Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-12-01T03:08:34.393Z Has data issue: false hasContentIssue false

Rapid and Sensitive Detection of Nano-fluidically Trapped Protein Biomarkers

Published online by Cambridge University Press:  21 November 2014

Nandhinee Radha Shanmugam
Affiliation:
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, U.S.A.
Anjan Panneer Selvam
Affiliation:
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, U.S.A.
Thomas W. Barrett
Affiliation:
Department of Veterans Affairs, Oregon Health & Science University, Portland, OR, U.S.A.
Steve Kazmierczak
Affiliation:
Department of Pathology, Oregon Health & Science University, Portland, OR, U.S.A.
Shalini Prasad
Affiliation:
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, U.S.A.
Get access

Abstract

In this work, we demonstrate the label-free and ultrasensitive detection of troponin-T, cardiac biomarker using nanoporous membrane integrated on a microelectrode sensor platform. The nanoporous membrane allows for spatial confinement of the protein molecules. Antigen interaction with thiol immobilized antibody perturbs the electrical double layer. Charge perturbations are recorded as impedance change at low frequency using the principle of electrochemical impedance spectroscopy (EIS). The measured impedance change is used to quantitatively determine the concentration of troponin-T in tested sample. We have shown that sensitivity of sensor for troponin-T to be 1pg/mL. The accuracy and reliability of this sensor was tested by comparing the experimental troponin-T concentration values with a commercially available electrochemiluminescence assay measured with Roche Elecsys analyzer. Using this technique we were successful in detecting protein biomarkers in whole blood, human serum, and ionic buffers. This technology provides a robust analytical platform for rapid and sensitive detection of protein biomarkers, thus establishing this technology as an ideal candidate for biomarker screening in clinical settings.

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Ohno, R., et al. ., Electrochemical impedance spectroscopy biosensor with interdigitated electrode for detection of human immunoglobulin A. Biosens Bioelectron, 2013. 40(1): p. 422–6.Google ScholarPubMed
Nagaraj, V.J., et al. ., NanoMonitor: a miniature electronic biosensor for glycan biomarker detection. Nanomedicine (Lond), 2010. 5(3): p. 369–78.Google ScholarPubMed
Arya, S.K. and Bhansali, S., Anti-Prostate Specific Antigen (Anti-PSA) Modified Interdigitated Microelectrode-Based Impedimetric Biosensor for PSA Detection. Biosensors, 2012. 1.Google Scholar
Xu, K., et al. ., Recent Development of Nano-Materials Used in DNA Biosensors. Sensors, 2009. 9: p. 55345557.Google ScholarPubMed
Kumar, R.T.K. and Radha Shanmugam, N., Effect of size matching for ultrasensitive detection of protein biomarkers. Nano LIFE, 2013. 3(4): p. 10.Google Scholar
Ping, G., et al. ., Studies of effects of macromolecular crowding and confinement on protein folding and protein stability. J Mol Recognit, 2004. 17(5): p. 433–40.Google ScholarPubMed
Zaki, A., Dave, N., and Liu, J.W., Amplifying the Macromolecular Crowding Effect Using Nanoparticles. Journal of the American Chemical Society, 2012. 134(1): p. 3538.Google ScholarPubMed
Jianrong, C., et al. ., Nanotechnology and biosensors. Biotechnol Adv, 2004. 22(7): p. 505–18.Google ScholarPubMed
Daniels, J.S. and Pourmand, N., Label-Free Impedance Biosensors: Opportunities and Challenges. Electroanalysis, 2007. 19(12): p. 12391257.Google ScholarPubMed
Grieshaber, D., et al. ., Electrochemical Biosensors - Sensor Principles and Architectures. Sensors, 2008. 8: p. 14001458.Google ScholarPubMed
Ko, S., et al. ., Electrochemical detection of cardiac troponin I using a microchip with the surface-functionalized poly(dimethylsiloxane) channel. Biosens Bioelectron, 2007. 23(1): p. 51–9.Google ScholarPubMed
Qureshi, A., Gurbuz, Y., and Niazi, J.H., Biosensors for cardiac biomarkers detection: A review. Sensors and Actuators B-Chemical, 2012. 171: p. 6276.Google Scholar