Introduction
Regular screening and early detection of breast cancer can reduce the mortality rate of the women population worldwide. In [Reference Li, Davis, Hagness, Van der Weide and Van Veen1–Reference Dabbagh, Abdullah, Ramasindarum and Abu Kasim3], investigation related to microwave imaging, magnetic resonance imaging (MRI)-derived three-dimensional printing technology, and thermal therapies have been carried out for early detection of tumor or breast cancer. The microwave imaging technique is inexpensive compared to MRI and low sensitivity ultrasound, and much comfortable than mammography (less sensitivity) is of great use. Tumors can be benign and malignant, as described in [Reference Henriksson, Klemm, Gibbins, Leendertz, Horseman, Preece, Benjamin and Craddock4], which are thoroughly explained here. Novel techniques for the early detection of tumors can increase the quality of life and decrease the number of deaths. Joines et al. [Reference Joines, Jirtle, Rafal and Schaefer5] showed tumors have a high-dielectric constant compared to healthy tissue for different frequency ranges, which becomes the main feature for breast cancer detection using microwave techniques over existing mammography and ultrasound imaging. Klemm et al. [Reference Klemm, Craddock, Leendertz, Preece and Benjamin6] presented a ultrawideband (UWB) microwave system for breast cancer detection with various tumor sizes. Islam et al. [Reference Islam, Samsuzzaman, Rahman and Islam7] proposed different antennas for microwave imaging breast cancer detection. Phantoms are basically artificial models or structure of body organs. Apart from geometrical structures, parameters like permittivity and conductivity are important for preparing phantoms. A different mixing recipe is proposed to balance the dielectric properties of a phantom model. A human breast has a relatively simple kind of structure that is easy to reproduce through simulation. Fluid glycerine [Reference Meaney, Fox, Geimer and Paulsen8], rubber–carbon mixture, and Triton X-100 [Reference Oliveira, OL'oughlin, OH'alloran, Porter, Glavin and Jones9] are the materials used for tissue replacement previously. Joachimowicz et al. [Reference Joachimowicz, Conessa, Henriksson and Duchêne10] designed a heterogeneous phantom and measured characteristics over a 0.5–6 GHz frequency range. Lazebnik et al. [Reference Lazebnik, Okoniewski, Booske and Hagness11] have modeled dielectric properties for normal and malignant tissues from 500 MHz to 20 GHz and 3.1–10.6 GHz using one-pole and two-pole Debye models, respectively. A muscle equivalent model designed using agar [Reference Kato, Hiraoka and Ishida12] is reliable for its high-melting point. Mashal et al. [Reference Mashal, Gao and Hagness13] developed a heterogeneous breast phantom for microwave imaging experiments using the oil–gelatin mixture, but it is very delicate in nature. Lazebnik et al. [Reference Lazebnik, Madsen, Frank and Hagness14] proposed tissue mimicking phantom models for UWB applications from 500 MHz to 20 GHz. Liquid-based phantoms proposed earlier is not suitable for structures which require both interior and exterior shells to form the breast anatomy. Davis et al. [Reference Davis, Van Veen, Hagness and Kelcz15] characterized breast tumor based on UWB backscatter for different sizes of tumor. An artificial intelligence method has been introduced for statistically detecting breast cancers using broadband antennas [Reference Woten and El-Shenawee16]. It has used dual-polarized antennas detecting tumor statistically using artificial neural networks with S-parameter inputs (S 11 and S 21). Salvador et al. [Reference Salvador and Vecchi17] has proposed an algorithm for compensating backscatter propagation and detected tumor on phantom below 1 GHz successfully. Bahrami et al. [Reference Bahramiabarghouei, Porter, Santorelli, Gosselin and Popović18] have designed an array of flexible antennas operating from 2 to 4 GHz for breast cancer detection. Flexible antennas are suitable for on-body application and offer robust performance at different bending radii. Datta et al. [Reference Dutta, Basu and Talukdar19] have applied machine learning algorithm to analyze microwave signals for detecting various lower body movements using flexible antennas. Hazarika et al. [Reference Hazarika, Basu and Nandi20] Parsha et al. [Reference Parsha, Nandi and Basu21] show high-gain artificial magnetic conductor- and electromagnetic band-gap-based antennas for onbody communication purposes.
In this paper, we propose machine learning-based approaches to classify the malignant and healthy breast tissues exploiting the variation of reflection and transmission coefficients of the antennas embedded on a human breast model. Three layers of heterogeneous breast phantom model with and without tumor are prepared, and the dielectric characterization is performed to resemble the live human breast tissue. A schematic of a breast phantom model is shown in Fig. 1. A flexible, biocompatible textile substrate is also characterized and used to fabricate the transmitting and receiving antennas embedded on the artificial phantom model. The S parameters of the antennas are captured and analyzed for different locations and sizes of the tumor within the breast phantom. Support vector machine, a supervised machine learning model, is exploited to classify S 11, S 21, and the combination of S 11 and S 21 for healthy tissues and malignant tumors at different locations with different sizes. The confusion matrix shows that the analysis based on the combination of S 11 and S 21 signals offers the highest accuracy of detection of malignant cells.
Dielectric properties of breast phantom
The breast tissues possess different dielectric properties (relative permittivity and conductivity) at different layers. The proposed phantom model has four constituents: skin, fat, gland, and tumor. The phantom model dielectric properties, which are frequency dependent, can be characterized by the single-pole dispersive Debye equation:
where εr and σs are the frequency-dependent dielectric constant and static conductivity of the tissue, ε0 is the dielectric permittivity of vacuum, ω is the angular frequency, σs/(ωɛ0) is the dielectric losses, ɛ ∞ is the relative permittivity at high frequencies, ɛS is the static relative permittivity, and τ is the relaxation time.
Fabrication of heterogeneous breast phantom
The different layers of preparation of a phantom model is shown in Fig. 2. Three layers of the breast phantom model are prepared by mixing the constituents, as shown in Table 1. At first, the skin is prepared by mixing the constituents as mentioned in Table 1. All the materials are taken accordingly to their specific concentrations and heated in a double boiler for 5–7 min until the temperature rises to 50°C. Then they are thoroughly stirred until the temperature drops to 25°C. The mixture is placed within a bowl of 110 mm diameter and another bowl of 106 mm diameter is then pressed within it so that the skin layer achieves the required thickness of 2.1 mm. Vinegar (0.7 mL) is added as a preservative and the mixture is refrigerated overnight.
The fat is prepared using the same chemicals at different proportions and heated in a double boiler until the temperature rises to 50°C. Then they are stirred until the temperature of the mixture drops to 25°C. The mixture is then emptied into the space within the skin layer. A bowl of required diameter is then pressed on it to achieve the required thickness of 33 mm.
The gland is the penultimate layer which is prepared following similar steps considering the different proportions of mixtures. The prepared solution is then emptied into the space in between the fat layer, as shown in Table 1. Straws of various diameters 5, 10, 15, and 20 mm are inserted into it and kept refrigerated overnight.
The tumor prepared by different mixtures of constituents is finally inserted into the gland using the straws of different diameters, as mentioned in Table 1.
Measurement of the fabricated phantom
The dielectric properties for different components of the phantom model are measured using a Rohde & Schwarz ZXX network analyzer via a DAK probe at 23°C. The measured values match the realistic one as showed in [Reference Islam, Samsuzzaman, Kibria and Islam22]. The detailed experimental setup is shown in Fig. 3(a). The values of the conductivity and permittivity of skin, fat, gland, and tumors for the frequency range of 3–10 GHz are shown in Figs 3(b) and 3(c), respectively. The average values of permittivity and conductivity for different components are presented in Table 2.
Antenna design
The variation of the scattering parameters of the wearable antenna proximity to the human body is investigated in the proposed work. The dispersion of the radio parameters through different layers is exploited to differentiate the malicious and healthy breast tissues. In the study, two identical antennas are designed and placed on the breast phantom model as a transmitter and a receiver, respectively. Due to the transmission of short pulses through the breast region, the transmission and the reflection coefficient vary. The antennas exhibit a broadband behavior, and the deviations of S 21 and S 11 for a wide range of frequencies are recorded for the different tissue models present on the phantom. To design the textile antenna, dielectric properties of the textile substrate are characterized for 3–10 GHz frequencies using R&S ZXX material characterized and presented in Fig. 4(a). In the experiment, a denim substrate of dimensions 30 mm × 30 mm and thickness 0.8 mm is considered. The exact permittivity and conductivity are inserted in the material library of HFSS simulation software, and the UWB textile antennas resonating from 3 to 10 GHz are designed as shown in Fig. 4(b). The dimensions of the proposed antennas are rigorously optimized and obtained as follows: Wp = 15 mm, Lp = 11.2 mm, Lp1 = 1.8 mm, Wp1 = 3.8 mm, S1 = 2 mm, LF = 10 mm, and WF = 3.5 mm. A partial ground plane of dimensions WG = 30 mm and LG = 10 mm and the staircase pattern of the antenna are utilized to obtain the wide bandwidth and compact size. The simulated and measured values of reflection coefficient (S 11) and transmission coefficient (S 21) of both the identical antennas for the frequency range 3–10 GHz are shown in Fig. 4(c). The gain and efficiency of the antenna in air and on the phantom model are shown in Figs 4(d) and 4(e) respectively. It is seen from Figs 4(d) and 4(e) that both the parameters deteriorate when the antenna is experimented placing on the phantom model. The proposed antenna is robust and offers reasonable gain, however which is essential for capturing the deviation of scattering parameters in air as well as phantom at a wide range of frequencies due to dielectric variation.
Results and discussion
Scattering parameter measurement setup
The measurements are made using a two port Anritsu-MS2037C Vector Network Analyzer (VNA). As the maximum output power of the VNA is − 3 dBm, the test antenna is fed with 0.5 mW power. For the S 11 and S 21 measurements, both the antennas are connected to the VNA via port 1 and port 2 and placed on or near the breast phantom model, as shown in Fig. 5. Measurements are recorded for the different positions and sizes of the tumors around the breast phantom.
Multiple data sets of S 11 and S 21 are created for 20 different locations of the antennas on the breast phantom with and without tumor and exploited for the classification of the tumor. In this study, we have used a support vector machine (SVM) classifier, which is a supervised machine learning model. The experiment has exploited a cubic polynomial kernel function on each data instance to map the original nonlinear observations into a higher-dimensional space in which they become separable. The box constraint level of the cubic polynomial kernel function is set at 1 for the current study. For the classification, we have utilized the classification learner toolbox in MATLAB. The workflow of the training is shown in Fig. 6.
The variation of S 11 and S 21 for the five cases: without tumor and with tumor of diameter 10 mm placed at four different locations are depicted in Figs 7(a)–7(e) and 8(a)–8(e), respectively. Owing to the detuning of the resonance frequency as in Fig. 7 the radiation characteristics of the antenna become affected which deteriorate the antenna gain and efficiency significantly as shown in Figs 4(d) and 4(e) respectively. Thus, the measured gain and efficiency subjected to different conditions may also be considered for the investigation. However, in this article we have studied only S 11 and S 21 parameters for the required analysis.
The S parameters are measured for various tumor sizes, having diameters of 5, 10, 15, and 20 mm positioned at a fixed location on the breast phantom model. Twenty sets of S 11 and S 22 data are recorded considering different antenna locations for multi-class classification. The variations of S 11 and S 21 for a specific antenna location for different tumor sizes are shown in Figs 9 and 10, respectively.
The statistical parameters including different features of the S 11 and S 21 data of the tumors at different locations and different sizes are extracted and presented in Table 3 and 4, respectively.
Figures 11 and 12 present the confusion matrix for different tumor locations and sizes of the tumors.
Table 5 presents the precision of the diagnostic for both the cases using the classifier. The data presented in Tables 5 and 6 are calculated from the confusion matrix, considering TP (true positive), FP (false positive), FN (false negative), and TN (true negative) values. It is seen that the higher the value of TP, the better the classifier is.
The 5-fold cross-validation method is used to measure the performance, which means for testing purposes, 20% of data is utilized. It is seen that as the number of features is increased, the accuracy of prediction is also increased.
Figure 13 shows the overall classification accuracy while the tumor is placed at four different locations on the breast phantom. It is seen that an average accuracy of 94% is achieved while using both S 11 and S 21 for classification. In contrast, 84 and 89% accuracy are achieved using S 11 and S 21, respectively. Alongside, Fig. 13 presents the accuracy of the proposed technique for classifying four different sizes of tumors exploiting S 11, S 21, and the combination of S 11 and S 22. It is seen that an average accuracy of 94.5% is achieved while using both S 11 and S 21 for classification. In contrast, 84 and 89% accuracy are achieved using S 11 and S 21, respectively. Along with SVM, few other classifiers like Naïve Bayes, Decision tree, k-nearest neighbors (KNN), and neural network (NN) are used for the classification and statistical performances are listed in Table 6. SVM offers superior performances in every aspect compared to that of the rest.
Specific absorption rate (SAR) analysis for the flexible textile antenna over different parts of the phantom model is performed. The average SAR value (for 1 g or 10 m) is calculated [Reference Rao, Yadav and Mishra23, Reference Subramanian, Sundarambal and Nirmal24] for different phantom parts with an input power of 100 mW. The SAR values for skin, fat, and gland are 0.0251, 0.2098, and 0.2247 W/kg, respectively, as shown in Fig. 14, which falls under the limit set by FCC and IEC standards.
Conclusion
In this paper, a machine learning approach is proposed for the classification of breast tumor based on the reflection and transmission coefficients of the UWB antenna. The breast phantom is fabricated to match the dielectric properties of the realistic tissues. The dielectric properties of the artificial phantom layers, tumors, and the textile substrate are rigorously characterized for the entire frequency ranges from 3 to 10 GHz. The designed antenna is flexible, robust, and offers reasonably good gain over the entire band of operation and thus considered for capturing the variation of S-parameters due to the healthy tissues and malignant cells of different sizes present at a different location within the breast model. SVM provides the highest classification accuracy of 93% as the combination of S 11 and S 21 are considered, but 84 and 89% accuracies as S 11 and S 21 are used separately. The effect of the location and size of the tumor on the classification accuracy is investigated and described in the confusion matrix statistically. For comparative evaluation, other classifiers are used, and SVM is proved to be the most accurate one. The proposed technique is inexpensive, reasonably accurate, and effective for early stage detection and continuous monitoring of breast cancer.
Nirmalya Das received his B.Engg. degree in electronics and communication engineering from the Tripura Institute of Technology, Agartala, Tripura, India, in 2013, his M.Tech. degree in communication engineering from the Kalinga Institute of Industrial Technology, India, in 2015. He is currently pursuing his Ph.D. in electronics and communication engineering from the National Institute of Technology Silchar, Assam, India. His current research interests include wearable antennas, artificial intelligence, digital signal processing, and biomedical engineering.
Banani Basu received her B.Engg. degree in electronics and communication engineering from the Jalpaiguri Government Engineering College, West Bengal, India, in 2004, her M.Tech. degree in communication engineering from the West Bengal University of Technology, India, in 2008, andher Ph.D. degree in antenna array optimization from the National Institute of Technology Durgapur, West Bengal, India, in 2012. She is currently an Assistant Professor in the Department of Electronics and Communication Engineering with the National Institute of Technology Silchar, Assam, India. Her current research interests include direction-of-arrival estimation of signals and antenna array optimization.
Sagar Dutta received his B.Engg. degree in electronics and telecommunication engineering from the Gauhati University, Assam, India, in 2015 and his M.Engg. degree in telecommunication engineering from the Asian Institute of Technology, Pathumthani, Thailand, in 2017. He is currently pursuing his Ph.D. in electronics and communication engineering from the National Institute of Technology Silchar, Assam, India. His current research interests include wearable antennas, deep learning, digital signal processing, and biomedical engineering.
Arnab Nandi received his BTech degree from Kalyani Government Engineering College, India, in 2003, his MTech degree from the University of Burdwan, India in 2005, and his Ph.D. from the National Institute of Technology, Durgapur, India in 2012, all in electronics and communication engineering. Currently, he is an assistant professor in the Department of ECE, NIT Silchar, India. His research interests include ad-hoc wireless networks, wireless sensor networks, cross-layer issues, medium access control, antenna design, and artificial magnetic conductor structures.