An investigation of the effect of gold nanoparticles with different concentrations on increasing absorbed dose: an empirical and simulation study

Published online by Cambridge University Press:  29 November 2018

Masoumeh Hoseinnezhad
Affiliation:
Physics Department, University of Mazandaran, Babolsar, Iran
Mohammad Mahdavi*
Affiliation:
Physics Department, University of Mazandaran, Babolsar, Iran
Seyyed R. M. Mahdavi
Affiliation:
Radiation Biology Research Center and Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran
Mobarake Mahdavizade
Affiliation:
Radiation Biology Research Center and Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran
*
Author for correspondence: Mohammad Mahdavi, Physics Department, University of Mazandaran, Babolsar, Iran. Tel: +98-35302491. E-mail: [email protected]

Abstract

Purpose

The purpose of this study was to determine the dose enhancement factor (DEF) of gold nanoparticles in a dosimeter gel and construct percentage depth dose curves, using the Optical CT system and the Monte Carlo simulation model, to determine the effect of increasing the dose caused by increasing the concentration of gold nanoparticles at depths in the gel.

Materials and methods

The Magic-f Gel was made based on the relevant protocol in the physics lab. To determine the amount of the increase in the absorbed dose, the gold nanoparticles were added to the gel and irradiated. An increase in the dose after adding nanoparticles to the gel vials was estimated both with the Optical CT system and by the Monte Carlo simulation method.

Results

Dose enhancement curves for doses of 2, 4 and 6 Gy were prepared for gel vials without adding nanoparticles, and nanoparticle gels at concentrations 0·17, 3 and 6 mM. Also, the DEF was estimated. For the 0·17 mM molar gel, the DEF for 2, 4 and 6 Gy was 0·7, 0·743 and 0·801, respectively. For the 3 mM gel, it was 1·98, 2·5 and 2·2, and for the 6 mM gel, it was 37·4, 4·24 and 4·71, respectively.

Conclusion

The enhancement of the dose after adding gold nanoparticles was confirmed both by experimental data and by simulation data.

Type
Original Article
Copyright
© Cambridge University Press 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Cite this article: Hoseinnezhad M, Mahdavi M, Mahdavi SRM, Mahdavizade M. (2019) An investigation of the effect of gold nanoparticles with different concentrations on increasing absorbed dose: an empirical and simulation study. Journal of Radiotherapy in Practice18: 191–197. doi: 10.1017/S1460396918000638

References

1. Khoshgard, K, Hashemi, B, Arbabi, A, Rasaee, MJ, Soleimani, M. Radiosensitization effect of PEGylated gold nanoparticles in orthovoltage X-ray irradiation of the MCF-7 cancerous cell line. Pathobiol Res 2012; 15 (3): 1122.Google Scholar
2. Kakade, NR, Sharma, SD. Dose enhancement in gold nanoparticle-aided radiotherapy for the therapeutic photon beams using Monte Carlo technique. J Canc Res Therapeut 2015; 11 (1): 94.Google Scholar
3. Podgorsak, EB. Review of Radiation Oncology Physics: A Handbook for Teachers and Students. Vienna, Austria: IAE Agency, 2003.Google Scholar
4. Roeske, JC, Nuñez, L, Hoggarth, M, Labay, E, Weichselbaum, RR. Characterization of the theorectical radiation dose enhancement from nanoparticles. Technol Canc Res Treatment 2007; 6 (5): 395401.Google Scholar
5. Zhang, SX, Gao, J, Buchholz, TA et al. Quantifying tumor-selective radiation dose enhancements using gold nanoparticles: a monte carlo simulation study. Biomed Microdevices 2009; 11 (4): 925933.Google Scholar
6. Alkhatib, A, Watanabe, Y, Broadhurst, JH. The local enhancement of radiation dose from photons of MeV energies obtained by introducing materials of high atomic number into the treatment region. Med Phys 2009; 36 (8): 35433548.Google Scholar
7. Marques, T, Schwarcke, M, Garrido, CE, Baffa, O, Nicolucci, P. Dosimetric properties of MAGIC-f polymer gel assessed to radiotherapy clinical beams. In Journal of Physics: Conference Series 2010 (Vol. 250, No. 1, p. 012012). IOP Publishing.Google Scholar
8. Solberg, TD, Norman, A, Iwamoto, KS. Calculation of radiation dose enhancement factors for dose enhancement therapy of brain tumours. Phys Med Biol 1992; 37 (2): 439443.Google Scholar
9. Cho, SH. Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study. Phys Med Biol 2005; 50 (15): N163.Google Scholar
10. Mahdavi, M, Khadem-Abolfazli, M, Mahdavi, SR, Ataei, G. Effect of gold nanoparticle on percentage depth dose of 18 MV X-ray in MAGICA polymer gel dosimeter. J Biomed Phys Eng 2013; 3 (2): 3744.Google Scholar
11. Uusi–Simola, J, Heikkinen, S, Kotiluoto, P et al. MAGIC polymer gel for dosimetric verification in boron neutron capture therapy. J Appl Clin Med Phys 2007; 8 (2): 114123.Google Scholar
12. Stewart, CA. An investigation into the tailoring of bismuth oxide nanoceramic with a biomedical application as a high Z radiation enhancer for cancer therapy. University of Wollongong Australia. 2014: 94.Google Scholar
13. Mesbahi, A, Allahverdi, M, Gheraati, H. Monte carlo dose calculations in conventional thorax fields for 60Co photons. Radiat Med 2005; 23 (5): 341350.Google Scholar
14. Esteve, F, Corde, S, Elleaume, H et al. Enhanced radio sensitivity with iodinated contrast agents using monochromatic synchrotron X-rays on human cancerous cells. Acad Radiol 2002; 9 (2): S540S543.Google Scholar
15. Corde, S, Joubert, A, Adam, JF et al. Synchrotron radiation-based experimental determination of the optimal energy for cell radiotoxicity enhancement following photoelectric effect on stable iodinated compounds. Br J Canc 2004; 91 (3): 544551.Google Scholar
16. Mousavie Anijdan, SH, Shirazi, A et al. Megavoltage dose enhancement of gold nanoparticles for different geometric setups: Measurements and Monte Carlo simulation. Iran J Radiat Res 2012; 10 (3): 183186.Google Scholar
17. Iwamoto, KS, Cochran, ST, Winter, J, Holburt, E, Higashida, RT, Norman, A. Radiation dose enhancement therapy with iodine in rabbit VX-2 brain tumors. Radiother Oncol 1987; 8 (2): 161170.Google Scholar