We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of the study was to investigate the detailed angularly dependent attenuation characteristics of three different commercial couch-tops: Varian IGRT, Qfix kVue Standard and Qfix kVue Dose Max couch-tops used in radiation therapy.
Materials and methods
The attenuation of photon beams by the treatment couch-tops was measured using a farmer chamber inserted at the centre of a 16 cm diameter cylindrical acrylic phantom for five different photon energies: 6 MV, 6FFF MV, 10 MV, 10FFF MV and 15 MV photon beams. The Varian IGRT couch-top has three different thicknesses thus attenuation measurements were done at the three different longitudinal locations. Measurements were made with the sliding support rails of the Qfix kVue Standard and Qfix kVue Dose Max couch-tops at both ‘rails-in’ and ‘rails-out’ positions. All measurements were taken for several projections through 360° movement of the gantry and for two different field sizes; 5×5 cm2 and 10×10 cm2.
Results and findings
The results indicate that the maximum attenuation of the Varian IGRT couch-top at the thin, medium and thick portions are 5·1, 5·7 and 8·9%, respectively, the Qfix kVue Standard couch with the rails-in and rails-out are 11·2 and 13·7%, respectively, and Qfix kVue Dose Max couch-top with rails-in and rails-out are 9·7 and 13·8%, respectively. The results from this study can be used to account for the couch-top attenuation during radiation treatment planning of patients treated with these couch-tops.