Hostname: page-component-78c5997874-lj6df Total loading time: 0 Render date: 2024-11-02T20:55:02.416Z Has data issue: false hasContentIssue false

Hemiazygos vein “steal hypoxic-syndrome” after hemi-Fontan operation: comprehensive four-dimensional flow magnetic resonance visualisation

Published online by Cambridge University Press:  08 March 2012

Israel Valverde*
Affiliation:
Division of Imaging Sciences and Biomedical Engineering, King's College London, The National Institute for Health Research Biomedical Research Centre at Guy's & St Thomas’ NHS Foundation Trust Department of Congenital Heart Diseases, Evelina Children's Hospital, Guy's & St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, United Kingdom
Aarthi Razishankar
Affiliation:
Division of Imaging Sciences and Biomedical Engineering, King's College London, The National Institute for Health Research Biomedical Research Centre at Guy's & St Thomas’ NHS Foundation Trust
Owen Miller
Affiliation:
Division of Imaging Sciences and Biomedical Engineering, King's College London, The National Institute for Health Research Biomedical Research Centre at Guy's & St Thomas’ NHS Foundation Trust Department of Congenital Heart Diseases, Evelina Children's Hospital, Guy's & St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, United Kingdom
Reza Razavi
Affiliation:
Division of Imaging Sciences and Biomedical Engineering, King's College London, The National Institute for Health Research Biomedical Research Centre at Guy's & St Thomas’ NHS Foundation Trust Department of Congenital Heart Diseases, Evelina Children's Hospital, Guy's & St Thomas’ NHS Foundation Trust, Westminster Bridge Road, London, United Kingdom
*
Correspondence to: Dr I. Valverde, MD, Clinical Research Assistant in Paediatric Cardiology, Division of Imaging Sciences and Biomedical Engineering, King's College London, The Rayne Institute, 4th floor, Lambeth Wing, St Thomas Hospital, London SE1 7EH, United Kingdom. Mobile: +44 (0) 7702328911; Tel: +44 (0) 2071888385; Fax: +44 (0) 2071885442; E-mail: [email protected]

Abstract

A 2-year-old boy with hypoplastic left heart syndrome and previous hemi-Fontan palliation surgery was referred for cardiovascular magnetic resonance evaluation because of progressive cyanosis. This case report illustrates the advantages of non-invasive four-dimensional magnetic resonance imaging for comprehensive identification and quantification of venovenous collaterals in patients with palliated hemi-Fontan staged surgery.

Type
Brief Report
Copyright
Copyright © Cambridge University Press 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Heinemann, M, Breuer, J, Steger, V, Steil, E, Sieverding, L, Ziemer, G. Incidence and impact of systemic venous collateral development after Glenn and Fontan procedures. Thorac Cardiovasc Surg 2001; 49: 172178.CrossRefGoogle ScholarPubMed
2. Robicsek, F, Sanger, PW, Taylor, FH, Najib, A. The azygos “steal” syndrome in cava-pulmonary anastomosis. Coll Works Cardio Pulm Dis 1963; 66: 434440.Google Scholar
3. Vance, MS, Cohen, MH. Management of azygos vein “steal” following hemi-Fontan by transcatheter coil embolization. Cathet Cardiovasc Diagn 1996; 39: 403406.3.0.CO;2-D>CrossRefGoogle ScholarPubMed
4. Feltes, TF, Bacha, E, IIIBeekman, RH, et al. . Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association. Circulation 2011; 123: 26072652.CrossRefGoogle ScholarPubMed
5. Hayabuchi, Y, Inoue, M, Kagami, S. Rare venous connection causing severe hypoxia after Fontan operation. Interact Cardiovasc Thorac Surg 2008; 7: 718719.CrossRefGoogle ScholarPubMed
6. Valverde, I, Rachel, C, Kuehne, T, Beerbaum, P. Comprehensive four-dimensional phase-contrast flow assessment in hemi-Fontan circulation: systemic-to-pulmonary collateral flow quantification. Cardiol Young 2011; 21: 116119.CrossRefGoogle ScholarPubMed
7. Nordmeyer, S, Riesenkampff, E, Crelier, G, et al. . Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study. JMRI 2010; 32: 677683.CrossRefGoogle ScholarPubMed