We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
1. The choice of method of oxygen administration is dependent largely on the desired fraction of inspired oxygen (FiO2).
2. To ensure delivery of a high FiO2 and avoid entrainment of room air, the delivery flow rate of oxygen must exceed the patient’s peak inspiratory flow rate.
3. Oxygen administration devices can be fixed or variable performance.
4. Variable performance devices can be adapted to allow for delivery of increased flows and/or higher FiO2.
5. Consideration of patient preference and comfort is an important deciding factor when selecting an oxygen administration device.
Pulse-oximetry has proven clinical value in Emergency Departments and Intensive Care Units. In the prehospital environment, oxygen is given routinely in many situations. It was hypothesized that the use of pulse oximeters in the prehospital setting would provide a measurable cost-benefit by reducing the amount of oxygen used.
Methods:
This was a prospective study conducted at 12 ambulance stations (average transport times >20 minutes). Standard care protocols and paramedic assessments were used to determine which patients received oxygen and the initial flow rate used. Pulse-oximetry measurements (oxygen-saturation measured by pulse oximetry) were then taken. If oxygen-saturation measured by pulse oximetry fell below 92% or rose above 96% (except in patients with chest pain), oxygen (O2) flow rates were adjusted. Costs of oxygen use were calculated: volume that would have been used based on initial flow rate; and volume actually used based on actual flow rates and transport time.
Methods:
A total of 1,907 patients were recruited. Oximetry and complete data were obtained on 1,787 (94%). Of these, 1,329 (74%) received O2 by standard protocol: 389 (27.5%) had the O2 flow decreased; 52 had it discontinued. Eighty-seven patients (6%) not requiring O2 standard protocol were hypoxemic (oxygen-saturation measured by pulse oximetry < 92%) by oximetry, and 71 patients (5%) receiving oxygen required flow rate increases. Overall, O2 consumption was reduced by 26% resulting in a cost-savings of $0.20 / patient. Prehospital pulse-oximetry allows unncessary or excessive oxygen therapy to be avoided in up to 55% of patients transported by ambulance and can help to identify suboptimally oxygenated patients (11%).
Conclusion:
Rationalizing the O2 administration using pulse-oximetry reduced O2 consumption. Other health care savings likely would result from a reduced incidence of suboptimal oxygenation. Oxygen cost-saving justifies oximeter purchase for each ambulance annually where patient volume exceeds 1,750, less frequently for lower call volumes, or in those services where the mean transport time is less than the 23 minute average noted in this study.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.