Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-25T16:17:44.075Z Has data issue: false hasContentIssue false

Some comments on the design of échelle spectrographs using R2 or R4 gratings for precise radial-velocity measurements

Published online by Cambridge University Press:  12 April 2016

John Hearnshaw
Affiliation:
Dept. of Physics and Astronomy, University of Canterbury, Christchurch, New Zealand
Norman Rumsey
Affiliation:
21 Malone Rd, Lower Hutt, NZ and Carter Observatory, Wellington, New Zealand
Garry Nankivell
Affiliation:
43 Holland St., Wainuiomata, Lower Hutt, NZ and Carter Observatory, Wellington, New Zealand

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

A new fiber-fed échelle spectrograph (Hercules) is being designed for the 1-m telescope at Mt John University Observatory. The goals are to have a wavelength capability of 380 to 880 nm, covered in a single exposure on a 50-mm square CCD, to have a choice of resolving powers of 35000 or 70000 and to have no moving parts. High precision radialvelocity observations are a major but not the only goal. Designs with both R2 (blaze angle 63.4 deg) and R4 (blaze angle 76 deg) échelle gratings are being considered, in either case with a dimension of 408 mm perpendicular to the grooves.

Type
Part 1. Instruments
Copyright
Copyright © Astronomical Society of the Pacific 1999

References

Baranne, A., Queloz, D., Mayor, M., Adrianzyk, G., Knispel, G., Kohler, D., Lacroix, D., Meunier, J.-P., Rimbaud, G. & Vin, A. 1996, A&A Supp. 119, 373.Google Scholar
Epps, H.W. 1998, in Optical astronomical instrumentation, Proc. SPIE Conf. 3355, paper 64.Google Scholar
Libbrecht, K.G. & Peri, M.L. 1995, PASP 107, 62.CrossRefGoogle Scholar
Schroeder, D.J. & Hilliard, R.L. 1980, Appl. Optics 19, 2833.CrossRefGoogle Scholar