Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-28T00:06:06.317Z Has data issue: false hasContentIssue false

Effects of induction of anaesthesia with sufentanil and positive-pressure ventilation on the intra- to extrathoracic volume distribution

Published online by Cambridge University Press:  16 August 2006

T. von Spiegel
Affiliation:
University of Bonn, Department of Anaesthesiology and Intensive Care Medicine, Bonn, Germany
S. Giannaris
Affiliation:
University of Bonn, Department of Anaesthesiology and Intensive Care Medicine, Bonn, Germany
B. Schorn
Affiliation:
Kreiskrankenhaus, Luedenscheid, University of Bonn, Department of Thoracic and Vascular Surgery, Luedenscheid, Germany
M. Scholz
Affiliation:
University of Bonn, Department of Anaesthesiology and Intensive Care Medicine, Bonn, Germany
G. J. K. Wietasch
Affiliation:
University of Bonn, Department of Anaesthesiology and Intensive Care Medicine, Bonn, Germany
A. Hoeft
Affiliation:
University of Bonn, Department of Anaesthesiology and Intensive Care Medicine, Bonn, Germany
Get access

Abstract

Background and objective: Induction of general anaesthesia in combination with positive-pressure ventilation is often associated with a significant decrease of arterial pressure. A decreased preload may contribute to this phenomenon. The aim was to investigate whether a change in cardiac filling occurs following the induction of general anaesthesia with sufentanil under typical clinical conditions.

Methods: Fifteen patients scheduled for elective coronary bypass grafting were studied immediately before surgery. In addition to standard monitors, a transpulmonary double-indicator dilution technique measured in vivo intrathoracic blood volume, global end-diastolic volume and total circulating blood volume. For induction of anaesthesia 2 μg kg−1 sufentanil was given. Measurements were performed awake and after the induction of anaesthesia, intubation and mechanical ventilation of the lungs.

Results: To maintain arterial pressure during the induction period within −20% of baseline pressure, on average 22 ± 6 mL kg−1 crystalloids and 8 ± 6 mL kg−1 colloids were given. Despite these amounts of fluid, cardiac filling was decreased, whereas circulating blood volume increased significantly. Both central venous pressure and pulmonary capillary wedge pressure increased.

Conclusions: Induction of general anaesthesia with positive-pressure ventilation is regularly associated with a blood volume shift from intra- to extrathoracic compartments. Even in low-dose opioid monoanaesthesia with sufentanil – often regarded as relatively inert in haemodynamic terms – the phenomenon could be demonstrated as the primary cause of the often-observed decrease of arterial pressure. It seems, therefore, rationally justified to restore cardiac filling by generous administration of intravenous fluids, at least in patients with unaffected cardiac pump function. During induction of anaesthesia, central venous pressure and pulmonary capillary wedge pressure do not reliably indicate cardiac filling.

Type
Original Article
Copyright
2002 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)