Hostname: page-component-78c5997874-8bhkd Total loading time: 0 Render date: 2024-11-14T05:20:31.219Z Has data issue: false hasContentIssue false

A new methodical approach based on Compton scattering and XRF: quantitative analysis of CO2 and loss on ignition in quicklime

Published online by Cambridge University Press:  20 May 2015

Minoru Inoue*
Affiliation:
Rigaku Corporation, 14-8 Akaoji, Takatsuki, Osaka 569–1146, Japan
Yasujiro Yamada
Affiliation:
Rigaku Corporation, 14-8 Akaoji, Takatsuki, Osaka 569–1146, Japan
Mao Kitamura
Affiliation:
Yabashi Industries Co., LTD, 4278-1 Okubo, Akasaka, Ogaki, Gifu 503–2213, Japan
Norifumi Gotoh
Affiliation:
Yabashi Industries Co., LTD, 4278-1 Okubo, Akasaka, Ogaki, Gifu 503–2213, Japan
Naoki Kawahara
Affiliation:
Rigaku Corporation, 14-8 Akaoji, Takatsuki, Osaka 569–1146, Japan
Michael Mantler
Affiliation:
Rigaku Corporation, 14-8 Akaoji, Takatsuki, Osaka 569–1146, Japan
*
a) Author to whom correspondence should be addressed. Electronic mail: [email protected]

Abstract

The authors present and discuss a method for simultaneous quantitative analysis of total loss on ignition (LOI) (CO2 + H2O) and CO2 content separate from the LOI, in an industrial environment of quicklime production. Total LOI is determined by the Compton scattered Rh tube radiation which is used directly in the calibration equation. The resulting calibration curve for LOI, including matrix correction shows an accuracy of 0.15 mass%. The carbon content (CO2) is distinguished from total LOI by measuring C radiation, which is possible with the required accuracy by employing a new multilayer analyzer with greatly improved background characteristics. The method aims at high reliability and sample throughput and at becoming a less time-consuming alternative to the conventional method of LOI determination by weighing sequences before and after “ignition” at 1050 °C.

Type
Technical Articles
Copyright
Copyright © International Centre for Diffraction Data 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Kataoka, Y., Kawahara, N., Hara, S., Yamada, Y., Matsuo, T., and Mantler, M. (2006). “Fundamental parameter method using scattering X-rays and Monte Carlo simulation”, in European Conf. on X-ray Spectrometry 2006, Paris, France.Google Scholar
Reynolds, R. C. Jr (1963). “Matrix corrections in trace element analysis by X-ray fluorescence: estimation of the mass absorption coefficient by Compton scattering,” Am. Mineral. 48, 11331143.Google Scholar