Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-12-01T01:13:49.608Z Has data issue: false hasContentIssue false

Long-term follow-up of stents implanted to relieve peripheral pulmonary arterial stenosis: hemodynamic findings and results of lung perfusion scanning

Published online by Cambridge University Press:  19 August 2008

Isabella Spadoni*
Affiliation:
Department of Pediatric Cardiology, CNR “G. Pasquinucci” Hospital, Massa, Italy.
Sandra Giusti
Affiliation:
Department of Pediatric Cardiology, CNR “G. Pasquinucci” Hospital, Massa, Italy.
Pietro Bertolaccini
Affiliation:
Department of Nuclear Medicine, General Hospital, Massa, Italy.
Alberto Maneschi
Affiliation:
Department of Nuclear Medicine, General Hospital, Massa, Italy.
Giuliano Kraft
Affiliation:
Department of Pediatric Cardiology, CNR “G. Pasquinucci” Hospital, Massa, Italy.
Mario Carminati
Affiliation:
Department of Pediatric Cardiology, CNR “G. Pasquinucci” Hospital, Massa, Italy.
*
Isabella Spadoni, M.D., Cardiologia Pediatrica, CNR Ospedale “G.Pasquinucci”, Via Aurelia Sud-Loc. Montepepe, 54100 Massa, Italy. Tel: +39 0585493566; Fax: +39 0585 493608; E-mail: [email protected]

Abstract

In recent years, percutaneous placement of stents has been used as an alternative to surgery or balloon angioplasty for the treatment of adults with peripheral pulmonary arterial stenosis. This therapy has also been proposed for children, but questions still remain about its indications in this group of patients. We describe here the results of intravascular placement of stents in a group of 29 patients, with a mean age of 12±7 (range 3–31) years and weighing 35 ±19 (range 11–74) kg. All were affected by postsurgical or congenital isolated pulmonary arterial stenosis, and have now been followed for 38 ±19 (range 6–65) months. The early hemodynamic results have been excellent, with a significant reduction of the pulmonary arterial systolic pressure, the systolic pressure gradient, and the ratio of systolic pressures in the pulmonary and systemic circuits, and with a significant increase of the diameter of the stented vessels in all the patients. Of the 29 patients, 24 have been recatheterized 18 ± 10 months after the procedure, demonstrating the stability of the results, with a low incidence of late restenosis, this seen in only 1 patient (2°). Lung perfusion scanning, performed in 17 patients each year after the follow-up catheterization, has showed that the results are maintained at long-term follow-up (51 ±9 months).

Type
Original Articles
Copyright
Copyright © Cambridge University Press 1999

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Hosking, MCK, Thomaidis, C, Hamilton, R, Burrows, PE, Freedom, RM, Benson, LN. Clinical impact of balloon angioplasty for branch pulmonary arterial stenosis. Am J Cardiol 1992; 69: 14671470.CrossRefGoogle ScholarPubMed
2.Rothman, A, Perry, SB, Keane, JF, Lock, JE. Early results and follow-up of balloon angioplasty for branch pulmonary artery scents. J Am Coll Cardiol 1990; 15: 11091117.Google Scholar
3.Mullins, CE, O'Laughlin, MP, Wesley Vick, G III, Mayer, DC, Myers, TJ, Kearney, DL. Implantation of balloon expandable intravascular grafts by catheterization in pulmonary arteries and systemic veins. Circulation 1988; 77: 188199.Google Scholar
4.Morrow, WR, Smith, VC, VanDellen, FA, Ehler, WJ, Mullins, CE. Placement of balloon-expandable stents in surgically created pulmonary artery stenosis: gross and histologic observations. Circulation 1990; 82 Suppl III:111582 (abstract).Google Scholar
5.Benson, LN, Hamilton, R, Dasmahapatra, H, Rabinowitch, M, Coles, JC, Freedom, RM. Percutaneous implantation of a balloon-expandable endoprosthesis for pulmonary artery stenosis: an experimental study. J Am Coll Cardiol 1991; 18: 13031308.CrossRefGoogle ScholarPubMed
6.Rocchini, AP, Meliones, JN, Beekman, RH. Use of balloon-expandable stents to treat experimental peripheral pulmonary artery and superior vena caval stenosis: preliminary experience. Pediatr Cardiol 1992; 13: 9296.CrossRefGoogle ScholarPubMed
7.O'Laughlin, MP, Perry, SP, Lock, JE, Mullins, CE. Use of endovas-cular stents in congenital heart disease. Circulation 1991; 83: 19231939.CrossRefGoogle ScholarPubMed
8.Hosking, MCK, Benson, LN, Nakanishi, T, Burrows, PE, Williams, WG, Freedom, RM. Intravascular stent prosthesis for right ventricular outflow obstruction. J Am Coll Cardiol 1992; 20: 373380.Google Scholar
9.O'Laughlin, MP, Slack, MC, Grifka, RG, Perry, SB, Lock, JE, Mullins, CE. Implantation and intermediate-term follow-up of stents in congenital heart disease. Circulation 1993; 88: 605614.CrossRefGoogle ScholarPubMed
10.Fogelman, R, Nykanen, D, Smallhorn, JF, McCrindle, BW, Freedom, RM, Benson, LN. Endovascular stents in the pulmonary circulation. Circulation 1995; 92: 881885.CrossRefGoogle ScholarPubMed
11.Frank, F, Grifka, RG, Nihill, MR, Mullins, CE. Repeat dilation of intravascular stents in congenital heart defects. Circulation 1995; 92: 893897.Google Scholar
12.Shaffer, KM, Mullins, CE, Grifka, RG, O'Laughin, MP, McMahon, W, Ing, FF, Nihill, MR. Intravascular stents in Congenital Heart Disease: short and long-term results from a large single-center experience. J Am Coll Cardiol 1998;31:661667.CrossRefGoogle Scholar
13.Rhodes, J, Dave, A, Pulling, MC, Geggel, RL, Marx, GR, Fulton, DR, Hijazi, ZM. Effect of pulmonary artery stenoses on the cardiopulmonary response of exercise following repair of Tetralogy of Fallot. Am J Cardiol 1998; 81: 12171219.CrossRefGoogle ScholarPubMed