Hostname: page-component-cd9895bd7-fscjk Total loading time: 0 Render date: 2024-12-26T20:37:04.337Z Has data issue: false hasContentIssue false

Stereotactic body radiotherapy in Cyberknife® for partial breast irradiation: a review

Published online by Cambridge University Press:  18 January 2021

Carolina De la Pinta*
Affiliation:
Radiation Oncology Department, Ramon y Cajal University Hospital, IRYCIS, Madrid, Spain
Eva Fernández-Lizarbe
Affiliation:
Radiation Oncology Department, Ramon y Cajal University Hospital, IRYCIS, Madrid, Spain
*
Author for correspondence: Carolina De la Pinta, Radiation Oncology Department, Ramon y Cajal University Hospital, IRYCIS, Madrid, Spain. E-mail: [email protected]

Abstract

Introduction:

Partial breast irradiation (PBI) can reduce the volume of treatment and number of treatment sessions in low-risk breast cancer patients. Stereotactic body radiotherapy (SBRT) allows the administration of high doses per fraction thereby reducing the number of fractions and reducing the dose to the surrounding tissues. The objective of this study is to review the literature on the use of SBRT in PBI using the Cyberknife® (CK) unit.

Material and methods:

In this review, we analysed the literature in PubMed and MEDLINE with articles published in the last 10 years. All citations were evaluated for relevant content and validity.

Results:

We include articles in the English language with information about PBI, SBRT in PBI, the use of the CK unit in PBI and other applications of SBRT in breast carcinoma. A total of 68 articles were found and 28 articles were selected for inclusion in this review.

Conclusions:

The treatment of PBI using the CK unit has clear advantages in reducing the treatment volume, and therefore theoretically reducing side effects and good cosmetic results with adequate tumour control. However, the placement of fiducial markers is necessary, requiring an adequate learning curve for the placement of the markers and longer treatment times.

Type
Literature Review
Copyright
© The Author(s), 2021. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Faverly, D, Holland, R, Burgers, L. An original stereomicroscopic analysis of the mammary glandular tree. Virchows Arch A Pathol Anat Histopathol 1992; 421 (2): 115119.CrossRefGoogle ScholarPubMed
Veronesi, U, Cascinelli, N, Mariani, L et al. Twenty-Year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer. N Engl J Med 2002; 347 (16): 12271232.CrossRefGoogle ScholarPubMed
Vicini, F A, Kestin, L L, Goldstein, N S. Defining the clinical target volume for patients with early-stage breast cancer treated with lumpectomy and accelerated partial breast irradiation: a pathologic analysis. Int J Radiat Oncol Biol Phys 2004; 60: 722730.CrossRefGoogle ScholarPubMed
Fisher, E R, Anderson, S, Tan-Chiu, E, Fisher, B, Eaton, L, Wolmark, N. Fifteen-year prognostic discriminants for invasive breast carcinoma. Cancer 2001; 91 (8 suppl): 16791687.3.0.CO;2-8>CrossRefGoogle ScholarPubMed
Dahlberg, K, Mattsson, A, Sandelin, K, Rutqvist, L E. Outcome of treatment for ipsilateral breast tumor recurrence in early-stage breast cancer. Breast Cancer Res Treat 1998; 41 (1): 6978.CrossRefGoogle Scholar
Offersen, B V, Overgaard, M, Kroman, N, Overgaard, J. Accelerated partial breast irradiation as part of breast conserving therapy of early breast carcinoma: a systematic review. Radiother Oncol 2009; 90: 113.CrossRefGoogle ScholarPubMed
Vicini, F, Cecchini, R, White, J et al. Long-Term primary results of accelerated partial breast irradiation after breast-conserving surgery for early-stage breast cancer: a randomised, phase 3, equivalence trial. Lancet 2019; 394 (10215): 21552164.CrossRefGoogle ScholarPubMed
Whelan, T, Julian, J, Levine, M et al. External beam accelerated partial breast irradiation versus whole breast irradiation after breast conserving surgery in women with ductal carcinoma in situ and node-negative breast cancer (RAPID): a randomised controlled trial. Lancet 2019; 394 (10215): 21652172.CrossRefGoogle ScholarPubMed
Livi, L, Meattini, I, Marrazo, L et al. Accelerated partial breast irradiation using intensity-modulated radiotherapy versus whole breast irradiation: 5-year survival analysis of a phase 3 randomised controlled trial. Eur J Cancer 2015; 51: 451463.CrossRefGoogle ScholarPubMed
Smith, B D, Arthur, D W, Buchholz, T A et al. Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO). Int J Radiat Oncol Biol Phys 2009; 74: 9871001.CrossRefGoogle Scholar
Polgár, C, Van Limbergen, E, Pötter, R et al. Patient selection for accelerated partial-breast irradiation (APBI) after breast-conserving surgery: recommendations of the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) breast cancer working group based on clinical evidence. Radiother Oncol 2010; 94: 264273.CrossRefGoogle Scholar
Livi, L, Buonamici, F B, Simontacchi, G et al. Accelerated partial breast irradiation with IMRT: new technical approach and interim analysis of acute toxicity in a phase III randomized clinical trial. Int J Radiat Oncol Biol Phys 2010; 77 (2): 509515.CrossRefGoogle Scholar
Goggin, L M, Descovich, M, McGuinness, C, Shiao, S, Pouliot, J, Park, C. Dosimetric comparison between 3-dimensional conformal and robotic SBRT treatment plans for accelerated partial breast radiotherapy. Technol Cancer Res Treatment 2016; 15 (3): 437445.CrossRefGoogle ScholarPubMed
Heinzerling, J H, Ding, C, Ramirez, E et al. Comparative dose- volume analysis for CyberKnife and 3D conformal partial breast irradiation treatment of early stage breast cancer. Int J Radiat Oncol Biol Phys 2010; 78 (3): S825S826.CrossRefGoogle Scholar
Fan, J, Hayes, S, Freedman, G et al. Planning the breast boost: dosimetric comparison of CyberKnife, photon mini tangents, IMRT, and electron techniques. Int J Radiat Oncol Biol Phys 2010; 78 (3): S788S789.CrossRefGoogle Scholar
Xu, Q, Chen, Y, Grimm, J et al. Dosimetric investigation of accelerated partial breast irradiation (APBI) using CyberKnife. Med Phys 2012; 39 (11): 66216628.CrossRefGoogle ScholarPubMed
Hepel, J T, Tokita, M, MacAusland, S G et al. Toxicity of three- dimensional conformal radiotherapy for accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys 2009; 75: 12901296.CrossRefGoogle ScholarPubMed
Shah, C, Wilkinson, JB, Lanni, T et al. Five-Year outcomes and toxicities using 3-dimensional conformal external beam radiation therapy to deliver accelerated partial breast irradiation. Clin Breast Cancer 2013; 13: 206211.CrossRefGoogle ScholarPubMed
Keisch, M, Vicini, F, Kuske, R et al. Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy. Int J Radiat Oncol Biol Phys 2003; 55: 289293.CrossRefGoogle ScholarPubMed
Yang, T J, Tao, R, Elkhuizen, P H, van Vliet- Vroegindeweij, C, Li, G, Powell, S N. Tumor bed delineation for external beam accelerated partial breast irradiation: a systematic review. Radiother Oncol 2013; 108: 181189.CrossRefGoogle ScholarPubMed
Seiler, S, Rahimi, A, Choudhery, S et al. Ultrasound-Guided placement of gold Fiducial markers for stereotactic partial-breast irradiation. AJR Am J Roentgenol 2016; 207 (3): 685688.CrossRefGoogle ScholarPubMed
Rahimi, A, Thomas, K, Spangler, A et al. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation. Int J Radiation Oncol Biol Phys 2017; 98 (1): 196e205.CrossRefGoogle ScholarPubMed
Obayomi-Davies, O, Kole, T P, Oppong, B et al. Stereotactic accelerated partial breast irradiation for early-stage breast cancer: rationale, feasibility and early experiences using the CyberKnife radiosurgery delivery platform. Front Oncol 2016; 6: 129.CrossRefGoogle Scholar
Vermeulen, S, Cotrutz, C, Morris, A et al. Accelerated partial breast irradiation: using the CyberKnife as the radiation delivery platform in the treatment of early breast cancer. Front Oncol 2011; 1: 43.CrossRefGoogle ScholarPubMed
Mészáros, N, Smanykó, V, Major, T et al. Implementation of Stereotactic Accelerated Partial Breast Irradiation Using CyberKnife –Technical Considerations and Early Experiences of a Phase II Clinical Study. Pathol Oncol Res 2020; 10.1007/s12253-020-00821-3.CrossRefGoogle Scholar
Yoo, S, O’Daniel, J, Blitzblau, R, Yin, F, Horton, J K. Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery. J Radiosurg SBRT 2020; (6): 295301.Google ScholarPubMed
Zhen, X, Zhao, B, Wang, Z, Timmerman, R et al. Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation. Radiat Oncol 2017; 12 (1): 151. PMID: 28893302 PMCID: PMC5594509 DOI: 10.1186/s13014-017-0889-6 CrossRefGoogle ScholarPubMed
Iaccarino, G, Pinnaro, P, Landoni, V et al. ingle fraction partial breast irradiation in prone position. J Exp Clin Cancer Res 2007; 26: 543552.Google Scholar
Pinnaro, P, Arcangeli, S, Giordano, C et al. Toxicity and cosmesis outcomes after single fraction partial breast irradiation in early stage breast cancer. Radiat Oncol 2011; 6: 155.CrossRefGoogle ScholarPubMed
Palta, M, Yoo, S, Adamson, J D, Prosnitz, L R, Horton, J K. Preoperative single fraction partial breast radiotherapy for early- stage breast cancer. Int J Radiat Oncol Biol Phys 2012; 82: 3742.CrossRefGoogle ScholarPubMed
Horton, J K, Blitzblau, R C, Yoo, S, et al. Preoperative single-fraction partial breast radiation therapy: a novel phase 1, dose-escalation protocol with radiation response biomarkers. Int J Radiat Oncol Biol Phys 2015; 92: 846855.CrossRefGoogle ScholarPubMed
Blitzblau, R C, Arya, R, Yoo, S et al. A phase 1 trial of preoperative partial breast radiation therapy: patient selection, target delineation, and dose delivery. Pract Radiat Oncol 2015; 5: e513e20.CrossRefGoogle ScholarPubMed
Charaghvandi, R K, van Asselen, B, Philippens, M E P et al. Redefining radiotherapy for early-stage breast cancer with single dose ablative treatment: a study protocol. BMC Cancer 2017; 17: 181.CrossRefGoogle ScholarPubMed
Nichols, E M, Dhople, A A, Mohiuddin, M, Flannery, T, Yu, C, Regine, W F. Comparative analysis of the post-lumpectomy target volume versus the pre-lumpectomy tumor volume for early-stage breast cancer: implications for the future. Int J Radiat Oncol Biol Phys 2010; 77: 197202.CrossRefGoogle ScholarPubMed
Lozza, L, Fariselli, L, Sandri, M et al. Partial breast irradiation with CyberKnife after breast conserving surgery: a pilot study in early breast cancer. Radiat Oncol 2018; 13 (1): 49.CrossRefGoogle ScholarPubMed
Shibamoto, Y, Murai, T, Suzuki, K et al. Definitive Radiotherapy With SBRT or IMRT Boost for Breast Cancer: Excellent Local Control and Cosmetic Outcome. Technol Cancer Res Treat 2018; 17: 17.CrossRefGoogle ScholarPubMed
Guidolin, K, Yaremko, B, Lynn, K et al. Stereotactic image-guided neoadjuvant ablative single-dose radiation, then lumpectomy, for early breast cancer: the SIGNAL prospective single-arm trial of single-dose radiation therapy. Curr Oncol 2019; (26): 3.Google ScholarPubMed
Bondiau, PY, Courdi, A, Bahadoran, P, Chamorey, E, Queille-Roussel, C, Lallement, M, Birtwisle-Peyrottes, I, Chapellier, C, Pacquelet-Cheli, S, Ferrero, JM. Phase 1 clinical trial of stereotactic body radiation therapy concomitant with neoadjuvant chemotherapy for breast cancer. Int J Radiat Oncol Biol Phys 2013; 85 (5): 11931199. doi: 10.1016/j.ijrobp.2012.10.034 CrossRefGoogle ScholarPubMed