Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-12-01T01:44:51.548Z Has data issue: false hasContentIssue false

Pseudobacteremia

Published online by Cambridge University Press:  02 January 2015

Joseph F. John Jr.
Affiliation:
Departments of Medicine and Laboratory Medicine, Medical University of South Carolinaand Veterans Administration Medical Center Charleston, South Carolina
Edward R. Bannister
Affiliation:
Departments of Medicine and Laboratory Medicine, Medical University of South Carolinaand Veterans Administration Medical Center Charleston, South Carolina
Rights & Permissions [Opens in a new window]

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Editorial
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1984

References

1.Weinstein, RA, Stamm, WE, Pseudoepidemics in hospitals. Lamet 1977;2:862864.Google Scholar
2.Maki, DG, Through a glass darkly. Nosocomial pseudoepidemics and pseudobacteremia. Arch Intern Med 1980;140:2628.CrossRefGoogle Scholar
3.Kusek, JW, Nosocomial pseudobacteremia and pseudoinfections: An increasing problem. Am J Infect Control 1981;9:2025.CrossRefGoogle Scholar
4.Hoffman, PC, Arnow, PM, Goldmann, DA, et al: False-positive blood cultures. Association with nonsterile blood collection tubes. JAMA 1976;236:20732075.CrossRefGoogle ScholarPubMed
5.Kaslow, RA, Mackel, DC, Mallison, GF, Nosocomial pseudobacteremia: Positive blood cultures due to contaminated benzalkonium antiseptic. JAMA 1976;236:24072409.CrossRefGoogle ScholarPubMed
6.Noble, RC, Reeves, SA, Bacillus species Pseudosepsis caused by contaminated blood culture media. JAMA 1974;230:10021004.CrossRefGoogle ScholarPubMed
7.Greenwood, GP, Highsmith, AK, Allen, JR, et al: Klebsiella pneumoniae due to radiometric blood culture analyzer. Am J Infect Control 1981;2:460465.CrossRefGoogle Scholar
8.Griffin, MR, Miller, AD, Davis, AC, Blood culture contamination associated with a radiometric analyzer. J Clin Microbiol 1982;15:567570.CrossRefGoogle ScholarPubMed
9.Berger, SA, Pseudobacteremia due to contaminated alcohol swabs. J Clin Microbiol 1983;18:974975.CrossRefGoogle ScholarPubMed
10.Craven, DE, Lichtenberg, DA, Browne, KF, et al: Pseudobacteremia traced to cross contamination by an automated blood culture analyzer. Infect Control 1984;5:7578.CrossRefGoogle ScholarPubMed
11.Gurevich, I, Tafuro, P, Krystofiak, SP, et al: Three clusters of bacillus pseudobacteremia related to radiometric culture analyzer. Infect Control 1984;5:7174.CrossRefGoogle ScholarPubMed
12.Haley, RW, Schaberg, DR, Crossley, KB, et al: Extra charges and prolongation of stay attributable to nosocomial infections: A prospective inter-hospital comparison. Am J Med 1981;70:5158.CrossRefGoogle Scholar
13.MacGregor, RB, Beaty, HN, Evaluation of positive blood cultures: Guidelines for early differentiation of contamination from valid positive cultures. Arch Intern Med 1972;130:8487.CrossRefGoogle ScholarPubMed
14.McGowan, JE, Bacteremia in the hospitalized patient. Arch Intern Med 1977;137:1670.CrossRefGoogle ScholarPubMed
15.Gleckman, R, Hibert, D, Afebrile bacteremia: A phenomenon in geriatric patients. JAMA 1982;248:14781481.CrossRefGoogle ScholarPubMed
16.Pickichero, ME, Todd, JK, Detection of neonatal bacteremia. J Pediatr 1979;94:958960.CrossRefGoogle Scholar
17.Kiehn, TE, Wong, B, Edwards, FF, et al: Routine aerobic terminal subculturing of blood cultures in a cancer hospital. J Clin Microbiol 1983;18:885889.CrossRefGoogle Scholar
18.Edwards, LD, Levin, S, Balagatas, R, Ordering patterns and utilization of bacteriologie culture reports. Arch Intern Med 1973;132:678682.CrossRefGoogle Scholar
19.Reller, LB, Recent and innovative methods for detection of bacteremia and fungemia. Am J Med 1983;75 (suppl IB): 2630.CrossRefGoogle ScholarPubMed