Introduction
This chapter details the instrumentation for generating magnetic gradients and related technical issues. A basic understanding of gradient pulse generation provides insight into spectrometer limitations and related problems. The basic considerations and components of NMR probes and of the generation of high-intensity pulsed field gradients have been reviewed elsewhere. Many of the complications that affect PGSE measurements also apply to imaging experiments, consequently some of the solutions to the technical problems were developed with imaging in mind. Indeed, the design of a B0 gradient probe for diffusion measurements is essentially similar to that of an NMR imaging or microscopy probe except that the gradients used for the B0 gradient probe are often larger and greater precision is required in gradient pulse generation (i.e., pairs of gradient pulses need to be matched to the ppm level). Many high-resolution NMR probes come equipped with gradient coils capable of generating magnetic gradients in the range of 0.5 T m−1, whereas modern high-gradient diffusion probes are capable of generating gradients in excess of 20 T m−1 (Figure 5.1). There is also an interest in making probes capable of performing measurements on samples at high temperature and pressure and for use in solid-state studies.
To perform PGSE measurements, the spectrometer must be equipped with a current amplifier under the control of the acquisition computer which can send current pulses to a gradient coil placed around the sample. The hardware aspects of pulsed field gradient NMR have been discussed by numerous authors.
To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.
To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.