Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-11-24T14:33:16.361Z Has data issue: false hasContentIssue false

X-Ray Study of Strained and Strain Balanced Superlattice Materials

Published online by Cambridge University Press:  25 March 2011

Natee Johnson
Affiliation:
Mechanical Engineering, University of Maryland, Baltimore County, Baltimore, MD, USA.
Ruth Choa
Affiliation:
School of Engineering and Applied Science, Harvard University, Cambridge, MA, USA.
Liwei Cheng
Affiliation:
Computer Science and Electrical Engineering, University of Maryland, Baltimore County, Baltimore, MD, USA.
Fow-Sen Choa
Affiliation:
Computer Science and Electrical Engineering, University of Maryland, Baltimore County, Baltimore, MD, USA.
Get access

Abstract

Nano-scale superlattice (SL) based devices, such as quantum cascade lasers QCLs, have recently become very important due to their capability to identify toxic and explosive chemicals. In manufacturing these Mid-IR photonic devices, atomic-level scanning tunneling microscopes (STM) and transmission electron microscopes (TEM) have been used to characterize the growth quality of superlattice wafers. However, these methods yield observations that are localized and cannot view the entire structure and even now we have not been able to correlate these measured crystal lattice images with device performance. The x-ray scanning technique has greater likelihood of success given that it can observe not only the localized, but also the entire superlattice structure. By extracting special features and key parameters in x-ray diffraction (XRD) patterns, the epitaxial quality of QCL superlattices can be evaluated and correlated to the performance of fabricated QCL devices. We can then differentiate and classify different grades of wafers before starting device fabrication and testing.

Such an example of the usefulness of XRD can be found with strain-balanced superlattices, such as InGaAs/InAlAs, where there is notable decrease in laser performance after relaxation. It can also be found with type-II InAs/GaSb strained layer superlattice, which is currently the best candidate for room temperature mid-IR detectors and focal plane arrays. Experimentally measured x-ray patterns are compared to simulation results and problem sources are identified.

Type
Articles
Copyright
Copyright © Materials Research Society 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Bowen, David Keith, Tanner, Brian Keith, High resolution X-ray diffractometry and topography, CRC Press, 1998.Google Scholar
[2] Paiella, Roberto, Intersubband Transitions in Quantum Structures, McGraw-Hill Companies, January, 2006.Google Scholar