Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-14T11:14:45.561Z Has data issue: false hasContentIssue false

Bifocal miniature toroidal shaped X-ray mirrors

Published online by Cambridge University Press:  29 February 2012

Sterling Cornaby*
Affiliation:
Cornell High Energy Synchrotron Source (CHESS), Ithaca, New York 14853 School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853
Detlef-M. Smilgies
Affiliation:
School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853
Donald H. Bilderback
Affiliation:
Cornell High Energy Synchrotron Source (CHESS), Ithaca, New York 14853 School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853
*
a)Author to whom correspondence should be addressed. Electronic mail: [email protected]

Abstract

We have fabricated a bifocal miniature toroidal mirror that horizontally and vertically focuses to two different locations to provide a smaller footprint of the beam for grazing-incidence wide-angle scattering (GIWAXS), while at the same time focusing the beam in the horizontal direction on the detector to further enhance the angular resolution. At CHESS we traditionally use glass single-bounce monocapillary optics for a wide range of X-ray experiments to get a fine X-ray beam of 5 to 20 μm. This miniature toroidal mirror was prepared by designing and fabricating an X-ray focusing capillary in which the sagittal and meridional focusing is decoupled and only a quadrant of the accepted annulus is used for focusing the beam. The mirror produced a 120 μm horizontal by 25 μm vertical focus at 50 mm from the tip of the optic and a 44 μm horizontal by 70 μm vertical focus at 150 mm from the tip of the optic.

Type
Technical Articles
Copyright
Copyright © Cambridge University Press 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Als-Nielson, J. and McMorrow, D. (2001). Elements of Modern X-ray Physics (Wiley, New York).Google Scholar
Barrea, R. A., Huang, R., Cornaby, S., Bilderback, D., and Irving, T. (2009). “High-flux, hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam,” J. Synchrotron Radiat. JSYRES 16, 7682.10.1107/S0909049508039782Google Scholar
Bilderback, D. H., Kazimirov, A., Gillilan, R., Cornaby, S., Woll, A., Zha, C. -S., and Hunag, R. (2007). “Optimizing monocapillary optics for synchrotron X-ray diffraction, fluorescence imaging, and spectroscopy applications,” AIP Conf. Proc. APCPCS 879, 758763.10.1063/1.2436172CrossRefGoogle Scholar
Cornaby, S. (2008). “The handbook of X-ray single-bounce monocapillary optics, including optical design and synchrotron applications,” PhD dissertation, Cornell University, New York.Google Scholar
Howell, J. A. and Horowitz, P. (1975). “Ellipsoidal and bent cylindrical condensing mirrors for synchrotron radiation,” Nucl. Instrum. Methods NUIMAL 125, 225230.10.1016/0029-554X(75)90271-2CrossRefGoogle Scholar
Huang, R. (2004). IMAGEPROF (Computer Program), Cornell University, Ithaca, New York 〈http://glasscalc.chess.cornell.edu/ImageProf.shtml〉, Last update 9/2009.Google Scholar
Huang, R. and Bilderback, D. H. (2006). “Single-bounce monocapillaries for focusing synchrotron radiation: Modeling, measurements and theoretical limits,” J. Synchrotron Radiat. JSYRES 13, 7484.10.1107/S0909049505038562Google Scholar
Lamb, J. S., Cornaby, S., Andresen, K., Kwok, L., Park, H. Y., Qiu, X. Y., Smilgies, D. M., Bilderback, D. H., and Pollack, L. (2007). “Focusing capillary optics for use in solution small-angle X-ray scattering,” J. Appl. Crystallogr. JACGAR 40, 193195.10.1107/S0021889806044505CrossRefGoogle Scholar
Limburg, K. E., Huang, R., and Bilderback, D. H. (2007). “Fish otolith trace element maps: New approaches with synchrotron microbeam X-ray fluorescence,” X-Ray Spectrom. XRSPAX 36, 336342.10.1002/xrs.980Google Scholar
Sirenko, A. A., Kazimirov, A., Cornaby, S., Bilderback, D. H., Neuber, B., Bruckner, P., Scholz, F., Shneidman, V., and Ougazzaden, A. (2006). “Microbeam high angular resolution XRD in InGaN/GaN selective-area-grown ridge structures,” Appl. Phys. Lett. APPLAB 89, 181926–181926-3.10.1063/1.2378558CrossRefGoogle Scholar
Woll, A. R., Mass, J., Bisulca, C., Huang, R., Bilderback, D. H., Gruner, S., and Gao, N. (2006). “Development of confocal X-ray fluorescence (XRF) microscopy at the Cornell High Energy Synchrotron Source,” Appl. Phys. A: Mater. Sci. Process. APAMFC 83, 235238.10.1007/s00339-006-3513-4Google Scholar