The global burden of disease is high from single and multiple micronutrient deficiencies that are estimated to affect over two billion people and at least half of all children aged 6 months to 5 years(1). Micronutrient deficiencies impact growth and key developmental outcomes in early life, and susceptibility and exacerbation of disease and loss in potential across the lifecycle(1). While micronutrient deficiencies are a global health issue leading to detrimental health consequences and long-term impairment, suboptimal, that is subclinical or marginal, micronutrient status has also been associated with adverse health outcomes.
Nutritional status assessment using biochemical indicators, i.e. biomarkers, measured in accessible tissue, e.g. blood or urine, is an important tool for the diagnosis and monitoring of micronutrient status in individual healthcare and population-based surveys. Using reliable and valid biomarkers to determine the nutritional status of a population is crucial for disease prevention strategies(Reference Raghavan, Ashour and Bailey2). To facilitate reliable and early diagnosis of inadequate nutritional status, prior to the development of physiologic symptoms or impaired health, it is critical to have reliable and sensitive biomarkers, convenient, cost-efficient and accessible assays, and validated and internationally harmonised laboratory methods.
In the example of B-vitamins, this narrative review will discuss challenges of existing biomarkers, recent research on the development and testing of new biomarkers, followed by the importance and need for biomarker cut-offs as well as the potential need for age, life stage and ethnic-specific reference intervals. The third part focuses on results of recent interlaboratory comparison studies for harmonisation of existing assays and ongoing international efforts on the development of state-of-the-evidence information material for the selection and interpretation of nutritional biomarkers.
Micronutrient inadequacies: addressing deficiency and suboptimal status
Classical clinical symptoms of micronutrient deficiencies are most known and clinical indicators are well-established for their diagnosis. However, not only chronic micronutrient deficiencies, but also suboptimal micronutrient status, also referred to as marginal or subclinical deficiencies, have been associated with an increased risk of degenerative diseases, as explained herein in the example of B-vitamins.
The B-vitamins folate, vitamin B12, B6 and B2 (i.e. riboflavin) are crucial nutrients for lifelong health given their role in cell formation and a healthy nervous system(Reference Stover3). Folate, vitamin B12, B6 and riboflavin, together with choline, betaine and methionine, are described as methyl nutrients and have inter-related roles in the C1 metabolism(Reference Stover3). The C1 metabolism is critical for basic cellular function and is characterised by the transfer of methyl or other C1 groups in the folate cycle, including for DNA biosynthesis and for DNA and RNA methylation, that are critical epigenetic mechanisms. Vitamin B12 also serves as a coenzyme in the degradation of branched-chain amino acids and odd-chain fatty acids(Reference Allen, Stabler and Savage4). In addition to the C1 metabolism, vitamin B6 and riboflavin also have interdependent roles in the tryptophan-catabolising kynurenine pathway, which forms immunomodulatory metabolites(Reference Ueland, Ulvik and Rios-Avila5). B6, as pyridoxal 5’-phosphate (PLP), is a coenzyme for >160 reactions(Reference Ueland, Ulvik and Rios-Avila5). Riboflavin also functions in iron and energy metabolism(Reference Powers6).
Low levels of folate, vitamin B12 and B6 have been related to the increased risk of chronic diseases such as CVD(Reference Lin, Cheng and Liaw7, Reference de Bree, Verschuren and Blom8), stroke(Reference Kelly, Shih and Kistler9), cognitive impairment(Reference Miller, Green and Mungas10, Reference Hin, Clarke and Sherliker11) and cancer(Reference Lin, Lee and Cook12, Reference Kim13). Suboptimal B6 and B2 are linked with higher colorectal cancer risk(Reference Larsson, Orsini and Wolk14, Reference Eussen, Vollset and Hustad15). Low B6 status is associated with higher risk for breast(Reference Lin, Lee and Cook12) and lung cancer(Reference Johansson, Relton and Ueland16), coronary artery disease(Reference Friso, Jacques and Wilson17, Reference Rimm, Willett and Hu18), stroke(Reference Vanuzzo, Pilotto and Lombardi19) and Alzheimer's disease(Reference Miller, Green and Mungas10). Riboflavin status has also been inversely associated with elevated total homocysteine (tHcy)(Reference Hustad, Ueland and Vollset20) and with blood pressure(Reference Reilly, McNulty and Pentieva21), a major CVD risk factor. Suboptimal folate and B12 status have also been associated with adverse pregnancy outcomes such as neural tube defects(Reference Daly, Kirke and Molloy22, Reference Molloy, Kirke and Troendle23) which reflects the importance of these micronutrients across the lifecycle.
Depending on the nutrient and population, the prevalence of suboptimal micronutrient status may be higher than that of deficiency, as is the case for vitamin B12 status in Canadian adults aged >19 years with 5 % being categorised as B12 deficient and 19 % having suboptimal B12 status(Reference MacFarlane, Greene-Finestone and Shi24). To derive reliable and valid measures of nutrient adequacy, or optimal nutrient status, that is in the absence of clinical signs of deficiency and with optimal nutrient levels allowing for risk reduction of chronic degenerative diseases, sensitive and specific indicators of micronutrient status are needed that respond predictably to changes in micronutrient intake and body stores.
Evaluation of established and new biomarkers
Sensitive biomarkers are critical for the early identification of nutrient inadequacies. Recent research has focused on identifying, characterising and validating early indicators of micronutrient inadequacy.
Biomarkers can be divided into two categories, which are direct and functional indicators. Direct indicators are circulating concentrations of the micronutrient under investigation. In the example of folate, the direct indicators include serum folate and erythrocyte folate concentrations. Serum or plasma folate concentration is a short-term indicator and is impacted by dietary folate intake, postprandial status and genetic modifiers(Reference Stover3). Erythrocyte folate concentration is regarded as a long-term indicator of folate status because erythrocytes incorporate folate only during erythropoiesis, excrete folate during their degeneration and have a half-life of about 60 d(Reference Shane and Bailey25). While serum or plasma folate is sensitive to changes in folate intake, serum total vitamin B12, for example, is considered a direct indicator of low specificity and sensitivity(Reference Yetley, Pfeiffer and Phinney26). An alternative direct indicator for vitamin B12 status is serum holotranscobalamin, the B12 form available to tissues, that was described to be more sensitive to dietary changes compared with total B12 (Reference Greibe and Nexo27, Reference von Castel-Roberts, Morkbak and Nexo28).
In contrast to direct indicators, functional indicators reflect metabolic or functional consequences of an inadequate micronutrient status and are referred to as indicator of intracellular micronutrient deficiency. In the example of vitamin B12 that serves as a coenzyme in the folate-dependent homocysteine remethylation pathway and in the conversion of methylmalonyl-CoA to succinyl-CoA, the two functional indicators of vitamin B12 status are an increased concentration of the substrates of these two vitamin B12-dependent pathways, i.e. elevated plasma tHcy and elevated methylmalonic acid (MMA), a byproduct of methylmalonyl-CoA, respectively(Reference Yetley, Pfeiffer and Phinney26).
Depending on the kinetic of each micronutrient, and thereby how promptly and predictably the direct indicator responds to changes in nutrient intake and body pool size, the diagnosis of nutritional inadequacies may for some micronutrients be best assessed by functional indicators or a combination of both direct and functional indicators. In the case of vitamin B12, the functional indicator plasma MMA is described as the B12 biomarker with the highest sensitivity and specificity compared with other B12 indicators; however, plasma MMA is influenced by kidney function(Reference Rasmussen, Vyberg and Pedersen29) and genetic modifiers(Reference Molloy, Pangilinan and Mills30). Therefore, an expert panel concluded that the assessment of nutritional B12 status should include the measurement of at least one direct, e.g. serum total B12, and one functional indicator, preferably MMA(Reference Yetley, Pfeiffer and Phinney26), to compensate for individual biomarker limitations through the combined use and interpretation of indicators. In the example of riboflavin, the only recognised biomarker for assessing biochemical riboflavin status is the functional indicator erythrocyte glutathione reductase activation coefficient(Reference Madigan, Tracey and McNulty31), given the current lack of a convenient and validated direct indicator. The measurement of erythrocyte glutathione reductase activation coefficient however requires specific and laborious pre-analytical procedures and there is a lack of global accessibility to this assay, resulting in little knowledge about biochemical riboflavin status worldwide.
In light of the findings that suboptimal B6 and B2 status are linked with top causes of morbidity and mortality in industrialised countries, i.e. CVD and cancer, recent research focused on the identification and validation of new and early indicators of functional B6 deficiency. Plasma cystathionine concentration is a sensitive functional indicator of suboptimal B6 status, as shown in healthy young adult men and women after a 28 d dietary B6 restriction(Reference Lamers, Coats and Ralat32, Reference Lamers, Williamson and Ralat33), and seems the most sensitive indicator related to intermediates of the C1 metabolism(Reference Lamers34). The team of Per Ueland(Reference Ueland, Midttun and Windelberg35) developed novel analytical assays for quantitation of B6 and B2 vitamers and biomarkers related to B-vitamin-dependent pathways including the tryptophan–kynurenine pathway that requires both B6 and B2(Reference Midttun, Hustad and Ueland36, Reference Midttun, Hustad and Solheim37). The newly defined biomarkers include the PAr index (i.e. the ratio between the concentration of the B6 degradation product pyridoxic acid, and the sum of the direct indicators PLP and pyridoxal), the 3-hydroxykynurenine:xanthurenic acid ratio and the oxoglutarate:glutamate ratio(Reference Ueland, Ulvik and Rios-Avila5). As for vitamin B12, the combined use of biomarkers is recommended to compensate for the influence of potential confounding variables on each biomarker(Reference Ueland, Ulvik and Rios-Avila5). When validating the new biomarkers, plasma 3-hydroxykynurenine was inversely associated with plasma PLP, the most commonly used direct indicator of B6 status, in a healthy population(Reference Theofylaktopoulou, Ulvik and Midttun38) and in patients with stable angina pectoris(Reference Midttun, Ulvik and Ringdal Pedersen39). Because this association was independent of riboflavin, plasma 3-hydroxykynurenine concentration may serve as a specific, functional indicator of vitamin B6 status(Reference Theofylaktopoulou, Ulvik and Midttun38). Prospective and dose–response intervention studies are needed to validate the new biomarkers and to test the effect of nutritional status on their dynamics.
Derivation of biomarker cut-offs
Nutritional status can be categorised into deficient, suboptimal, adequate and excess status, provided cut-offs are available. Cut-offs are quantitative measures derived to reflect health outcomes and are critical in the validation of nutritional surveys, interventions and population-based screenings and monitoring. The derivation of cut-offs for nutritional biomarkers was comprehensively reviewed by Raghavan et al.(Reference Raghavan, Ashour and Bailey2). In brief, cut-offs can be derived using receiver operating characteristics curves, Youden index or the calculation of reference intervals(Reference Raghavan, Ashour and Bailey2, Reference Ruopp, Perkins and Whitcomb40, Reference Gibson41). Receiver operating characteristics curves have commonly been used to derive cut-offs for nutritional biomarkers and can be used to compare biomarker effectiveness in distinguishing nutritional inadequacy from adequacy(Reference Raghavan, Ashour and Bailey2). Receiver operating characteristics curves allow the calculation of area-under-the-curve values that are a summary measure of the accuracy of the cut-off, with an increasing diagnostic ability of the biomarker with increasing area-under-the-curve values(Reference Raghavan, Ashour and Bailey2). The Youden index is a measure of overall diagnostic effectiveness derived from the receiver operating characteristics curve and used to interpret and evaluate biomarkers(Reference Raghavan, Ashour and Bailey2, Reference Ruopp, Perkins and Whitcomb40). Reference intervals are also commonly used to generate cut-offs(Reference Raghavan, Ashour and Bailey2) and are critical in hospital laboratory settings for derivation of instrument-specific reference ranges of clinical indicators. Reference intervals are derived from reference values, i.e. biomarker concentrations, determined in a reference population, i.e. a sample of the target population. The reference intervals are values in the central 95 % of the distribution and allow the estimation of the upper and lower reference limits, i.e. the upper 97·5 % and lower 2·5 % of biomarker concentrations in the reference population(42).
For many biomarkers, available cut-offs have limited interpretability and have most commonly been derived in adult populations only. In the example of vitamin B12, the combined assessment of at least one direct and one functional indicators is recommended(Reference Yetley, Pfeiffer and Phinney26). There is a lack of consensus on available cut-offs for B12 biomarkers. Limited interpretability of existing cut-offs for serum total B12 and MMA to categorise into deficient, suboptimal and adequate B12 status has been reviewed by Carmel(Reference Carmel43). With data from the US National Adult Health and Nutrition Survey (NHANES 1999–2004), Bailey et al.(Reference Bailey, Carmel and Green44) showed that commonly used cut-offs for serum total B12 and plasma MMA lead to a substantial level of misclassifications, i.e. a large proportion of individuals with normal total B12 concentration had elevated MMA, and 2 % of individuals had normal MMA but low serum total B12 concentration. Current cut-offs need to be validated using defined physiologic and/or clinical endpoints. Until those are established, as Bailey et al. concluded, ‘the public health burden of vitamin B12 deficiency cannot accurately be estimated’(Reference Bailey, Carmel and Green44) in our populations.
Influencing factors on biomarker variability and cut-offs
Current research is addressing the need and derivation of population-specific reference intervals and cut-offs. While micronutrients are critical across the lifespan, physiologic changes related to age, sex or specific life stages, e.g. pregnancy, likely impact the variability of biomarker concentrations and thereby the interpretability of available cut-offs. The age-related variability of biomarker concentrations is reflected in the example of serum folate concentrations measured in the US population as part of the NHANES 2003–2006. Serum folate concentrations were shown to decrease by mid-age and increase again with increasing age, also described as a U-shaped behaviour across the lifespan, that is independent of dietary folate intake(Reference Bailey, Stover and McNulty45).
The paediatric population demonstrates rapid growth and development, including continuous changes in metabolism, making reliable age-specific cut-offs necessary for accurate screening of nutritional inadequacies. To address the lack of paediatric reference ranges, the Canadian Laboratory Initiative for Pediatric Reference Intervals project was created with the goal to establish a database of reference intervals for biochemical indicators in children and to describe the influence of ethnicity, age, sex and BMI on biomarker concentrations(Reference Adeli46). To date, the Canadian Laboratory Initiative for Pediatric Reference Intervals project included the collection of blood samples and data from over 9000 healthy children aged 0–18 years, and reference intervals have been derived for over 100 medical tests and biomarkers, including for serum total vitamin B12(Reference Bailey, Colantonio and Kyriakopoulou47).
Sex-specific differences in biomarker concentrations and kinetics may apply, and sex should be evaluated as potential partition criterion in the derivation of cut-offs. Male–female differences were reported for plasma PLP concentration across the lifespan, in the NHANES 2003–2004(Reference Morris, Picciano and Jacques48). Also circulating concentrations of functional indicators of B6 status, specifically metabolites of the tryptophan–kynurenine pathway, greatly differed between young adult men and women(Reference Deac, Mills and Shane49). The differences in biomarker variability between males and females, those related to biological differences, can be explained by sex-specific or sex-related physiologic differences, e.g. hormonal, and distinct characteristics in body composition, as well as possible sex-linked genetic differences. Sex-specific cut-offs may be less applicable in infants and children, until the age of puberty; sex-specific reference intervals were described for plasma tHcy with higher concentrations in boys compared with girls aged older than 12 years(Reference Bailey, Colantonio and Kyriakopoulou47).
In regard to life stages, there is a lack of pregnancy-specific biomarker cut-offs for vitamin B12 and most other nutrients, which challenges the interpretation of micronutrient status assessment during this critical period of life and key stages of fetal development. Low maternal vitamin B12 status is a risk factor for neural tube defects(Reference Molloy, Kirke and Troendle23), low birth weight(Reference Rogne, Tielemans and Chong50) and reduced cognitive performance in the offspring(Reference Strand, Taneja and Ueland51). With respect to the routinely applied biomarker serum total vitamin B12 and related cut-off, there is a general concern that the rate of B12 deficiency is overestimated during pregnancy because of a natural decrease in serum total B12 concentrations across trimesters of pregnancy(Reference Visentin, Masih and Plumptre52–Reference Koebnick, Heins and Dagnelie54), potentially attributable to pregnancy-related haemodilution, changes in glomerular filtration rate, and the preferential unidirectional transport of nutrients to the developing fetus. Also serum holotranscobalamin, the biomarker reflecting the portion of vitamin B12 available to tissues and alternative direct B12 indicator, significantly decreased between first and second trimester of pregnancy(Reference Schroder, Sinclair and Mattman53), while the functional biomarker plasma MMA increased between the first and second(Reference Schroder, Sinclair and Mattman53), and between second and third trimester(Reference Greibe, Andreasen and Lildballe55). As for cut-offs for all other age and population groups, a defined clinical and/or physiologic endpoint is required to validate cut-offs for the reliable definition of maternal vitamin B12 adequacy and thereby for achieving both maternal health and optimal fetal growth and development.
Consideration of ethnicity as an effect modifier in biomarker concentration and potential risk marker should be carefully evaluated. In our work on maternal micronutrient status in pregnant women of South Asian ethnicity residing in British Columbia, Canada, we showed that women of South Asian ethnicity have substantially lower vitamin B12 status, as shown by the significantly lower serum total B12 and holotranscobalamin concentration and higher serum MMA concentration, compared with women of European ethnicity in early pregnancy(Reference Schroder, Sinclair and Mattman53). There was no significant difference in tHcy concentration between the two ethnic groups; however, this can likely be explained by the high folate status in Canadian pregnant women including our cohort with a median serum folate concentration of about 65 nmol/l(Reference Schroder, Sinclair and Mattman53) and with folate being the main determinant of tHcy concentration(Reference Selhub, Jacques and Rosenberg56). In late pregnancy, i.e. in second or third trimester, pregnant women of South Asian ethnicity had the highest risk of B12 deficiency compared with women of other ethnicities(Reference Jeruszka-Bielak, Isman and Schroder57). Underlying causes may be differences in dietary B12 intake and supplement use related to cultural habits and traditions, potentially higher prevalence of vegetarianism, and/or higher prevalence of genetic variants related to lower serum total B12 concentrations(Reference Tanwar, Chand and Kumar58). However, in a cross-sectional study of young adult women of South Asian and European ethnicity, dietary B12 intake did not differ between ethnic groups despite a trend for lower B12 status in South Asian young adult women(Reference Quay, Schroder and Jeruszka-Bielak59).
Other influencing factors of biomarker concentrations include nutrient–nutrient interactions, drug–nutrient interactions and genetic variants. In the example of B6, oral contraceptive use is associated with lower plasma PLP concentration likely because oestrogen enhances B6-dependent tryptophan catabolism(Reference Morris, Sakakeeny and Jacques60). Inflammatory conditions are associated with low B6 status(Reference Friso, Jacques and Wilson17); and high dietary B6 intake is associated with lower levels of inflammatory markers(Reference Morris, Sakakeeny and Jacques60). Genetic variants of proteins involved in B6 absorption, metabolism and excretion may lead to hypo- or hyper-responsiveness to dietary and/or supplemental intake. The variability of biomarker concentrations in light of these confounding factors requires further investigation in large-scale, population-based studies.
Current international efforts on harmonisation of biomarker measurements
For the comparison of studies from across the globe, the harmonisation of analytical methods is essential and can be realised with the use of internationally available reference material and interlaboratory comparison studies. The requirement for international harmonisation was showcased by the comparison of folate status between the US and Canadian adult population(Reference Colapinto, Tremblay and Aufreiter61). Erythrocyte folate concentration, the long-term indicator of folate status, was measured in the national population-based surveys in the USA and Canada, which are the US NHANES and the Canadian Health Measures Survey, respectively. Assays employed were the microbiological folate assay for the NHANES and an automated immunoassay in the Canadian survey(Reference Colapinto, Tremblay and Aufreiter61). Since implementation of mandatory food fortification with folic acid in North America, the US and Canadian populations are folate replete, and often very high folate concentrations are being reported(Reference Colapinto, O'Connor and Tremblay62), especially in supplement users(Reference Colapinto, O'Connor and Dubois63). Immunoassays have been developed for clinical laboratory settings and the diagnosis of folate deficiency, and have the limitation of a lack of linearity and poor assay performance at high folate concentrations 45,(Reference Lamers64). Despite recommended dilution steps, the assay accuracy decreases with increasing folate concentrations. To account for the different analytical methods used in the two surveys, a conversion equation was developed. With or without the adjustment of folate concentrations employing the conversion factor, the erythrocyte folate concentration in the Canadian survey were higher or lower compared with the US counterparts which led the authors to conclude that ‘caution must be exercised in evaluating erythrocyte folate data from different countries because analytical methods are not readily comparable’(Reference Colapinto, Tremblay and Aufreiter61).
International efforts have been made for the harmonisation of existing assays for several micronutrient biomarkers. Recent interlaboratory comparison studies for folate quantitation assays(Reference Fazili, Sternberg and Paladugula65, Reference Zhang, Sternberg and Pfeiffer66), led by Christine Pfeiffer's team at the US Centers for Disease Control and Prevention, showed good comparability between isotope-dilution liquid chromatography–tandem MS assays for the quantitation of the folate form 5-methyltetrahydrofolate, the main transport form of folate in plasma(Reference Fazili, Sternberg and Paladugula65). However, the results of the different laboratories using either the liquid chromatography–tandem MS method as initially developed by Christine Pfeiffer's team(Reference Pfeiffer, Fazili and McCoy67), or independently developed assays, showed low comparability in the quantitation of folic acid(Reference Fazili, Sternberg and Paladugula65), the fully oxidised folate form commonly found in supplements and fortified foods, that occurs unmetabolised in plasma at intake levels >200 µg of a single dose(Reference Kelly, McPartlin and Goggins68). Individual, national and international efforts should be made to enhance interlaboratory comparison studies and facilitate the harmonisation of biomarker measurements between laboratories. Affordable, accessible and certified reference materials for the various folate forms, and other micronutrient biomarkers, are needed to improve method accuracy(Reference Fazili, Sternberg and Paladugula65) in individual laboratories and globally.
Also, there are ongoing international efforts on the development of state-of-the-evidence information material for the selection and interpretation of nutritional biomarkers. These efforts include the Biomarkers of Nutrition for Development expert panel reviews, of which the review on folate was recently published(Reference Bailey, Stover and McNulty45). A project addressing the interpretability of biomarker concentration, specifically in settings of inflammation and malaria infection, is the Biomarkers Reflecting Inflammation and Nutritional Determinants of Anemia project(Reference Namaste, Aaron and Varadhan69). The outcomes of these efforts will inform guidelines and harmonise strategies in the diagnosis of micronutrient deficiencies.
Conclusions
Micronutrient adequacy is critical for optimal growth and development, and maintenance of health and potential. Establishing sensitive, reliable and cost-efficient biomarkers and related cut-offs for use in populations across the globe are critical to facilitating the early diagnosis of micronutrient inadequacies on the clinical and community-based level for timely intervention and disease prevention. International efforts should be continued, supported and enhanced to facilitate the creation of accessible and harmonised measures to diagnosing and monitoring micronutrient deficiencies. More research is warranted on the identification of nutrient–nutrient interactions, the influence of genetic variants, age, life stage, ethnicity and other potential factors on biomarker variability and related cut-offs. The accessibility to cost-efficient and validated assays should be a global health priority.
Acknowledgements
Y. Lamers thanks the organising committee of the British Nutrition Society Irish Section Meeting for the invitation to contributing to the 2018 Meeting on ‘Targeted Approaches to Tackling Current Nutritional Issues’.
Financial Support
Y. Lamers acknowledges funding from the Canadian Institutes of Health Research/Canada Research Chair Program.
Conflict of Interest
None.