Along with redshift, another key parameter that can be measured from H i profiles is their frequency width, which provides a line-of-sight measure of velocity differences in the source material, predominantly caused by galaxy rotation. In a similar vein to the discussion of the previous section, to avoid confusion, it is recommended that widths in the source rest frame be specified in terms of velocity, ΔV rest, while those in the observed frame be given in frequency, Δνobs. The relation between the two can be derived from Equation (3). Using the non-relativistic approximation for rest frame velocity width, z pec = ±V pec/c = ±ΔV rest/(2c), this gives

(19) $$\begin{eqnarray} \Delta \nu _{\rm obs} &=& \frac{\nu _{\rm \textnormal {{H{\sc \,i}}}}}{c(1+z_{\rm cos})\left(1 - \left(\frac{\Delta V_{\rm rest}}{2c} \right)^{2}\right)} \Delta V_{\rm rest} . \end{eqnarray}$$

Given the non-relativistic assumption ΔV restc, and again assuming that any systematic peculiar velocity can be ignored (z obs = z cos = z), Equation (19) simplifies to the basic relations used in this paper to convert between ΔV rest and Δνobs:

(20) $$\begin{eqnarray} \Delta V_{\rm rest} &\simeq & \frac{c(1+z)}{\nu _{\rm \textnormal {{H{\sc \,i}}}}}\Delta \nu _{\rm obs} = \frac{c}{\nu _{\rm obs}}\Delta \nu _{\rm obs} . \end{eqnarray}$$

While discouraged, if you need to convert between observed frame and rest frame velocities (such as might need to be done when using some software which by default will measure observed frame widths in terms of optical velocity), or similarly between observed frame and rest frame frequency widths, this can be done using

(21) $$\begin{eqnarray} \Delta V_{\rm rest} &=& \frac{1}{1+z}\Delta V_{\rm obs} , \end{eqnarray}$$
(22) $$\begin{eqnarray} \Delta \nu _{\rm obs} &=& \frac{1}{1+z}\Delta \nu _{\rm rest} . \end{eqnarray}$$

As a trivial extension, Equation (20) can also be used to determine the rest frame velocity resolution for a fixed observed frame channel width (setting Δνobs = Δνchan).

7 BEAM

For a normalised beam sensitivity response that can be represented as a 2D elliptical gaussian (and ignoring position angle),

(23) $$\begin{eqnarray} P_{\rm n}(x,y) = e^{-\left(\frac{x^{2}}{2\sigma _{x}^{2}} + \frac{y^{2}}{2\sigma _{y}^{2}}\right)} , \end{eqnarray}$$

the solid angle covered by the beam, or its field of view, is given by (e.g. Kraus Reference Kraus1986)

(24) $$\begin{eqnarray} \Omega _{\rm bm} &=& \int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty } P_{\rm n}(x,y)\, {d}x {d}y , \end{eqnarray}$$
(25) $$\begin{eqnarray} &=& 2\pi \sigma _{x}\sigma _{y} ,\hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty,, }} \end{eqnarray}$$
(26) $$\begin{eqnarray} &=& \frac{\pi ab}{4\ln (2)} . \hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty,, }} \end{eqnarray}$$

where a ( $= 2\sqrt{2\ln (2)}\sigma _{x}$ ) is the beam angular major axis, and b ( $= 2\sqrt{2\ln (2)} \sigma _{y}$ ) is the angular minor axis, both measured at the half power point.

Note that the half power points a, b∝λobs∝(1 + z), so for a synthesised beam with no frequency-dependent weighting, or a non-compound primary beam, the beam solid angle will vary as

(27) $$\begin{eqnarray} \Omega _{\rm bm}(z) &= (1+z)^{2}\Omega _{\rm bm}(0) . \end{eqnarray}$$

Note that in practice, the illumination of a telescope is frequency dependent, so the primary beam field of view may not scale exactly as (1 + z)2 as given above. A broadband feed will generally under-illuminate a dish at the highest frequencies, making the beam larger (and the efficiency lower).

Another useful metric is the ‘noise-equivalent field of view’ of a primary beam, or the equivalent solid angle sampled at full sensitivity, which is the integral of the square of the beam. This is relevant, for instance, when calculating the number of pointings needed to achieve a given noise sensitivity over an extended region of sky. For a normalised beam response represented by a 2D elliptical gaussian, this gives

(28) $$\begin{eqnarray} \Omega ^{\rm NE}_{\rm bm} &=& \int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty } P^{2}_{\rm n}(x,y)\, {d}x{ d}y , \end{eqnarray}$$
(29) $$\begin{eqnarray} &=& \pi \sigma _{x}\sigma _{y} ,\hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty,,,,,, }} \end{eqnarray}$$
(30) $$\begin{eqnarray} &=& \frac{\pi ab}{8\ln (2)} . \hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty,,,,, }} \end{eqnarray}$$

8 FLUX DENSITY

The observed flux density, S ν, for a source with a rest frame luminosity density of L νrest = L (1 + zobs = L (1 + z will be (Peacock Reference Peacock1999)

(31) $$\begin{eqnarray} S_{\nu } = (1+z)\frac{L_{(1+z)\nu }}{4\pi D_{L}^{2}} . \end{eqnarray}$$

The preferred unit for S ν is Jy (= 10−26 W m−2 Hz−1). The maximum of S ν for a given source is often referred to an object’s ‘peak’ flux density.

As a side note, the intensity scale of H i images is usually presented in units of ‘Jy per beam’, reflecting the fact that a telescope will measure any flux within its beam when pointed a source, i.e. that the specific intensity observed, I obs ν, is the real specific intensity at the location of the observer, I ν, convolved with the normalised beam, P n. The flux density, S ν of the source is then given by Kraus (Reference Kraus1986):

(32) $$\begin{eqnarray} S_{\nu } &=& \int _{\Omega _{\rm src}} I_{\nu }(\theta ,\phi ) \,{d}\Omega ,\hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty,,,,,,,,,,,,, }} \end{eqnarray}$$
(33) $$\begin{eqnarray} &=& \frac{1}{\Omega _{\rm bm}}\int _{\Omega _{\rm src}} I_{\nu }(\theta ,\phi ) \ast P_{\rm n}(\theta ,\phi ) \,{d}\Omega , \end{eqnarray}$$
(34) $$\begin{eqnarray} &=& \frac{1}{\Omega _{\rm bm}}\int _{\Omega _{\rm src}} I_{\nu }^{\rm obs}(\theta ,\phi )\,{d}\Omega . \hphantom{\int ^{\infty }_{-\infty }\int ^{\infty }_{-\infty }} \end{eqnarray}$$

To recover the correct flux for an extended region, ∫Ωsrc I obs ν(θ, ϕ) dΩ is measured by summing values of the pixels in the source region (in Jy per beam) multiplied by the pixel area, from which S ν can then recovered by dividing by the area of the beam. Or expressed alternatively, S ν can be measured by simply converting the specific intensity values of the image to Jy per pixel, and then summing over the region of interest.

Note that if the ratio of beam area to pixel area is constant as a function of frequency (i.e. both pixel area and beam area are scaling as 1 + z), then the correction factor for the extended source flux sum will be constant, but if not, e.g. the image cube has a fixed angular pixel sale, a varying correction will be required.

For a point source, while this approach could also be taken, it results in a sub-optimal signal-to-noise measurement compared to either just taking the value of the pixel centred on the source (although this has the potential to underestimate the source flux if the pixel is not exactly centred on the source), or weighting the pixel values by the beam response (which avoids this problem, but increases the effective angular area over which the measurement is being made compared to the single pixel method, and as such can increase the impact of source confusion).

9 FLUX

For a source at redshift z, with a rest frame total H i luminosity of L, its observed flux S will be

(35) $$\begin{eqnarray} S &=& \int S_{\nu } {d}\nu _{\rm obs} , \hphantom{\frac{L_{\nu _{\rm rest}}}{4\pi D_{L}^{2}} \text{d}\nu _{\rm obs}} \end{eqnarray}$$
(36) $$\begin{eqnarray} &=& \int (1+z)\frac{L_{\nu _{\rm rest}}}{4\pi D_{L}^{2}} {d}\nu _{\rm obs} , \end{eqnarray}$$
(37) $$\begin{eqnarray} &=& \int \frac{L_{\nu _{\rm rest}}}{4\pi D_{L}^{2}} {d}\nu _{\rm rest} , \hphantom{\frac{L_{\nu _{\rm rest}}}{4\pi D_{L}^{2}}} \end{eqnarray}$$
(38) $$\begin{eqnarray} \Rightarrow S &=& \frac{L}{4\pi D_{L}^{2}} . \hphantom{\frac{L_{\nu _{\rm rest}}}{4\pi D_{L}^{2}} \text{d}\nu _{\rm obs} \text{d} \text{d} \text{d} \text{d} \text{d} \text{d}} \end{eqnarray}$$

The preferred unit for this quantity is Jy Hz (= 10−26 W m−2). In H i studies, reference is often made to a similar, but dimensionally different quantity defined as the integral of flux density as a function of velocity rather than frequency:

(39) $$\begin{eqnarray} S^{V} = \int S_{\nu } {d}V , \end{eqnarray}$$

the units for which are Jy km s−1 (= 10−26 W m−2Hz−1 km s−1). This is a poor quantity for cosmological measurements as it introduces some uncertainty about exactly what velocity (or pseudo-velocity) has been used in its calculation, as discussed earlier. It is preferable to use S rather than S V wherever possible, and particularly so if referring to a measurement of an object’s observed total flux given the dimensional difference of S V from that of a natural flux value.

The conversion between S and S V depends on the velocity convention used. If S V is measured in the optical observed frame,

(40) $$\begin{eqnarray} \left( \frac{S^{V_{\rm obs}}}{\rm Jy\, km\, s^{-1}} \right) &=& \frac{c(1+z)^{2}}{\nu _{\textnormal {{H{\sc \,i}}}}} \left( \frac{S}{\rm Jy\, Hz} \right) , \end{eqnarray}$$
(41) $$\begin{eqnarray} \quad \simeq & 2.11\times 10^{-4} \left(1+z\right)^{2} \left( \frac{S}{\rm Jy\, Hz} \right) . \end{eqnarray}$$

Alternatively, if the velocity used for the calculation of S V is a source rest frame velocity (for which V optV SR at the velocities relevant for galaxy rotation), then

(42) $$\begin{eqnarray} \left( \frac{S^{V_{\rm rest}}}{\rm Jy\, km\, s^{-1}} \right) &=& \frac{c(1+z)}{\nu _{\textnormal {{H{\sc \,i}}}}} \left( \frac{S}{\rm Jy\, Hz} \right) , \end{eqnarray}$$
(43) $$\begin{eqnarray} \quad\simeq & 2.11\times 10^{-4} \left(1+z\right) \left( \frac{S}{\rm Jy\, Hz} \right) . \end{eqnarray}$$

10 NUMBER OF H i ATOMS

Taking $\frac{3}{4}$ of H i atoms to be in the upper hyperfine state, with a spontaneous emission rate of $A_{\textnormal {{H{\sc \,i}}}}$ , an emitted photon energy of $h\nu _{\textnormal {{H{\sc \,i}}}}$ , and an H i source with luminosity L to be optically thin, the number of H i atoms, ${\mathscr N}_{\textnormal {{H{\sc \,i}}}}$ , will be given by

(44) $$\begin{eqnarray} \mathscr {N}_{\textnormal {{H{\sc \,i}}}} = \frac{L}{\frac{3}{4} h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}}} , \hphantom{\frac{S}{\rm Jy\, Hz}} \end{eqnarray}$$
(45) $$\begin{eqnarray} = \frac{16\pi D_{L}^{2}S}{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}}} , \end{eqnarray}$$
(46) $$\begin{eqnarray} \Rightarrow \left( \frac{\mathscr {N}_{\textnormal {{H{\sc \,i}}}}}{h_{\rm C}^{-2}}\right) \simeq 5.91\times 10^{58} \left( \frac{D_{L}}{h_{\rm C}^{{-1}}\rm Mpc} \right)^{2} \left( \frac{S}{\rm Jy\, Hz} \right) . \end{eqnarray}$$

11 H i MASS

Using the above relation, the H i mass of a source is trivially given by (caveat corrections that need to be applied if the source is not optically thin)

(47) $$\begin{eqnarray} M_{\textnormal {{H{\sc \,i}}}} &=& \mathscr {N}_{\textnormal {{H{\sc \,i}}}}m_{\rm H} , \end{eqnarray}$$
(48) $$\begin{eqnarray} \Rightarrow \left( \frac{M_{\textnormal {{H{\sc \,i}}}}}{h_{\rm C}^{-2}\text{M}_{\odot }} \right) &\simeq & 49.7 \, \left( \frac{D_L}{h_{\rm C}^{-1}\rm Mpc} \right)^{2 }\left( \frac{S}{\rm Jy\, Hz} \right) , \end{eqnarray}$$

which compares to the relation expressed in terms of traditional observed frame velocity integrated flux:

(49) $$\begin{eqnarray} \left( \frac{M_{\textnormal {{H{\sc \,i}}}}}{h_{\rm C}^{-2}\text{M}_{\odot }} \right) \simeq \frac{2.35 \times 10^{5}}{(1+z)^{2}} \left( \frac{D_L}{h_{\rm C}^{-1}\rm Mpc} \right)^{2 }\left( \frac{S^{V_{\rm obs}}}{\rm Jy\, km\, s^{-1}} \right), \end{eqnarray}$$

or rest frame velocity integrated flux:

(50) $$\begin{eqnarray} \left( \frac{M_{\textnormal {{H{\sc \,i}}}}}{h_{\rm C}^{-2}\text{M}_{\odot }} \right) \simeq \frac{2.35 \times 10^{5}}{1+z} \left( \frac{D_L}{h_{\rm C}^{-1}\rm Mpc} \right)^{2 }\left( \frac{S^{V_{\rm rest}}}{\rm Jy\, km\, s^{-1}} \right). \end{eqnarray}$$

12 H i MASS FUNCTION

The H i mass function, $\Theta (M_{\textnormal {{H{\sc \,i}}}})$ , gives the number of sources per unit volume as a function of H i mass, i.e. the volume density of sources, n, having masses between M1 and M2 will be given by

(51) $$\begin{eqnarray} n = \int _{\hat{M}1}^{\hat{M}2} \Theta (\hat{M}_{\textnormal {{H{\sc \,i}}}}){d}\hat{M}_{\textnormal {{H{\sc \,i}}}} , \end{eqnarray}$$

where for convenience in the equations that follow, we have expressed this in terms of dimensionless mass $\hat{M}_{\textnormal {{H{\sc \,i}}}}\equiv M_{\textnormal {{H{\sc \,i}}}}/M_{\textnormal {{H{\sc \,i}}}}^{*}$ , $M_{\textnormal {{H{\sc \,i}}}}^{*}$ being one of the Schechter function parameters traditionally used to parameterise the mass function. Clearly, the mass function could also be expressed without this change of variable. The Schechter function form is given by (Schechter Reference Schechter1976; Zwaan et al. Reference Zwaan, Meyer, Staveley-Smith and Webster2005)

(52) $$\begin{eqnarray} \Theta (\hat{M}_{\textnormal {{H{\sc \,i}}}}){d}\hat{M}_{\textnormal {{H{\sc \,i}}}} = \theta ^{*} \hat{M}_{\textnormal {{H{\sc \,i}}}}^{\alpha } \text{e}^{-\hat{M}_{\textnormal {{H{\sc \,i}}}}} {d}\hat{M}_{\textnormal {{H{\sc \,i}}}} , \end{eqnarray}$$

where θ* provides the overall normalisation, α gives the slope of the low mass power-law, and $M_{\textnormal {{H{\sc \,i}}}}^{*}$ gives the characteristic turnover mass, above which the number of sources exponentially declines. Alternatively, the number of sources is often expressed as an integral over $\log (\hat{M}_{\textnormal {{H{\sc \,i}}}})$ rather than $\hat{M}_{\textnormal {{H{\sc \,i}}}}$ , i.e.

(53) $$\begin{eqnarray} n = \int _{\log (\hat{M}1)}^{\text{log}(\hat{M}2)} \Phi (\hat{M}_{\textnormal {{H{\sc \,i}}}}){d} \log \hat{M}_{\textnormal {{H{\sc \,i}}}} , \end{eqnarray}$$

which gives (Springob, Haynes, & Giovanelli Reference Springob, Haynes and Giovanelli2005; Martin et al. Reference Martin, Papastergis, Giovanelli, Haynes, Springob and Stierwalt2010)

(54) $$\begin{eqnarray} \Phi (\hat{M}_{\textnormal {{H{\sc \,i}}}}){d}\log \hat{M}_{\textnormal {{H{\sc \,i}}}} = \phi ^{*} \ln (10) \hat{M}_{\textnormal {{H{\sc \,i}}}}^{\alpha +1} e^{-\hat{M}_{\textnormal {{H{\sc \,i}}}}} {d}\log \hat{M}_{\textnormal {{H{\sc \,i}}}}. \end{eqnarray}$$

In practice, the H i mass function is normally presented as log (Φ) vs. $\log (\hat{M}_{\textnormal {{H{\sc \,i}}}})$ . In this space, the functional form of the Schechter function is given by

(55) $$\begin{eqnarray} \log \Phi = \log (\phi ^{*}\ln 10) + (1+\alpha )\log \hat{M}_{\textnormal {{H{\sc \,i}}}} - \hat{M}_{\textnormal {{H{\sc \,i}}}} \log ({e}). \end{eqnarray}$$

For evolutionary studies, the mass function is best expressed in comoving coordinates to remove normalisation changes caused purely by the expansion of the Universe.

Note also that the Schechter form of the H i mass function is not consistently defined in the literature, and so you may need to pay attention to the particular definition used when comparing results.

13 COSMOLOGICAL MASS DENSITY

The cosmological mass density of H i can be calculated by carrying out the mass-weighted integral over the H i mass function:

(56) $$\begin{eqnarray} \rho _{\textnormal {{H{\sc \,i}}}} &=& \int _{0}^{\infty } M_{\textnormal {{H{\sc \,i}}}} \Theta (M_{\textnormal {{H{\sc \,i}}}}){d}M_{\textnormal {{H{\sc \,i}}}} . \end{eqnarray}$$

This can either be simply summed directly from the measured H i mass function data points (providing a sufficient mass range is spanned and making sure to correct Θ values to those appropriate for the $\log M_{\textnormal {{H{\sc \,i}}}}$ binwidths actually used), or through the following analytic solution expressed in terms of the fitted Schechter parameters and the complete Gamma function, Γ (Zwaan et al. Reference Zwaan2003):

(57) $$\begin{eqnarray} \left(\frac{\rho _{\textnormal {{H{\sc \,i}}}}}{h_{\rm C}\, \text{M}_{\odot }\, {\rm Mpc}^{-3}}\right) =& \nonumber \\ \left(\frac{\theta ^{*}}{h_{\rm C}^{3}\,{\rm Mpc}^{-3}}\right)& \Gamma (2+\alpha )\left( \frac{M_{\textnormal {{H{\sc \,i}}}}^{*}}{h_{\rm C}^{-2}\text{M}_{\odot }}\right) . \end{eqnarray}$$

For an H i mass function measured using comoving volume, this will similarly yield a cosmic H i density in comoving coordinates, and so $\rho _{\textnormal {{H{\sc \,i}}}}$ should remain constant with redshift/lookback time if no evolution is occurring aside from the expansion of the Universe.

The cosmic mass density of H i can also be expressed as a fraction of the critical mass density:

(58) $$\begin{eqnarray} \Omega _{\textnormal {{H{\sc \,i}}}}(z) = \frac{\rho _{\textnormal {{H{\sc \,i}}}}(z)}{\rho _{\rm crit}(z)} , \end{eqnarray}$$

where in proper (physical) coordinates ρcrit(z) is given by

(59) $$\begin{eqnarray} \rho _{\rm crit}^{p}(z) = \frac{3H^{2}(z)}{8\pi G} , \end{eqnarray}$$

or in comoving coordinates:

(60) $$\begin{eqnarray} \rho _{\rm crit}^{c}(z) = \frac{1}{(1+z)^{3}}\frac{3H^{2}(z)}{8\pi G} . \end{eqnarray}$$

Evaluating these expressions for $\Omega _{\textnormal {{H{\sc \,i}}}}$ gives

(61) $$\begin{eqnarray} \left( \frac{\Omega _{\textnormal {{H{\sc \,i}}}}(z)}{h_{\rm C}^{-1}} \right) &=& \left( \frac{3.60 \times 10^{-8} \times H^{-2}(z)}{h_{\rm C}^{-2} \text{M}_{\odot }^{-1}{\rm Mpc}^{3}} \right) \nonumber \\ &&\times \left( \frac{\rho _{\textnormal {{H{\sc \,i}}}}^{p}(z)}{h_{\rm C} \text{M}_{\odot } {\rm Mpc}^{-3}} \right) , \end{eqnarray}$$

or

(62) $$\begin{eqnarray} &&\left( \frac{\Omega _{\textnormal {{H{\sc \,i}}}}(z)}{h_{\rm C}^{-1}} \right) \nonumber \\ &&\quad= \frac{1}{(1+z)^{3}}\left( \frac{3.60 \times 10^{-8} \times H^{-2}(z)}{h_{\rm C}^{-2} \text{M}_{\odot }^{-1}{\rm Mpc}^{3}} \right) \left( \frac{\rho _{\textnormal {{H{\sc \,i}}}}^{c}(z)}{h_{\rm C} \text{M}_{\odot } {\rm Mpc}^{-3}} \right) . \nonumber \\ \end{eqnarray}$$

Note that for an expanding Universe, if there exist contributors to the total energy density other than matter, ρ c crit will evolve with redshift along with ρ p crit. As such, $\Omega _{\textnormal {{H{\sc \,i}}}}$ will also change, even if the comoving density of H i does not. To remove this effect, the practice is often used of replacing ρcrit(z) with ρcrit(z = 0) in the above expressions, i.e.

(63) $$\begin{eqnarray} \Omega _{\textnormal {{H{\sc \,i}}}}(z) = \frac{\rho _{\textnormal {{H{\sc \,i}}}}(z)}{\rho _{\rm crit}(z=0)} , \end{eqnarray}$$

which also offers the convenience of ρ p crit(z = 0) = ρcrit c (z = 0), but be aware of the difference between this and the above derivations, and be sure to specify which definition of $\Omega _{\textnormal {{H{\sc \,i}}}}(z)$ is being used.

14 BRIGHTNESS TEMPERATURE

The brightness temperature corresponding to an observed flux density S ν, measured within a beam solid angle Ωbm, is the blackbody temperature an extended object would need to have to produce the observed flux in the Rayleigh-Jeans limit (hν ≪ kT; Wilson, Rohlfs, & Hüttemeister Reference Wilson, Rohlfs and Hüttemeister2009). From the Rayleigh-Jeans law, the luminosity emitted by a blackbody per unit area into a unit solid angle, B ν is given by

(64) $$\begin{eqnarray} B_{\nu } = \frac{2 k \nu ^{2} T}{c^{2}} , \end{eqnarray}$$

where k is Boltzmann’s constant. In a Euclidean geometry, I ν = B ν (surface brightness conservation; I ν is the received specific intensity), giving the traditional local-Universe relation for H i brightness temperature:

(65) $$\begin{eqnarray} B_{\nu } &=& I_{\nu } = \frac{S_{\nu }}{\Omega _{\rm bm}} = \frac{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2} T}{c^{2}} , \end{eqnarray}$$
(66) $$\begin{eqnarray} \Rightarrow T_{\rm B} &=& \frac{c^{2} S_{\nu }}{2k\nu _{\textnormal {{H{\sc \,i}}}}^{2}\Omega _{\rm bm}} . \end{eqnarray}$$

However, in a relativistic Universe, we have (Peacock Reference Peacock1999)

(67) $$\begin{eqnarray} I_{\nu } &=& \frac{B_{\nu (1+z)}}{(1+z)^{3}} = \frac{B_{\nu _{\rm rest}}}{(1+z)^{3}} , \end{eqnarray}$$

giving

(68) $$\begin{eqnarray} I_{\nu } = \frac{S_{\nu }}{\Omega _{\rm bm}} = \frac{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2}T}{c^{2}(1+z)^{3}} , \end{eqnarray}$$
(69) $$\begin{eqnarray} \Rightarrow T_{\rm B} = (1+z)^{3}\frac{c^{2}S_{\nu }}{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2}\Omega _{\rm bm}} . \hphantom{\frac{S_{\nu }}{1}} \end{eqnarray}$$

Evaluating the constants gives

(70) $$\begin{eqnarray} \left( \frac{T_{\rm B}}{K} \right) = 6.86 \times 10^{5} \left( 1+ z \right)^{3} \left( \frac{S_{\nu }}{\rm Jy} \right)\left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}} \right)^{-1} \!\!\!\!\!\!, \end{eqnarray}$$

or expressed alternatively as a function of the beam angular major and minor axes a and b:

(71) $$\begin{eqnarray} \left( \frac{T_{\rm B}}{K} \right) = 6.06 \times 10^{5} \left( 1+ z \right)^{3} \left( \frac{S_{\nu }}{\rm Jy} \right)\left( \frac{ab}{\rm arcsec^{2}} \right)^{-1} \!\!\!\!\!\!. \end{eqnarray}$$

15 COLUMN DENSITY

The H i column density gives the number of atoms per unit area along the line of sight through an astronomical object. The column density $N_{\textnormal {{H{\sc \,i}}}}$ for a flux S measured in solid angle Ωbm is given by (using Equation (45) for the number of atoms, and the small angle approximation to calculate the source area; material is again assumed to be optically thin)

(72) $$\begin{eqnarray} N_{\textnormal {{H{\sc \,i}}}} &=& \frac{\mathscr {N}_{\textnormal {{H{\sc \,i}}}}}{\rm area} = \left( \frac{16\pi D_{L}^{2}S}{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}}} \right)\left( \frac{1}{D_{A}^{2}\Omega _{\rm bm}} \right), \end{eqnarray}$$
(73) $$\begin{eqnarray} &=& \frac{16\pi }{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}}} (1+z)^{4} \frac{S}{\Omega _{\rm bm}},\hphantom{\frac{S_{\nu }}{1}\frac{S_{\nu }}{1}} \end{eqnarray}$$
(74) $$\begin{eqnarray} \Rightarrow \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) = 2.64 \times 10^{20} (1+z)^{4}\left(\frac{S}{\rm JyHz} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} ,\nonumber\\ \end{eqnarray}$$

or in terms of the beam angular major and minor axes a and b:

(75) $$\begin{eqnarray} N_{\textnormal {{H{\sc \,i}}}} &=& \left( \frac{16\pi D_{L}^{2}S}{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}}} \right)\left( \frac{4\ln (2)}{D_{A}^{2}\pi ab } \right) , \hphantom{\frac{S_{\nu }}{1}\frac{S_{\nu }}{1}\frac{S_{\nu }}{1}} \end{eqnarray}$$
(76) $$\begin{eqnarray} \Rightarrow \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) = 2.33 \times 10^{20} (1+z)^{4}\left(\frac{S}{\rm JyHz} \right) \left( \frac{ab}{\rm arcsec^{2}}\right)^{-1} .\nonumber\\ \end{eqnarray}$$

For comparison, the expressions in terms of observed frame velocity integrated flux are

(77) $$\begin{eqnarray} \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) &=& 1.25 \times 10^{24} (1+z)^{2} \hphantom{(1+z)(1+z)}\nonumber\\ && \times \left(\frac{S^{V_{\rm obs}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1}, \end{eqnarray}$$
(78) $$\begin{eqnarray} \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) &=& 1.10 \times 10^{24} (1+z)^{2}\hphantom{(1+z)(1+z)} \nonumber\\ && \times \left( \frac{S^{V_{\rm obs}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{ab}{\rm arcsec^{2}}\right)^{-1}. \end{eqnarray}$$

And for rest frame velocity integrated flux:

(79) $$\begin{eqnarray} \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) &=& 1.25 \times 10^{24} (1+z)^{3} \hphantom{(1+z)(1+z)}\nonumber\\ && \times \left( \frac{S^{V_{\rm rest}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1}, \end{eqnarray}$$
(80) $$\begin{eqnarray} \left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) &=& 1.10 \times 10^{24} (1+z)^{3} \nonumber\\ && \times \left( \frac{S^{V_{\rm rest}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{ab}{\rm arcsec^{2}}\right)^{-1}. \end{eqnarray}$$

The above column density expressions can be readily expressed as H i surface mass densities by multiplying m H and converting to the desired units, e.g.

(81) $$\begin{eqnarray} \left(\frac{\Sigma _{\rm H\,{\textsc {i}}}}{\rm M_{\odot }\, pc^{-2}}\right) &=& 8.01 \times 10^{-21}\left(\frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}}\right) , \hphantom{\left(\frac{\Sigma _{\rm H\,{\textsc {i}}}}{\rm M_{\odot }\, pc^{-2}}\right)0000} \end{eqnarray}$$
(82) $$\begin{eqnarray} \hphantom{000000}&=& 2.12 \,\, (1+z)^{4}\left(\frac{S}{\rm JyHz} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1}, \end{eqnarray}$$
(83) $$\begin{eqnarray} &=& 1.00 \times 10^{4} (1+z)^{2} \nonumber\\ &&\times \left( \frac{S^{V_{\rm obs}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1}, \end{eqnarray}$$
(84) $$\begin{eqnarray} &=& 1.00 \times 10^{4} (1+z)^{3} \nonumber\\ && \times \left( \frac{S^{V_{\rm rest}}}{\rm Jy\, km\, s^{-1}} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1}. \end{eqnarray}$$

Column density can also be expressed as a function of brightness temperature, T B. Following Wilson et al. (Reference Wilson, Rohlfs and Hüttemeister2009), Giovanelli & Haynes (Reference Giovanelli, Haynes, Verschuur and Kellermann1988), and Brinks (Reference Brinks, Thronson and Shull1990), for a cloud with spin temperature T S and optical depth τ embedded in a radiation field having brightness temperature T R, its brightness temperature, T B, will be given by

(85) $$\begin{eqnarray} T_{\rm B} = T_{\rm R} e^{-\tau _{\nu }} + T_{\rm S}(1-e^{-\tau _{\nu }}) . \end{eqnarray}$$

If the cloud is optically thin (τ ≪ 1), and assuming that background radiation field has negligible impact, then

(86) $$\begin{eqnarray} T_{\rm B} = \tau _{\nu } T_{\rm S} . \end{eqnarray}$$

The optical depth per unit frequency can be related to the density of hydrogen atoms per unit length along the line of sight:

(87) $$\begin{eqnarray} {d}\tau _{\nu } = - \frac{3c^{2}}{32\pi \nu _{\textnormal {{H{\sc \,i}}}}}A_{\textnormal {{H{\sc \,i}}}} n_{\textnormal {{H{\sc \,i}}}}\frac{h}{kT_{\rm s}}\phi (\nu ) {d}l , \end{eqnarray}$$

where $n_{\textnormal {{H{\sc \,i}}}}$ refers to the volume density of hydrogen atoms, and ϕ is the line shape function reflecting the natural line width (∫ϕ(ν)dν = 1). Integrating this over ν and s gives

(88) $$\begin{eqnarray} \int n_{\textnormal {{H{\sc \,i}}}} {d}l = \frac{32\pi k \nu _{\textnormal {{H{\sc \,i}}}}}{3A_{\textnormal {{H{\sc \,i}}}}hc^{2}} T_{\rm s} \int \tau _{\nu }{d}\nu . \end{eqnarray}$$

The left-hand side of this expression is the desired H i column density $N_{\textnormal {{H{\sc \,i}}}} = \int n_{\textnormal {{H{\sc \,i}}}} {d}l$ , while the right-hand side can now be written as a function of brightness temperature using Equation (86):

(89) $$\begin{eqnarray} N_{\textnormal {{H{\sc \,i}}}} &=& \frac{32\pi k \nu _{\textnormal {{H{\sc \,i}}}}}{3A_{\textnormal {{H{\sc \,i}}}}hc^{2}} \int T_{\rm B} {d}\nu _{\rm rest} , \hphantom{0} \end{eqnarray}$$
(90) $$\begin{eqnarray} \Rightarrow \left( \frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}} \right) &=& 3.85 \times 10^{20} \int \left( \frac{T_{\rm B}}{\it K} \right) \left( \frac{{d}\nu _{\rm rest}}{\rm MHz} \right) \!. \end{eqnarray}$$

Note that the frequency integral here is in the source rest frame. As both $N_{\textnormal {{H{\sc \,i}}}}$ and T B are also rest frame quantities, there are no (1 + z) factors in the above expression. Alternatively, Equation (89) can also be expressed as an integral over rest frame velocity:

(91) $$\begin{eqnarray} N_{\textnormal {{H{\sc \,i}}}} &=& \frac{32\pi k \nu _{\textnormal {{H{\sc \,i}}}}^{2}}{3A_{\textnormal {{H{\sc \,i}}}}hc^{3}} \int T_{\rm B} {d}V_{\rm rest} ,\hphantom{00} \end{eqnarray}$$
(92) $$\begin{eqnarray} \Rightarrow \left( \frac{N_{\textnormal {{H{\sc \,i}}}}}{\rm cm^{-2}} \right) &=& 1.82 \times 10^{18} \int \left( \frac{T_{\rm B}}{\it K}\right) \left( \frac{{d}V_{\rm rest}}{\rm km\ s^{-1}} \right) \!. \end{eqnarray}$$

To recover the previous expression for H i column density (Equation (73)), Equations (69) and (89) give

(93) $$\begin{eqnarray} N_{\textnormal {{H{\sc \,i}}}} &=& \frac{32\pi k \nu _{\textnormal {{H{\sc \,i}}}}}{3A_{\textnormal {{H{\sc \,i}}}}hc^{2}} \int (1+z)^{3}\frac{c^{2}S_{\nu }}{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2}\Omega _{\rm bm}} {d}\nu _{\rm rest}, \hphantom{.} \end{eqnarray}$$
(94) $$\begin{eqnarray} &=& \frac{16\pi }{3h\nu _{\textnormal {{H{\sc \,i}}}}A_{\textnormal {{H{\sc \,i}}}}}(1+z)^{4}\frac{1}{\Omega _{\rm bm}} \int S_{\nu } {d}\nu _{\rm obs} , \end{eqnarray}$$
(95) $$\begin{eqnarray} &=& \frac{16\pi }{3h\nu _{\textnormal {{H{\sc \,i}}}}A_{\textnormal {{H{\sc \,i}}}}}(1+z)^{4}\frac{S}{\Omega _{\rm bm}} \hspace{2.84526pt}\mbox{, as before.} \end{eqnarray}$$

16 FLUX AND FLUX DENSITY SENSITIVITY

If not known observationally, the flux density sensitivity of a single-pointing, naturally weighted, Stokes-I, non-primary beam corrected interferometric image can be estimated using (Taylor, Carilli, & Perley Reference Taylor, Carilli and Perley2008; Kraus Reference Kraus1986; Obreschkow, Heywood, & Rawlings Reference Obreschkow, Heywood and Rawlings2011)

(96) $$\begin{eqnarray} \sigma _{S_{\nu }} &=& \frac{\text{SEFD}}{\eta _{\rm s}\sqrt{2 N(N-1)\Delta t \Delta \nu }} , \hphantom{000.} \end{eqnarray}$$
(97) $$\begin{eqnarray} &=& \frac{k T_{\rm sys}}{\eta _{\rm s}A_{\rm e}} \sqrt{\frac{2}{N(N-1)\Delta t \Delta \nu }} , \end{eqnarray}$$

where SEFD is the System Equivalent Flux Density of an antenna in the array (=2kT sys/A e; assumed to be the same for all elements in the above relation), Δν is the frequency width of interest, Δt is the integration time, T sys is the system temperature, N is the number of antennas, A e is the effective area of each antenna, ηs is the system efficiency, and k is Boltzmann’s constant. It should be noted that in practice a number of factors may reduce the achieved observational sensitivity from the theoretical value above, such as the application of weighting and tapering. Evaluating the constants to give the sensitivity in Jy:

(98) $$\begin{eqnarray} \left(\frac{\sigma _{S_{\nu }}}{\rm Jy}\right) = \frac{1952.5}{\eta _{\rm s}\sqrt{N(N-1)}} \left(\frac{A_{\rm e}/T_{\rm sys}}{\rm m^{2} K^{-1}}\right)^{-1} \left(\frac{\Delta t}{\rm s}\right)^{-\frac{1}{2}} \left(\frac{\Delta \nu }{\rm Hz}\right)^{-\frac{1}{2}} .\nonumber\\ \end{eqnarray}$$

The corresponding flux sensitivity scaling is

(99) $$\begin{eqnarray} \sigma _{S} &=& \Delta \nu \, \sigma _{S_{\nu }} , \hphantom{000000000000000} \end{eqnarray}$$
(100) $$\begin{eqnarray} &=& \frac{\text{SEFD}}{\eta _{\rm s}} \sqrt{\frac{\Delta \nu }{2 N(N-1)\Delta t}} , \end{eqnarray}$$
(101) $$\begin{eqnarray} &=& \frac{k T_{\rm sys}}{\eta _{\rm s}A_{\rm e}} \sqrt{\frac{2\Delta \nu }{N(N-1)\Delta t}}, \hphantom{0.} \end{eqnarray}$$

or

(102) $$\begin{eqnarray} \left(\frac{\sigma _{S}}{\rm JyHz}\right) = \frac{1952.5}{\eta _{\rm s}\sqrt{N(N-1)}} \left(\frac{A_{\rm e}/T_{\rm sys}}{\rm m^{2} K^{-1}}\right)^{-1} \left(\frac{\Delta t}{\rm s}\right)^{-\frac{1}{2}} \left(\frac{\Delta \nu }{\rm Hz}\right)^{\frac{1}{2}}.\nonumber\\ \end{eqnarray}$$

Observationally, if the flux density sensitivity averaged over channel interval Δνchan is known, σ S νchan , the flux and flux density sensitivities over interval Δν can be simply calculated using

(103) $$\begin{eqnarray} \sigma _{S_{\nu }} &=& \sigma _{S_{\nu _{\rm chan}}}\sqrt{\frac{\Delta \nu _{\rm chan}}{\Delta \nu }} , \hphantom{00.} \end{eqnarray}$$
(104) $$\begin{eqnarray} \sigma _{S} &=& \sigma _{S_{\nu _{\rm chan}}}\sqrt{\Delta \nu _{\rm chan} \Delta \nu } . \end{eqnarray}$$

As observed frame quantities, these have no inherent scaling as a function of redshift, however telescope performance may be varying significantly as a function of frequency, often encoded as variations in the A e/T sys term of Equations (97) and (101) (and system efficiency ηs if desired), introducing a redshift scaling of

(105) $$\begin{eqnarray} \sigma _{S_{\nu }}(z) = f(z)\sigma _{S_{\nu }}(0) ,\hphantom{00.} \end{eqnarray}$$
(106) $$\begin{eqnarray} \sigma _{S}(z) = f(z)\sigma _{S}(0) , \hphantom{00.} \end{eqnarray}$$

where

(107) $$\begin{eqnarray} f(z) = \frac{\frac{\eta _{\rm s}A_{\rm e}}{T_{\rm sys}}(z=0) }{ \frac{\eta _{\rm s}A_{\rm e}}{T_{\rm sys}}(z) }. \end{eqnarray}$$

As will become apparent in the next sections concerning brightness temperature and column density sensitivity, it can also be useful to understand how these relations vary as a function of rest frame velocity interval ΔV rest. Substituting Equation (20) into Equations (103) and (104) gives

(108) $$\begin{eqnarray} \sigma _{S_{\nu }} = \sigma _{S_{\nu _{\rm chan}}}\sqrt{\frac{ c(1+z)\Delta \nu _{\rm chan}}{\nu _{\textnormal {{H{\sc \,i}}}}\Delta V_{\rm rest}}} ,\hphantom{0} \end{eqnarray}$$
(109) $$\begin{eqnarray} \sigma _{S} = \sigma _{S_{\nu _{\rm chan}}}\sqrt{\frac{\nu _{\textnormal {{H{\sc \,i}}}}\Delta V_{\rm rest}\Delta \nu _{\rm chan}}{c(1+z)}} , \end{eqnarray}$$

and a redshift scaling of (with A e/T sys variations):

(110) $$\begin{eqnarray} \sigma _{S_{\nu }}^{\Delta V_{\rm rest}^{\rm const}} (z) = f(z)(1+z)^{{\frac{1}{2}}} \sigma _{S_{\nu }}^{\Delta V_{\rm rest}^{\rm const}}(0) , \hphantom{0} \end{eqnarray}$$
(111) $$\begin{eqnarray} \sigma _{S}^{\Delta V_{\rm rest}^{\rm const}} (z) = f(z)(1+z)^{{-\frac{1}{2}}} \sigma _{S}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

Widefield single-beam mosaic:

For a widefield mosaic in which many overlapping primary beam pointings have been used to image a large area, an additional factor needs to be considered. For a fixed pointing pattern, the primary beam field of view for each pointing will also increase as Ωbm∝(1 + z)2, which will in turn lead to the noise decreasing in the mosaic as (1 + z)−1 (Abdalla & Rawlings Reference Abdalla and Rawlings2005), giving

(112) $$\begin{eqnarray} \bar{\sigma }_{S_{\nu }}(z) &=& f(z)(1+z)^{-1} \bar{\sigma }_{S_{\nu }}(0) , \end{eqnarray}$$
(113) $$\begin{eqnarray} \bar{\sigma }_{S} (z) &=& f(z)(1+z)^{-1} \bar{\sigma }_{S}(0) , \end{eqnarray}$$
(114) $$\begin{eqnarray} \bar{\sigma }_{S_{\nu }}^{\Delta V_{\rm rest}^{\rm const}} (z) &=& f(z)(1+z)^{{-\frac{1}{2}}} \bar{\sigma }_{S}^{\Delta V_{\rm rest}}(0) , \hphantom{.} \end{eqnarray}$$
(115) $$\begin{eqnarray} \bar{\sigma }_{S}^{\Delta V_{\rm rest}^{\rm const}} (z) &=& f(z)(1+z)^{{-\frac{3}{2}}} \bar{\sigma }_{S}^{\Delta V_{\rm rest}}(0) .\hphantom{.} \end{eqnarray}$$

Phased array feed observations:

For a phased array feed (PAF), the field of view will not necessarily increase as (1 + z)2 as in the single beam case above, due to correlated noise effects between adjacent formed beams. Indeed, once the central part of the field is fully sampled, ΩPAF will not continue to rise with redshift apart from some growth at the edges. Instead, we can redefine the generic scaling factor to include field-of-view effects, applying the same inverse square root scaling of this to derive the impact on observed noise in a surveyed area:

(116) $$\begin{eqnarray} f_{\rm PAF}(z) = \frac{\frac{\eta _{\rm s}A_{\rm e} {\Omega _{\rm PAF}}^{\frac{1}{2}} }{T_{\rm sys}}(z=0) }{ \frac{\eta _{\rm s}A_{\rm e} {\Omega _{\rm PAF}}^{\frac{1}{2}} }{T_{\rm sys}}(z) }, \hphantom{00.} \end{eqnarray}$$

to give

(117) $$\begin{eqnarray} \bar{\sigma }_{S_{\nu }}(z) &=& f_{\rm PAF}(z) \bar{\sigma }_{S_{\nu }}(0) , \hphantom{000000.} \end{eqnarray}$$
(118) $$\begin{eqnarray} \bar{\sigma }_{S} (z) &=& f_{\rm PAF}(z) \bar{\sigma }_{S}(0) , \hphantom{000000.} \end{eqnarray}$$
(119) $$\begin{eqnarray} \bar{\sigma }_{S_{\nu }}^{\Delta V_{\rm rest}^{\rm const}} (z) &=& f_{\rm PAF}(z) (1+z)^{{\frac{1}{2}}} \bar{\sigma }_{S}^{\Delta V_{\rm rest}}(0) , \hphantom{.} \end{eqnarray}$$
(120) $$\begin{eqnarray} \bar{\sigma }_{S}^{\Delta V_{\rm rest}^{\rm const}} (z) &=& f_{\rm PAF}(z) (1+z)^{{-\frac{1}{2}}} \bar{\sigma }_{S}^{\Delta V_{\rm rest}}(0) . \end{eqnarray}$$

17 BRIGHTNESS TEMPERATURE SENSITIVITY

The relativistically derived relation between brightness temperature and flux density (Equation (69)), gives a corresponding sensitivity relation of

(121) $$\begin{eqnarray} \sigma _{T_{\rm B}} &=& (1+z)^{3}\frac{c^{2}}{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2}\Omega _{\rm bm}} \sigma _{S_{\nu }} , \end{eqnarray}$$
(122) $$\begin{eqnarray} \nonumber\\[-32pt]\Rightarrow \left(\frac{\sigma _{T_{\rm B}}}{\it K}\right){= }6.86 \times 10^{5} \, (1+z)^{3} \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\frac{\sigma _{S_{\nu }}}{\rm Jy}\right) , \end{eqnarray}$$

which combining with the previous expression for flux density sensitivity (Equation (97)) yields

(123) $$\begin{eqnarray} \sigma _{T_{\rm B}} = (1+z)^{3} \frac{c^{2}T_{\rm sys}}{\nu _{\textnormal {{H{\sc \,i}}}}^{2}A_{e}\Omega _{\rm bm}} \frac{1}{\eta _{\rm s}\sqrt{2N(N-1)\Delta t \Delta \nu }}\phantom{0000000} , \end{eqnarray}$$
(124) $$\begin{eqnarray} &\Rightarrow \left(\displaystyle\frac{\sigma _{T_{\rm B}}}{\rm K}\right){=}\displaystyle\frac{1.34 \times 10^{9} \, (1+z)^{3}}{\eta _{\rm s}\sqrt{N(N-1)}}\hphantom{000000000000000} \nonumber \\ &\hphantom{0}\times \left(\displaystyle\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\displaystyle\frac{A_{\rm e}/T_{\rm sys}}{\rm m^{2} K^{-1}}\right)^{-1} \left(\displaystyle\frac{\Delta t}{\rm s}\right)^{-\frac{1}{2}} \left(\displaystyle\frac{\Delta \nu }{\rm Hz}\right)^{-\frac{1}{2}} . \end{eqnarray}$$

Using Equation (103), this can also be expressed as a function of the flux density sensitivity per channel σνchan (width Δνchan):

(125) $$\begin{eqnarray} \sigma _{T_{\rm B}} &=& (1+z)^{3} \frac{c^{2}}{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{2}\Omega _{\rm bm}} \sqrt{\frac{\Delta \nu _{\rm chan}}{\Delta \nu }}\sigma _{S_{\nu _{\rm chan}}} , \end{eqnarray}$$
(126) $$\begin{eqnarray} &\Rightarrow \left(\frac{\sigma _{T_{\rm B}}}{\rm K}\right) \,=\, 6.86 \times 10^{5} \, (1+z)^{3}\hphantom{0} \nonumber \\ &\hphantom{00}\times \sqrt{\displaystyle\frac{\Delta \nu _{\rm chan}}{\Delta \nu }} \left(\displaystyle\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\displaystyle\frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy}\right) . \end{eqnarray}$$

Or alternatively expressed per desired rest frame velocity interval ΔV rest rather than per observed frame frequency width using Equation (108):

(127) $$\begin{eqnarray} \sigma _{T_{\rm B}} &=& (1+z)^{7/2} \frac{c^{5/2}}{2 k \nu _{\textnormal {{H{\sc \,i}}}}^{5/2}\Omega _{\rm bm}} \sqrt{\frac{\Delta \nu _{\rm chan}}{\Delta V_{\rm rest}}} \sigma _{S_{\nu _{\rm chan}}} , \hphantom{000} \end{eqnarray}$$
(128) $$\begin{eqnarray} &\Rightarrow \left(\frac{\sigma _{T_{\rm B}}}{\it K}\right) \,= \, 9\,971 \, (1+z)^{\frac{7}{2}}\hphantom{00000000000} \nonumber \\ &\hphantom{0000000}\times \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\frac{\Delta \nu _{\rm chan}}{\rm Hz}\right)^{\frac{1}{2}} \left(\frac{\Delta V_{\rm rest}}{\rm km\,s^{-1}}\right)^{-\frac{1}{2}} \left(\frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy}\right) . \end{eqnarray}$$

In the instance of a comparison being made for observations with a given telescope at different redshifts, but where the configuration has been changed between observations to yield the same synthesised beam solid angle, this will give a redshift scaling relation of

(129) $$\begin{eqnarray} \sigma _{T_{\rm B}}(z) &=& f(z)(1+z)^{3} \sigma _{T_{\rm B}}(0) , \hphantom{0} \end{eqnarray}$$
(130) $$\begin{eqnarray} \sigma _{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(z) &=& f(z)(1+z)^{7/2} \sigma _{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(0) , \end{eqnarray}$$

where f(z) captures redshift variations in ηs A e/T sys as before (Equation (107)). If instead we now consider how the brightness temperature sensitivity will change for a fixed configuration observation across a range of frequencies, the synthesised beam solid angle will increase as Ωbm∝(1 + z)2 (ignoring frequency-dependent illumination effects) giving

(131) $$\begin{eqnarray} \sigma _{T_{\rm B}}(z) &=& f(z)(1+z) \sigma _{T_{\rm B}}(0) , \end{eqnarray}$$
(132) $$\begin{eqnarray} \sigma _{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(z) &=& f(z)(1+z)^{3/2} \sigma _{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

Taking these last equations as a starting point, we can also derive the redshift scaling equations for a widefield mosaic and for a PAF as per the previous section allowing for overlapping primary (formed-) beam effects:

Widefield single-beam mosaic:

(133) $$\begin{eqnarray} \bar{\sigma }_{T_{\rm B}}(z) &=& f(z) \bar{\sigma }_{T_{\rm B}}(0) , \hphantom{0000000} \end{eqnarray}$$
(134) $$\begin{eqnarray} \bar{\sigma }_{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(z) &=& f(z)(1+z)^{1/2} \bar{\sigma }_{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

Phased array feed observations:

(135) $$\begin{eqnarray} \bar{\sigma }_{T_{\rm B}}(z) &=& f_{\rm PAF}(z) (1+z) \bar{\sigma }_{T_{\rm B}}(0) ,\hphantom{0.} \end{eqnarray}$$
(136) $$\begin{eqnarray} \bar{\sigma }_{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(z) &=& f_{\rm PAF}(z) (1+z)^{3/2} \bar{\sigma }_{T_{\rm B}}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

18 COLUMN DENSITY SENSITIVITY

Taking the previous expression for column density in terms of flux and beam size (Equation (73)) gives the corresponding sensitivity relation of

(137) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}} &=& (1+z)^{4} \frac{16\pi }{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}} \Omega _{\rm bm}} \sigma _{S} , \hphantom{0000000000000.} \end{eqnarray}$$
(138) $$\begin{eqnarray} \Rightarrow \left(\frac{\sigma _{N_{\textnormal {{H{\sc \,i}}}}}}{\rm cm^{-2}}\right) &=& 2.64 \times 10^{20} \, (1+z)^{4} \\ \nonumber && \times \left(\frac{\sigma _S}{\rm JyHz} \right) \left( \frac{\Omega _{\rm bm}}{\rm arcsec^{2}} \right), \end{eqnarray}$$

and substituting in Equation (101) for a theoretical sensitivity estimates:

(139) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}} &=& (1+z)^{4} \frac{16\pi k T_{\rm sys}}{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}} \Omega _{\rm bm} \eta _{\rm s}A_{\rm e}} \\ \nonumber && \times \sqrt{\frac{2\Delta \nu }{N(N-1)\Delta t}} ,\hphantom{00000000000000000000000000000.} \end{eqnarray}$$
(140) $$\begin{eqnarray} &\Rightarrow& \left(\frac{\sigma _{N_{\textnormal {{H{\sc \,i}}}}}}{\rm cm^{-2}}\right)\,=\,\frac{5.15 \times 10^{23} \, (1+z)^{4}}{\eta _{\rm s}\sqrt{N(N-1)}}\nonumber \\ &&\times \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\frac{A_{\rm e}/T_{\rm sys}}{\rm m^{2} K^{-1}}\right)^{-1} \left(\frac{\Delta t}{\rm s}\right)^{-\frac{1}{2}} \left(\frac{\Delta \nu }{\rm Hz}\right)^{\frac{1}{2}} . \nonumber\\ \end{eqnarray}$$

Or from Equation (104), scaling from known channel noise:

(141) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}} &=& (1+z)^{4} \frac{16\pi \sqrt{\Delta \nu _{\rm chan} \Delta \nu }}{3 h\nu _{\textnormal {{H{\sc \,i}}}} A_{\textnormal {{H{\sc \,i}}}} \Omega _{\rm bm}} \sigma _{S_{\nu _{\rm chan}}} , \end{eqnarray}$$
(142) $$\begin{eqnarray} &\Rightarrow & \left(\frac{\sigma _{N_{\textnormal {{H{\sc \,i}}}}}}{\rm cm^{-2}}\right){=} 2.64 {\times } 10^{20} \, (1+z)^{4}\nonumber \\ &&\times \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\frac{\Delta \nu }{\rm Hz}\right)^{\frac{1}{2}} \left(\frac{\Delta \nu _{\rm chan}}{\rm Hz}\right)^{\frac{1}{2}} \left(\frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy}\right) . \end{eqnarray}$$

And finally as a function of rest frame velocity interval using Equation (109):

(143) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}} &=& (1+z)^{7/2} \frac{16\pi \sqrt{\Delta V_{\rm rest}\Delta \nu _{\rm chan}}}{3 h\nu _{\textnormal {{H{\sc \,i}}}}^{1/2} A_{\textnormal {{H{\sc \,i}}}} \Omega _{\rm bm}c^{1/2}} \sigma _{S_{\nu _{\rm chan}}} , \end{eqnarray}$$
(144) $$\begin{eqnarray} &&\nonumber\\[-32pt] &\Rightarrow& \left(\frac{\sigma _{N_{\textnormal {{H{\sc \,i}}}}}}{\rm cm^{-2}}\right){=} 1.82 {\times } 10^{22} \, (1+z)^{\frac{7}{2}}\nonumber \\ &&\times \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right)^{-1} \left(\frac{\Delta V_{\rm rest}}{\rm km\,s^{-1}}\right)^{\frac{1}{2}} \left(\frac{\Delta \nu _{\rm chan}}{\rm Hz}\right)^{\frac{1}{2}} \left(\frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy}\right) .\nonumber \\ \end{eqnarray}$$

Looking at the redshift scaling relations as before, we have for a changing configuration with fixed synthesised beam solid angle (with f(z) defined as before in Equation (107)):

(145) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}}(z) & = & f(z) (1+z)^{4} \,\, \sigma _{N_{\textnormal {{H{\sc \,i}}}}}(0) , \hphantom{0} \end{eqnarray}$$
(146) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}}(z) & = & f(z) (1+z)^{7/2} \,\, \sigma _{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

For a fixed configuration with synthesised beam solid angle increasing as (1 + z)2:

(147) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}}(z) & = & f(z) (1+z)^{2} \,\, \sigma _{{}N_{\textnormal {{H{\sc \,i}}}}}(0) , \hphantom{0} \end{eqnarray}$$
(148) $$\begin{eqnarray} \sigma _{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}} (z) & = & f(z) (1+z)^{3/2} \,\, \sigma _{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}} (0) . \end{eqnarray}$$

And finally for the widefield mosaic and PAF cases:

Widefield single-beam mosaic:

(149) $$\begin{eqnarray} \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}(z) & = & f(z) (1+z) \,\, \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}(0) , \hphantom{0.} \end{eqnarray}$$
(150) $$\begin{eqnarray} \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}} (z) & = & f(z) (1+z)^{1/2} \,\, \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}} (0) . \end{eqnarray}$$

Phased array feeds observations:

(151) $$\begin{eqnarray} \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}(z) & = & f_{\rm PAF}(z) (1+z)^{2} \,\, \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}(0) , \hphantom{0} \end{eqnarray}$$
(152) $$\begin{eqnarray} \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}} (z) & = & f_{\rm PAF}(z) (1+z)^{3/2} \,\, \bar{\sigma }_{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}^{\rm const}}(0) . \end{eqnarray}$$

19 SIGNAL-TO-NOISE

The significance of a measurement can be determined by simply taking the ratio of the observed quantity to the measured noise in that quantity over the same region. As such, the equations of the previous sections trivially lend themselves to predicting the likely outcomes of observations. A few of the most important are detailed below.

Peak signal-to-noise:

(153) $$\begin{eqnarray} S/N_{\rm peak} &=& \frac{S_{\rm \nu ,peak}}{\sigma _{S_{\nu _{\rm chan}}}} . \end{eqnarray}$$

Integrated signal-to-noise for a point source:

(154) $$\begin{eqnarray} S/N_{\rm int} &=& \frac{S}{\sigma _{S_{\nu _{\rm chan}}}\sqrt{\Delta \nu _{\rm chan} \Delta \nu }} ,\hphantom{00000} \end{eqnarray}$$
(155) $$\begin{eqnarray} &=& \frac{S}{\sigma _{\rm chan}\Delta \nu _{\rm chan} \sqrt{N_{\rm chan}}} , \end{eqnarray}$$

where the width of the profile is specified as either a frequency units (Δν) or the number of channels (N chan). It is worth noting in the above equations that the product $\sigma _{\rm chan}\sqrt{\Delta _{\nu _{\rm chan}}}$ is independent of the particular choice of channel width used, and as such S/N int is independent of channel choice. To predict the S/N for a point source of known mass and rest frame velocity width, the above can also be alternatively expressed:

(156) $$\begin{eqnarray} S/N_{\rm int} &=& \frac{S}{\sigma _{S_{\nu _{\rm chan}}}}\sqrt{\frac{c(1+z)}{\nu _{\textnormal {{H{\sc \,i}}}} \Delta \nu _{\rm chan} \Delta V_{\rm rest}}} , \end{eqnarray}$$

which substituting for S using Equation (48) gives

(157) $$\begin{eqnarray} S/N_{\rm int} &=& 2.92\times 10^{-4} (1+z)^{\frac{1}{2}} \left( \frac{D_\text{L}}{\rm Mpc} \right)^{-2} \nonumber \\ &&\times \left( \frac{M_{\textnormal {{H{\sc \,i}}}}}{\text{M}_{\odot }} \right) \left( \frac{\Delta V_{\rm rest}}{\rm km\,s^{-1}} \right)^{-\frac{1}{2}} \left( \frac{\Delta \nu _{\rm chan}}{\rm Hz} \right)^{-\frac{1}{2}} \left( \frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy} \right)^{-1}.\nonumber \\ \end{eqnarray}$$

If the source is extended, a further correction of $S/N_{\rm int} \propto 1/\sqrt{(1 + A_{\rm galaxy}/A_{\rm beam}}$ is required to allow for the fact that source flux is distributed over multiple beams, increasing the observed noise (Duffy et al. Reference Duffy2012). Note that this correction factor only disappears if the source is a true point source, rather than just being smaller than the (synthesised) beam. The estimation of signal-to-noise using this correction factor also assumes the optimal extraction of the source signal in both spatial and frequency coordinates, which for low signal-to-noise sources may not be possible.

For an extended source, a generally more appropriate calculation is to determine the expected signal-to-noise from the desired column density sensitivity. For instance, considering the case of single pointing with beam Ωbm at redshift z, the signal-to-noise in the centre of the primary beam will be given by (using Equation (143))

(158) $$\begin{eqnarray} S/N_{N_{\textnormal {{H{\sc \,i}}}}} &=& \frac{N_{\textnormal {{H{\sc \,i}}}_{\rm desired}}}{\sigma _{N_{\textnormal {{H{\sc \,i}}}}}^{\Delta V_{\rm rest}}} , \nonumber \\ &\simeq& 5.50 \times 10^{-23} \, (1+z)^{\frac{2}{7}} \left(\frac{N_{\textnormal {{H{\sc \,i}}}_{\rm desired}}}{\rm cm^{-2}}\right)\nonumber \\ &&\times \left(\frac{\Omega _{\rm bm}}{\rm arcsec^{2}}\right) \left(\frac{\Delta V_{\rm rest}}{\rm km\, s^{-1}}\right)^{-\frac{1}{2}} \left(\frac{\Delta \nu _{\rm chan}}{\rm Hz}\right)^{-\frac{1}{2}} \left( \frac{\sigma _{S_{\nu _{\rm chan}}}}{\rm Jy} \right)^{-1} . \nonumber \\ \end{eqnarray}$$

20 H i FIDELITY CALCULATOR

As a complementary online tool, the H i Fidelity (HiFi) calculator makes available many of the central formulae identified in this paper for ready application to the analysis of, or planning for, H i observations (http://hifi.icrar.org). These include the conversion of observed frame quantities to rest frame equivalents and vice versa, including frequency width and velocity width, flux and mass, flux density and brightness temperature, and flux and column density. Also included are calculators for the estimation of observed noise and signal-to-noise, combining observed frame measurement characteristics with rest frame source properties.

The calculator makes use of the Celestial R packageFootnote 3 for the calculation of cosmological distances. In addition to the non-evolving vacuum energy density calculation outlined in Section 4, this package, and the HiFi calculator, also allow for an evolving vacuum energy model through the use of the w and w′ parameters, replacing ΩΛ in Equation (5) with

(159) $$\begin{equation} \Omega _{\Lambda } \rightarrow \Omega _{\Lambda }\left( \frac{1}{1+z} \right) ^{-(3+3w_{0}+6w^{\prime })} e^{ -6w^{\prime } \left( 1 - \frac{1}{1+z} \right) } , \end{equation}$$

where w 0 = −1 and w′ = 0 return the default non-evolving vacuum energy density.

ACKNOWLEDGEMENTS

We thank Tom Oosterloo, Robert Braun, and Cullan Howlett for very useful conversations contributing to this work, and also extend our thanks to Martin Zwaan for his much appreciated efforts in refereeing this paper. Parts of this research were conducted by the Australian Research Council Centre of Excellence for All-sky Astrophysics (CAASTRO), through project number CE110001020.

APPENDIX A: LITTE H CONVERSIONS

If you need to determine the value of some quantity for a different Hubble constant, and the h C dependencies are given, this can be done by simply calculating the value of h C for your new Hubble constant and then evaluating the expression given for the quantity. For example, to calculate the value of an H i mass given as $M_{\textnormal {{H{\sc \,i}}}} = 10^{9.7} h_{73}^{-2} \text{M}_{\odot }$ for a Hubble constant of H 0 = 100:

(A1) $$\begin{eqnarray} h_{73} &=& \frac{H_{\rm 0}}{73\,\, \mathrm{km\, s^{-1} Mpc^{-1}}} , \hphantom{000} \end{eqnarray}$$
(A2) $$\begin{eqnarray} &=& \frac{100\,\, \mathrm{km\, s^{-1} Mpc^{-1}}}{73\,\, \mathrm{km\, s^{-1} Mpc^{-1}}} , \end{eqnarray}$$
(A3) $$\begin{eqnarray} &=& 1.37, \hphantom{00000000000} \end{eqnarray}$$

then

(A4) $$\begin{eqnarray} M_{\textnormal {{H{\sc \,i}}}} &=& 10^{9.7} h_{73}^{-2} \text{M}_{\odot } , \hphantom{000000000} \end{eqnarray}$$
(A5) $$\begin{eqnarray} &=& 10^{9.7} 1.37^{-2} h_{100}^{-2} \text{M}_{\odot } , \end{eqnarray}$$
(A6) $$\begin{eqnarray} &=& 10^{9.4} h_{100}^{-2} \text{M}_{\odot } . \hphantom{000000} \end{eqnarray}$$

Alternatively running this in reverse, and this time using the abbreviation h = h 100:

(A7) $$\begin{eqnarray} M_{\textnormal {{H{\sc \,i}}}} &=& 10^{9.4} h^{-2} \text{M}_{\odot } ,\hphantom{00000000.} \end{eqnarray}$$
(A8) $$\begin{eqnarray} &=& 10^{9.4} {0.73}^{-2} h_{73}^{-2} \text{M}_{\odot } , \end{eqnarray}$$
(A9) $$\begin{eqnarray} &=& 10^{9.7} h_{73}^{-2} \text{M}_{\odot } . \hphantom{00000.} \end{eqnarray}$$

A final point to note is that the little h dependencies for a quantity can be different, depending on how it was determined. A classic example being the differences that often arise in little h exponents between observed and simulated quantities. The important thing to do if you are wanting to compare two such quantities is to just make sure both values are valid for the same Hubble constant, rather than worrying about the exponents of h C, which are inherently different.

APPENDIX B: SYMBOLS, UNITS, CONSTANTS, AND GLOSSARY

Units:

(B1) $$\begin{eqnarray} 1 \,\rm {Jy} &=& 1^{-26} \,\rm {W} \,\rm {m}^{-2} \,\rm {Hz}^{-1},\hphantom{.} \end{eqnarray}$$
(B2) $$\begin{eqnarray} \text{M}_{\odot } &=& 1.98855 \times 10^{30} {\, \rm kg.} \end{eqnarray}$$

H i constants used in this work:

(B3) $$\begin{eqnarray} \nu _{\textnormal {{H{\sc \,i}}}} &=& 1.420405751786\times 10^{9} \, \rm {\,Hz}, \end{eqnarray}$$
(B4) $$\begin{eqnarray} A_{\textnormal {{H{\sc \,i}}}} &=& 2.86888\times 10^{-15} {\,\rm s^{-1}},\hphantom{00000} \end{eqnarray}$$
(B5) $$\begin{eqnarray} m_{\rm H} &=& 1.673533 \times 10^{-27} {\,\rm kg}. \hphantom{0000.} \end{eqnarray}$$

Glossary of quantities used in this paper and their units:

$$\begin{eqnarray*} \nu &=& \mbox{frequency} \nonumber \\ &&\mbox{(Hz)},\nonumber \\ V &=& \mbox{velocity} \nonumber \\ &&\mbox{(km$\,$s$^{-1}$)},\nonumber \\ S_{\nu } &=& S_{\nu _{\rm obs}} = \mbox{received flux density} \nonumber \\ && \mbox{(10$^{-26}$ W m$^{-2}$ Hz$^{-1}$ = Jy)}, \nonumber \\ \end{eqnarray*}$$\vadjust{\vfill\pagebreak} $$\begin{eqnarray*} S &=& S_{\rm obs} \nonumber = \mbox{received flux} \nonumber \\ &&\mbox{(10$^{-26}$ W m$^{-2}$ = Jy Hz)}, \nonumber \\ S^{V} &=& S^{V}_{\rm obs} = \mbox{received velocity integrated flux} \nonumber \\ && \mbox{(10$^{-26}$ W m$^{-2}$ Hz$^{-1}$ km s$^{-1}$ = Jy km s$^{-1}$)}, \nonumber \\ L_{\nu } &=& L_{\nu _{\rm rest}} = \mbox{emitted luminosity density} \nonumber \\ &&\mbox{(W Hz$^{-1}$)},\nonumber \\ L &=& L_{\rm rest} = \mbox{emitted luminosity} \nonumber \\ && \mbox{(W)}, \nonumber \\ I_{\nu } &=& I_{\nu _{\rm obs}} = \mbox{received specific intensity density} \nonumber \\ && \mbox{(W m$^{-2}$ sr$^{-1}$ Hz$^{-1}$)}, \nonumber \\ I &=& I_{\rm obs} = \mbox{received specific intensity} \nonumber \\ && \mbox{(W m$^{-2}$ sr$^{-1}$)}, \nonumber \\ B_{\nu } &=& B_{\nu _{\rm rest}} = \mbox{emitted surface brightness density} \nonumber \\ && \mbox{ (W m$^{-2}$ sr$^{-1}$ Hz$^{-1}$)}, \nonumber \\ B &=& B_{\rm rest} = \mbox{emitted surface brightness} \nonumber \\ && \mbox{(W m$^{-2}$ sr$^{-1}$)}, \nonumber \\ \mathscr {N}_{\textnormal {{H{\sc \,i}}}} &=& \mbox{number of H\,\textsc {i} atoms}, \nonumber \\ N_{\textnormal {{H{\sc \,i}}}} &=& \mbox{column density of H\,\textsc {i} atoms (cm$^{-2}$)}, \nonumber \\ n_{\textnormal {{H{\sc \,i}}}} &=& \mbox{volume density of H\,\textsc {i} atoms (cm$^{-3}$).} \nonumber \end{eqnarray*}$$

References

REFERENCES

Abdalla, F. B., & Rawlings, S. 2005, 10.1111/j.1365-2966.2005.08650.x MNRAS, 360, 27 2005MNRAS.360. . .27A CrossRefGoogle Scholar
Baldry, I. K., et al. 2012, MNRAS, 421, 621 2012MNRAS.421..621B Google Scholar
Blyth, S., et al. 2015, Advancing Astrophysics with the Square Kilometre Array (AASKA14), 2015aska.confE.128B 128 CrossRefGoogle Scholar
Brinks, E. 1990, in Astrophysics and Space Science Library, Vol. 161, The Interstellar Medium in Galaxies, eds. Thronson, H. A. Jr., & Shull, J. M. (Dordrecht: Kluwer Academic Publishers), 39 1990ASSL..161. . .39B Google Scholar
Croton, D. J. 2013, 10.1017/pasa.2013.31 PASA, 30, 52 2013PASA. . .30. . .52C CrossRefGoogle Scholar
Davis, T. M., & Lineweaver, C. H. 2001, in AIP Conf. Ser., Vol. 555, Cosmology and Particle Physics, eds. Durrer, R., Garcia-Bellido, J., & Shaposhnikov, M. (Melville: AIP Publishing), 348 2001AIPC..555..348D Google Scholar
Davis, T. M., Lineweaver, C. H., & Webb, J. K. 2003, AmJPh, 71, 358 2003AmJPh..71..358D Google Scholar
Davis, T. M., & Scrimgeour, M. I. 2014, 10.1093/mnras/stu920 MNRAS, 442, 1117 2014MNRAS.442.1117D CrossRefGoogle Scholar
Duffy, A. R., et al. 2012, 10.1111/j.1365-2966.2012.21987.x MNRAS, 426, 3385 2012MNRAS.426.3385D CrossRefGoogle Scholar
Einstein, A. 1905, AnP, 322, 891 1905AnP. . .322..891E Google Scholar
Giovanelli, R., & Haynes, M. P. 1988, in Extragalactic Neutral Hydrogen, eds. Verschuur, G. L. & Kellermann, K. I. (2nd edn.; Berlin and New York: Springer-Verlag), 522 1988gera.book..522G Google Scholar
Giovanelli, R., & Haynes, M. P. 2016, 10.1007/s00159-015-0085-3 A&ARv, 2016A 24, 1 CrossRefGoogle Scholar
Hogg, D. W. 1999, arXiv:9905116Google Scholar
Holwerda, B. W., Blyth, S.-L., & Baker, A. J. 2012, in IAU Symp., Vol. 284, The Spectral Energy Distribution of Galaxies – SED 2011, eds. Tuffs, R. J. & Popescu, C. C. (Paris: IAU), 496 2012IAUS..284..496H CrossRefGoogle Scholar
Jaffé, Y. L., Poggianti, B. M., Verheijen, M. A. W., Deshev, B. Z., & van Gorkom, J. H. 2013, 10.1093/mnras/stt250 MNRAS, 431, 2111 2013MNRAS.431.2111J CrossRefGoogle Scholar
Kim, H.-S., Wyithe, J. S. B., Baugh, C. M., Lagos, C. d. P., Power, C., & Park, J. 2017, MNRAS, 465, 111 2017MNRAS.465.111K CrossRefGoogle Scholar
Kim, H.-S., Wyithe, J. S. B., Power, C., Park, J., Lagos, C. d. P., & Baugh, C. M. 2015, 10.1093/mnras/stv1822 MNRAS, 453, 2315 2015MNRAS.453.2315K Google Scholar
Kraus, J. D. 1986, Radio Astronomy (Powell: Cygnus-Quasar)Google Scholar
Martin, A. M., Papastergis, E., Giovanelli, R., Haynes, M. P., Springob, C. M., & Stierwalt, S. 2010, 10.1088/0004-637X/723/2/1359 ApJ, 723, 1359 2010ApJ. . .723.1359M CrossRefGoogle Scholar
Obreschkow, D., Heywood, I., Klöckner, H.-R., & Rawlings, S. 2009, 10.1088/0004-637X/702/2/1321 ApJ, 702, 1321 2009ApJ. . .702.1321O CrossRefGoogle Scholar
Obreschkow, D., Heywood, I., & Rawlings, S. 2011, 10.1088/0004-637X/743/1/84 ApJ, 743, 84 2011ApJ. . .743. . .84O CrossRefGoogle Scholar
Obreschkow, D., Glazebrook, K., Kilborn, V., & Lutz, K. 2016, 10.3847/2041-8205/824/2/L26 ApJL, 824, L26 2016ApJ. . .824L..26O CrossRefGoogle Scholar
Peacock, J. A. 1999, Cosmological Physics (Cambridge: Cambridge University Press)Google Scholar
Schechter, P. 1976, 10.1086/154079 ApJ, 203, 297 1976ApJ. . .203..297S CrossRefGoogle Scholar
Springob, C. M., Haynes, M. P., & Giovanelli, R. 2005, 10.1086/427432 ApJ, 621, 215 2005ApJ. . .621..215S CrossRefGoogle Scholar
Staveley-Smith, L., & Oosterloo, T. 2015, Advancing Astrophysics with the Square Kilometre Array (AASKA14), 2015aska.confE.167S 167 CrossRefGoogle Scholar
Taylor, G. B., Carilli, C. L., & Perley, R. A., eds. 2008, ASP Conf. Ser., Vol. 180, Synthesis Imaging in Radio Astronomy II, A Collection of Lectures from the Sixth NRAO/NMIMT Synthesis Imaging Summer School (4th edn.; San Francisco: ASP)Google Scholar
Weinberg, S. 2008, Cosmology (Oxford: Oxford University Press)Google Scholar
Wilson, T. L., Rohlfs, K., & Hüttemeister, S. 2009, Tools of Radio Astronomy (Berlin: Springer-Verlag)Google Scholar
Zwaan, M. A., Meyer, M. J., Staveley-Smith, L., & Webster, R. L. 2005, 10.1111/j.1745-3933.2005.00029.x MNRAS, 359, L30 2005MNRAS.359L..30Z CrossRefGoogle Scholar
Zwaan, M. A., et al. 2003, 10.1086/374944AJ, 2003AJ. . ..125.2842Z 125, 2842 Google Scholar