Hostname: page-component-586b7cd67f-dsjbd Total loading time: 0 Render date: 2024-11-28T08:57:58.971Z Has data issue: false hasContentIssue false

A 5-year experience with surgical repair of atrial septal defect employing limited exposure

Published online by Cambridge University Press:  19 August 2008

Junaid H. Khan
Affiliation:
Division of Cardiothoracic Surgery, University of California, San Francisco, CA, USA
Doff B. McElhinney
Affiliation:
Division of Cardiothoracic Surgery, University of California, San Francisco, CA, USA
V. Mohan Reddy
Affiliation:
Division of Cardiothoracic Surgery, University of California, San Francisco, CA, USA
Frank L. Hanley*
Affiliation:
Division of Cardiothoracic Surgery, University of California, San Francisco, CA, USA
*
Frank L. Hanley, MD, UCSF Medical Center, 505 Parnassus Avenue M593, San Francisco CA 94143–0118, USA

Abstract

Background

There has been a trend in recent years towards less invasive therapy for many congenital cardiac malformations. For the past 5 years, we have employed a technique of limited surgical exposure when repairing atrial defects within the oval fossa.

Methods

Over the 5-year period from July 1992 to August 1997, 115 consecutive patients underwent surgical repair of an isolated atrial septal defect in the region of the oval fossa by a single surgeon. The patients had a limited midline skin incision starting at the line of the nipples and extending inferiorly across 2 to 3 intercostal spaces. A partial sternotomy was performed, sparing the manubrium. Standard instruments and cannulation techniques were used for cardiopulmonary bypass and fibrillatory arrest.

Results

There were no deaths and no major complications. The median time to extubation after leaving the operating room was 3 hours (30 minutes to 8 days). Mediastinal drains were removed the morning after surgery. The median stay in the intensive care unit was 7 hours (3 hours to 10 days), and patients were discharged from the hospital a median of 4 days postopera-tively (2 to 23 days).

Conclusions

This approach using limited exposure can be applied safely without any new instruments and without peripheral incisions or sites of vascular access, while providing a comfortable exposure for the surgeon and achieving a cosmetically superior result for the patient.

Type
Original Articles
Copyright
Copyright © Cambridge University Press 1999

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Massetti, M, Babatasi, G, Rossi, A, Neri, E, Bhoyroo, S, Zitouni, S, Maragnes, P, Khayat, A. Operation for atrial septal defect through a right anterolateral thoracotomy: Current outcome. Ann Thorac Surg 1996;62: 11001103.CrossRefGoogle ScholarPubMed
2.Laks, H, Hammond, G. A cosmetically acceptable incision for the median sternotomy. J Thorac Cardiovasc Surg 1980;79: 146149.CrossRefGoogle ScholarPubMed
3.Brutel de la Riviere, A, Brom, G, Brom, A. Horizontal submammary skin incision for median sternotomy. Ann Thorac Surg 1981;32: 101104.CrossRefGoogle ScholarPubMed
4.Rao, P, Sideris, E, Hausdorf, G, Rey, C, Lloyd, T, Beekman, R, Worms, A, Bourlon, F, Onorato, E, Khalilluah, M, Haddad, J. International experience with secundum atrial septal defect occlusion by buttoned device. Am Heart J 1994;128: 10221035.CrossRefGoogle ScholarPubMed
5.Sievert, H, Babic, UU, Ensslen, R, Scherer, D, Spies, H, Wiederspahn, T, Zeplin, H. Transcatheter closure of large atrial septal defects with the Babic system. Cathet Cardiovasc Diagn 1995;36: 232240.CrossRefGoogle ScholarPubMed
6.Agarwal, A, Ghosh, P, Mittal, P. Failure of devices used for closure of atrial septal defects: Mechanisms and management. J Thorac Cardiovasc Surg 1996 112: 2126.CrossRefGoogle ScholarPubMed
7.Khan, JH, McElhinney, DB, Reddy, VM, Hanley, FL. Repair of secundum atrial septal defect: limiting the incision without compromising exposure. Ann Thorac Surg 1998;66: 14331435.CrossRefGoogle ScholarPubMed
8.Calafiore, AM, Angelini, GD, Bergsland, J, Salerno, TA. Minimally invasive coronary artery bypass grafting. Ann Thorac Surg 1996;62: 15451548.CrossRefGoogle ScholarPubMed
9.Schwartz, DS, Ribakove, GH, Grossi, EA, Stevens, JH, Siegel, LC, Goar, FG, Peters, WS, McLoughlin, D, Bauman, FG, Colvin, SB, Galloway, AC. Minimally invasive cardiopulmonary bypass with cardioplegic arrest: A closed chest technique with equivalent myocardial protection. J Thorac Cardiovasc Surg 1996;111: 556566.CrossRefGoogle ScholarPubMed
10.Boonstra, PW, Grandjean, JG, Mariani, MA. Reoperative coronary bypass grafting without cardiopulmonary bypass through a small thoracotomy. Ann Thorac Surg 1997;63: 405407.CrossRefGoogle ScholarPubMed
11.Stevens, J, Burdon, T, Peters, W, Siegel, LC, Pompili, MF, Vierra, MA, Goar, FG, Ribakove, GH, Mitchell, RS, Reitz, BA. Portaccess coronary artery bypass grafting: A proposed surgical method. J Thorac Cardiovasc Surg 1996;111: 567573.CrossRefGoogle ScholarPubMed
12.Barbero-Marcial, M, Tanamati, C, Jatene, MB, Atik, E, Jatene, AD. Transxiphoid approach without median sternotomy for the repair of atrial septal defects. Ann Thorac Surg 1998;65: 771774.CrossRefGoogle ScholarPubMed
13.Burke, RP, Wernovsky, G, van der Velde, M, Hansen, D, Castaneda, AR. Video-assisted thoracoscopic surgery for congenital heart disease. J Thorac Cardiovasc Surg 1995;109: 499508.CrossRefGoogle ScholarPubMed
14.Wu, YC, Chang, CH, Lin, PJ, Chu, JJ, Liu, HP, Yang, MW, Hsieh, HC, Tsai, FC. Minimally invasive cardiac surgery for intracardiac congenital lesions. Eur J Cardiothorac Surg 1998;14: S154159.CrossRefGoogle ScholarPubMed
15.Grinda, JM, Folliguet, TA, Dervanian, P, Mace, L, Legault, B, Neveux, J. Right anterolateral thoracotomy for repair of atrial septal defect. Ann Thorac Surg 1996;62: 175178.CrossRefGoogle ScholarPubMed
16.Komai, H, Naito, Y, Fujiwara, K, et al. Lower mid-line skin incision and minimal sternotomy: A more cosmetic challenge for pediatric cardiac surgery. Cardiol Young 1996;6: 7679.CrossRefGoogle Scholar
17.Cherup, L, Siewers, R, Futrell, J. Breast and pectoral muscle maldevelopment after anterolateral and posterolateral throacotomies in children. Ann Thorac Surg 1986;41: 492497.CrossRefGoogle ScholarPubMed
18.Dickinson, D, Arnold, R, Wilkinson, J. Congenital Heart disease among 160,480 liveborn children in Liverpool 1960 to 1969: Implictionsforsurgicaltreatment. Br Heart J 1981;46: 5562.CrossRefGoogle Scholar
19.Murphy, J, Gersh, B, McGoon, M, Mair, D, Porter, C, Ilstrup, D, McGoon, D, Puga, F, Kirklin, J, Danielson, G. Long-term outcome after surgical repair of isolated atrial septal defects. New Eng J Med 1990;323: 16451650.CrossRefGoogle Scholar
20.Lewis, F, Taufic, M. Closure of atrial septal defects with the aid of hypothermia: Experimental accomplishments and the report of one successful case. Surgery 1953;33: 5259.Google ScholarPubMed
21.Gross, R, Watkins, EJ, Pomerane, A, Goldsmith, E. Method for surgical closure of interauricular septal defects. Surg Gynecol Obstet 1953;96: 123.Google ScholarPubMed
22.Boutin, C, Musewe, NN, Smallhorn, JF, Dyck, JD, Kobayashi, T, Benson, LN. Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. Circulation 1993;88: 621627.CrossRefGoogle ScholarPubMed
23.Prieto, RL, Foreman, CK, Cheatham, JP, Latson, LA. Intermediate-term outcome of transcatheter secundum atrial septal defect closure using the Bard clamshell septal umbrella. Am Heart J 1996;132: 13101312.Google Scholar
24.Masura, J, Gavora, P, Formanek, A, Hijazi, ZM. Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder-initial human experience. Cath Cardiovasc Diagn 1997;42: 388393.3.0.CO;2-7>CrossRefGoogle ScholarPubMed