Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-30T23:36:22.534Z Has data issue: false hasContentIssue false

Void evolution and its dependence on segment length in Cu interconnects

Published online by Cambridge University Press:  01 November 2004

R. Leon
Affiliation:
Jet Propulsion Laboratory, Pasadena, California 91109
J.A. Colon
Affiliation:
California State University, Northridge, California 91330
K.C. Evans
Affiliation:
Jet Propulsion Laboratory, Pasadena, California 91109
D.T. Vu
Affiliation:
Jet Propulsion Laboratory, Pasadena, California 91109
V. Blaschke
Affiliation:
International SEMATECH, Austin, Texas 78741
B. Bavarian
Affiliation:
California State University, Northridge, California 91330
E.T. Ogawa
Affiliation:
University of Texas, Austin, Texas 78712
P.S. Ho
Affiliation:
University of Texas, Austin, Texas 78712
Get access

Abstract

Void evolution during electromigration was studied by recording void nucleation, growth, and displacements at various intervals during thermal (240 °C) and electrical stress tests (2 × 106 amps/cm2) of Cu interconnects. Structural data was collected for various serially arranged line segment lengths and correlated with resistance and increases in resistance due to electromigration-induced thinning and voiding. These results allowed determination of void growth rates in Cu interconnects. Void nucleation and growth show a clear dependence on segment length. Void formation did not occur at the via/interconnect interface, which improved interconnect reliability by allowing extensive voiding before catastrophic failure.

Type
Rapid Communications
Copyright
Copyright © Materials Research Society 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1Ogawa, E.T., Lee, Ki-Don, Blaschke, V.A. and Ho, P.S.: Electromigration reliability issues in dual-damascene Cu interconnections. IEEE Trans. Reliab. 51, 403 (2002).CrossRefGoogle Scholar
2Lloyd, J.R., Clemens, J. and Snede, R.: Copper metallization reliability. Microelectron. Reliab. 39, 1595 (1999).CrossRefGoogle Scholar
3Glickman, E. and Nathan, M.: On the unusual electromigration behavior of copper interconnects. J. Appl. Phys. 80, 3782 (1996).CrossRefGoogle Scholar
4Hu, C-K., Gignac, L., Malhotra, S.G., Rosenberg, R. and Boettcher, S.: Mechanisms for very long electromigration lifetime in dual-damascene Cu interconnections. Appl. Phys. Lett. 78, 904 (2001).CrossRefGoogle Scholar
5Liniger, E.G., Hu, C-K., Gignac, L.M. and Simon, A.: Effect of liner thickness on electromigration lifetime. J. Appl. Phys. 93, 9576 (2003).CrossRefGoogle Scholar
6Lee, K.L., Hu, C-K. and Tu, K.N.: In-situ scanning electron-microscope comparison studies on electromigration of Cu and Cu(Sn) alloys for advanced chip interconnects. J. Appl. Phys. 78, 4428 (1995).CrossRefGoogle Scholar
7Ogawa, E.T., Bierwag, A.J., Lee, K-D., Matsuhashi, H., Justison, P.R., Ramamurthi, A.N., Ho, P.S., Blaschke, V.A., Griffiths, D., Nelsen, A., Breen, M. and Havemann, R.H.: Direct observation of a critical length effect in dual-damascene Cu/oxide interconnects. Appl. Phys. Lett. 78, 2652 (2001).CrossRefGoogle Scholar
8Lee, K-D., Ogawa, E.T., Matsuhashi, H., Justison, P.R., Ko, K-S., Ho, P.S. and Blaschke, V.A.: Electromigration critical length effect in Cu/oxide dual-damascene interconnects. Appl. Phys. Lett. 79, 3236 (2001).CrossRefGoogle Scholar
9Hu, C-K., Rosenberg, R. and Lee, K.Y.: Electromigration path in Cu thin-film lines. Appl. Phys. Lett. 74, 2945 (1999).CrossRefGoogle Scholar
10Blech, I.A.: Electromigration in thin aluminum films on titanium nitride. J. Appl. Phys. 47, 1203 (1976).CrossRefGoogle Scholar