Hostname: page-component-78c5997874-8bhkd Total loading time: 0 Render date: 2024-11-03T02:50:49.497Z Has data issue: false hasContentIssue false

The Effect of Water Vapor on the Corrosion of Carbon Steel at 65°c

Published online by Cambridge University Press:  15 February 2011

Gregory E. Gdowski
Affiliation:
Lawrence Livermore National Laboratory, Livermore, CA.
John C. Estill
Affiliation:
Lawrence Livermore National Laboratory, Livermore, CA.
Get access

Abstract

AISI 1020 carbon steel was exposed to air at various relative humidities at 65°C. A “critical relative humidity” (CRH) of 75–85% was determined. The CRH is the transitional relative humidity where oxidation/corrosion changes from dry oxidation to aqueous film electrochemical corrosion. Short term testing suggests that aqueous film electrochemical corrosion results in the formation of an inner oxide of Fe3O4, and an outer oxide of a powdery Fe2O3 and/or Fe2O3·xH2O.

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1) Ailor, W.J., ed., Atmospheric Corrosion, John Wiley & Sons, New York, 1982.Google Scholar
2) Duly, S.J., Journal of the Society of Chemical Industry, 69, pp. 304306, 1950.Google Scholar
3) Kaesche, H., Metallic Corrosion, NACE, Houston, pp. 216219, 1985.Google Scholar
4) Greenspan, L., Journal of Research of the National Bureau of Standards, 81A, pp. 8996, 1977.Google Scholar
5) Brown, P.W. and Masters, L.W., Atmospheric Corrosion, Ailor, W.J., ed., John Wiley & Sons, New York, 1982, p. 31.Google Scholar
6) CRC Handbook of Chemistry and Physics. 75th Edition, Lide, D.R., Editor-in-Chief, CRC Press, Boca Raton, FL, 1941, p. 466.Google Scholar