Hostname: page-component-cd9895bd7-gxg78 Total loading time: 0 Render date: 2024-12-26T06:56:10.483Z Has data issue: false hasContentIssue false

Infectious Complications of Cryoablation and Microwave Ablation in Metastatic Solid Tumors

Published online by Cambridge University Press:  06 April 2018

Ashish Bhargava*
Affiliation:
Division of Infectious Diseases, St John Hospital and Medical Center, Grosse Pointe Woods, Michigan
Harsha V. Banavasi
Affiliation:
Division of Infectious Diseases, Department of Internal Medicine, Wayne State University School of Medicine, Karmanos Cancer Center, Detroit, Michigan
Pranatharthi H. Chandrasekar
Affiliation:
Division of Infectious Diseases, Department of Internal Medicine, Wayne State University School of Medicine, Karmanos Cancer Center, Detroit, Michigan
*
Address correspondence to Ashish Bhargava MD, FACP, 19251 Mack Ave, Suite 340, Gross Pointe Woods, MI, 48236 ([email protected]).

Abstract

Cryoablation and microwave ablation are commonly used techniques to reduce tumor burden in unresectable neoplasms. This retrospective study demonstrated low risk for infectious complications (1.4%) following these invasive procedures. Abscess formation was the most common infection around the ablation sites. All infections were successfully treated with imaging-guided drainage and antibiotics.

Infect Control Hosp Epidemiol 2018;39:723–726

Type
Concise Communications
Copyright
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

PREVIOUS PRESENTATION. Preliminary data of this study were presented at the Annual Scientific Meeting of the Infectious Diseases Society (ID Week) on October 2-6, 2013 in San Francisco, CA (abstract 1560).

References

REFERENCES

1. Tatli, S, Acar, M, Tuncali, K, Morrison, PR, Silverman, S. Percutaneous cryoablation techniques and clinical applications. Diagnos Interven Radiol (Ankara, Turkey) 2010;16:9095.Google Scholar
2. Simon, CJ, Dupuy, DE, Mayo-Smith, WW. Microwave ablation: principles and applications. Radiographics 2005;25:S69S83.Google Scholar
3. Aghayev, A, Tatli, S. The use of cryoablation in treating liver tumors. Expert Rev Med Device 2014;11:4152.Google Scholar
4. Sheu, YR, Hong, K. Percutaneous lung tumor ablation. Techn Vasc Intervent Radiol 2013;16:239252.Google Scholar
5. Martin, J, Athreya, S. Meta-analysis of cryoablation versus microwave ablation for small renal masses: is there a difference in outcome? Diagn Interv Radiol 2013;19:501507.Google Scholar
6. Niu, L, Li, J, Zeng, J, et al. Comparison of percutaneous cryoablation with microwave ablation in a porcine liver model. Cryobiology 2014;68:194199.Google Scholar
7. Tuncali, K, Morrison, PR, Winalski, CS, et al. MRI-guided percutaneous cryotherapy for soft-tissue and bone metastases: initial experience. Am J Roentgenol 2007;189:232239.Google Scholar
8. Riley, DK, Babinchak, TJ, Zemel, R, Weaver, ML, Rotheram, EB. Infectious complications of hepatic cryosurgery. Clin Infect Dis 1997;24:10011003.Google Scholar
9. Xu, KC, Niu, LZ, He, WB, Hu, YZ, Zuo, JS. Percutaneous cryosurgery for the treatment of hepatic colorectal metastases. World J Gastroenterol 2008;14:14301436.Google Scholar
10. Doughtie, CA, Edwards, JD, Philips, P, et al. Infectious complications in combined colon resection and ablation of colorectal liver metastases. Am J Surg 2015;210:11851191.Google Scholar