Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-11-30T15:16:48.807Z Has data issue: false hasContentIssue false

79 Flexible Support Materials Maintain Disc Height and Support the Formation of Hydrated Tissue Engineered Intervertebral Discs in Vivo

Published online by Cambridge University Press:  03 April 2024

Alikhan Fidai
Affiliation:
Cornell University
Byumsu Kim
Affiliation:
Cornell University
Marianne Lintz
Affiliation:
Cornell University
Pravesh Gadjradj
Affiliation:
Weill Cornell
Sertac Kirnaz
Affiliation:
Weill Cornell
Blake Boadi
Affiliation:
Weill Cornell
Ibrahim Hussain
Affiliation:
Weill Cornell
Roger Hartl
Affiliation:
Weill Cornell
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

OBJECTIVES/GOALS: We evaluated the long-term success of tissue engineered intervertebral discs (TE-IVDs) cultured in flexible (FPLA) or stiff (PLA) support materials, hypothesizing that FPLA would maintain disc height and tissue hydration in the minipig spine. METHODS/STUDY POPULATION: TE-IVD: NP cells were encapsulated in alginate and NP plugs were placed in the center of FPLA cages. AF cells were encapsulated in type I collagen and pipetted around NP plugs. Implantation: Empty FPLA cages (n=4), and TE-IVDs cultured in FPLA (n=4) were implanted at C3-4 or C5-6 following complete discectomy (DX) in skeletally mature minipigs (n=4). Imaging and Quantification: Terminal disc height indices (DHI) were calculated from weekly x-rays using a previously described method, and results were compared to the PLA pilot study. T2 MRI scans were taken of levels treated with TE-IVDs to quantify disc hydration as previously described. RESULTS/ANTICIPATED RESULTS: FPLA cages restored DHIs to native levels until endpoint. In contrast, PLA cages fractured, and terminal DHIs were statistically similar to DX levels. Of the four levels treated with TE-IVDs, 2 were displaced from the disc space. Stabilized levels yielded DHIs which were statistically similar to native IVD and greater than displaced and DX levels. Displaced levels yielded DHIs which were significantly lower than native and stabilized levels, but greater than DX levels (P<0.05). T2 MRIs of stabilized TEIVDs revealed that levels treated with a construct maintained tissue hydration which was significantly greater than levels treated with an empty cage or DX levels (P<0.0001), but which was about half the hydration of native disc tissue. DISCUSSION/SIGNIFICANCE: Implanting TE-IVDs with FPLA support cages leads to disc height maintenance and the stabilization of hydrated tissues in the spine, enhancing the long term success of TE-IVD implants and providing a basis for clinical translation.

Type
Contemporary Research Challenges
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - ND
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.
Copyright
© The Author(s), 2024. The Association for Clinical and Translational Science