We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Hypoxia is a frequently reported complication during the intubation procedure in the emergency department (ED) and may cause bad outcomes. Therefore, oxygenation plays an important role in emergency airway management. The efficacy of oxygenation with high-flow nasal cannula (HFNC) in the ED has been studied, though the evidence is limited. The study aim was to compare two methods of preoxygenation in patients undergoing rapid sequence intubation (RSI) in the ED: (1) HFNC and (2) bag-valve mask (BVM) oxygenation.
Methods:
This is a single-center, prospective, randomized controlled trial (RCT) in adult ED patients requiring RSI. Patients were randomized to receive preoxygenation with either HFNC or BVM. While HFNC therapy was continued during the intubation procedure, BVM oxygenation was interrupted for laryngoscopy. The primary outcome was the lowest peripheral oxygen saturation (SpO2) level during intubation. Secondary outcomes were incidence of desaturation (SpO2<90%) and severe hypoxemia (SpO2<80%) throughout the procedure, intubation time, rate of failed intubation, and 30-day survival rates.
Results:
A total of 135 patients were randomized into two groups (HFNC n = 68; BVM n = 67). The median lowest SpO2 value measured during intubation was 96% (88.8%-99.0%) in the HFNC group and 92% (86.0%-97.5%) in the BVM group (P = .161). During the intubation procedure, severe hypoxemia occurred in 13.2% (n = 9) of patients in the HFNC group and 8.9% (n = 6) in the BVM group, while mild hypoxemia was observed in 35.8% (n = 24) of the BVM group and 26.5% (n = 18) of the HFNC group. However, there was no statistically significant difference between the groups in terms of hypoxemia development (P = .429 and P = .241, respectively). No significant difference was reported in the rate of failed intubation between the groups. Thirty-day mortality was observed in 73.1% of the BVM group and 57.4% of the HFNC group, with a borderline statistically significant difference (difference 15.7; 95% CI of the difference: −0.4 to 30.7; P = .054).
Conclusion:
The use of HFNC for preoxygenation, when compared to standard care with BVM oxygenation, did not improve the lowest SpO2 levels during intubation. Also, the use of HFNC during intubation did not provide benefits in reducing the incidence of severe hypoxemia. However, the 30-day survival rates were slightly better in the HFNC group compared to the BVM group.
The coronavirus disease 2019 (COVID-19) pandemic has challenged the ability of Emergency Medical Services (EMS) providers to maintain personal safety during the treatment and transport of patients potentially infected. Increased rates of COVID-19 infection in EMS providers after patient care exposure, and notably after performing aerosol-generating procedures (AGPs), have been reported. With an already strained workforce seeing rising call volumes and increased risk for AGP-requiring patient presentations, development of novel devices for the protection of EMS providers is of great importance.
Based on the concept of a negative pressure room, the AerosolVE BioDome is designed to encapsulate the patient and contain aerosolized infectious particles produced during AGPs, making the cabin of an EMS vehicle safer for providers. The objective of this study was to determine the efficacy and safety of the tent in mitigating simulated infectious particle spread in varied EMS transport platforms during AGP utilization.
Methods:
Fifteen healthy volunteers were enrolled and distributed amongst three EMS vehicles: a ground ambulance, an aeromedical-configured helicopter, and an aeromedical-configured jet. Sodium chloride particles were used to simulate infectious particles and particle counts were obtained in numerous locations close to the tent and around the patient compartment. Counts near the tent were compared to ambient air with and without use of AGPs (non-rebreather mask, continuous positive airway pressure [CPAP] mask, and high-flow nasal cannula [HFNC]).
Results:
For all transport platforms, with the tent fan off, the particle generator alone, and with all AGPs produced particle counts inside the tent significantly higher than ambient particle counts (P <.0001). With the tent fan powered on, particle counts near the tent, where EMS providers are expected to be located, showed no significant elevation compared to baseline ambient particle counts during the use of the particle generator alone or with use of any of the AGPs across all transport platforms.
Conclusion:
Development of devices to improve safety for EMS providers to allow for use of all available therapies to treat patients while reducing risk of communicable respiratory disease transmission is of paramount importance. The AerosolVE BioDome demonstrated efficacy in creating a negative pressure environment and workspace around the patient and provided significant filtration of simulated respiratory droplets, thus making the confined space of transport vehicles potentially safer for EMS personnel.
Following cardiac surgery, infants often remain endotracheally intubated upon arrival to the cardiac ICU. High-flow nasal cannula and non-invasive positive pressure ventilation are used to support patients following extubation. There are limited data on the superiority of either mode to prevent extubation failure.
Methods:
We conducted a single-centre retrospective study for infants (<1 year) and/or <10 kg who underwent cardiac surgery between 3/2019–3/2020. Data included patient and clinical characteristics and operative variables. The study aimed to compare high-flow nasal cannula versus non-invasive positive pressure ventilation following extubation and their association with extubation failure. Secondarily, we examined risk factors associated with extubation failure.
Results:
There were 424 patients who met inclusion criteria, 320 (75%) were extubated to high-flow nasal cannula, 104 (25%) to non-invasive positive pressure ventilation, and 64 patients (15%) failed extubation. The high-flow nasal cannula group had lower rates of extubation failure (11%, versus 29%, p = 0.001). Infants failing extubation were younger and had higher STAT score (p < 0.05). Compared to high-flow nasal cannula, non-invasive positive pressure ventilation patients were at 3.30 times higher odds of failing extubation after adjusting for patient factors (p < 0.0001).
Conclusions:
Extubation failure after cardiac surgery occurs in smaller, younger infants, and those with higher risk surgical procedures. Patients extubated to non-invasive positive pressure ventilation had 3.30 higher odds to fail extubation than patients extubated to high-flow nasal cannula. The optimal mode of respiratory support in this patient population is unknown.
The coronavirus disease 2019 (COVID-19) pandemic has created challenges in maintaining the safety of prehospital providers caring for patients. Reports have shown increased rates of Emergency Medical Services (EMS) provider infection with COVID-19 after patient care exposure, especially while utilizing aerosol-generating procedures (AGPs). Given the increased risk and rising call volumes for AGP-necessitating complaints, development of novel devices for the protection of EMS clinicians is of great importance.
Drawn from the concept of the powered air purifying respirator (PAPR), the AerosolVE helmet creates a personal negative pressure space to contain aerosolized infectious particles produced by patients, making the cabin of an EMS vehicle safer for providers. The helmet was developed initially for use in hospitals and could be of significant use in the prehospital setting. The objective of this study was to determine the efficacy and safety of the helmet in mitigating simulated infectious particle spread in varied EMS transport platforms during AGP utilization.
Methods:
Fifteen healthy volunteers were enrolled and distributed amongst three EMS vehicles: a ground ambulance, a medical helicopter, and a medical jet. Sodium chloride particles were used to simulate infectious particles, and particle counts were obtained in numerous locations close to the helmet and around the patient compartment. Counts near the helmet were compared to ambient air with and without use of AGPs (non-rebreather mask [NRB], continuous positive airway pressure mask [CPAP], and high-flow nasal cannula [HFNC]).
Results:
Without the helmet fan on, the particle generator alone and with all AGPs produced particle counts inside the helmet significantly higher than ambient particle counts. With the fan on, there was no significant difference in particle counts around the helmet compared to baseline ambient particle counts. Particle counts at the filter exit averaged less than one despite markedly higher particle counts inside the helmet.
Conclusion:
Given the risk to EMS providers by communicable respiratory diseases, development of devices to improve safety while still enabling use of respiratory therapies is of paramount importance. The AerosolVE helmet demonstrated efficacy in creating a negative pressure environment and provided significant filtration of simulated respiratory droplets, thus making the confined space of transport vehicles potentially safer for EMS personnel.
The aim of this study was to analyze the profile of chest injuries, oxygen therapy for respiratory failure, and the outcomes of victims after the Jiangsu tornado, which occurred on June 23, 2016 in Yancheng City, Jiangsu Province, China.
Methods:
The clinical records of 144 patients referred to Yancheng City No.1 People’s Hospital from June 23 through June 25 were retrospectively investigated. Of those patients, 68 (47.2%) sustained major chest injuries. The demographic details, trauma history, details of injuries and Abbreviated Injury Scores (AIS), therapy for respiratory failure, surgical procedures, length of intensive care unit (ICU) and hospital stay, and mortality were analyzed.
Results:
Of the 68 patients, 41 (60.3%) were female and 27 (39.7%) were male. The average age of the injured patients was 57.1 years. Forty-six patients (67.6%) suffered from polytrauma. The mean thoracic AIS of the victims was calculated as 2.85 (SD = 0.76). Rib fracture was the most common chest injury, noted in 56 patients (82.4%). Pulmonary contusion was the next most frequent injury, occurring in 12 patients (17.7%). Ten patients with severe chest trauma were admitted to ICU. The median ICU stay was 11.7 (SD = 8.5) days. Five patients required intubation and ventilation, one patient was treated with noninvasive positive pressure ventilation (NPPV), and four patients were treated with high-flow nasal cannula (HFNC). Three patients died during hospitalization. The hospital mortality was 4.41%.
Conclusions:
Chest trauma was a common type of injury after tornado. The most frequent thoracic injuries were rib fractures and pulmonary contusion. Severe chest trauma is usually associated with a high incidence of respiratory support requirements and a long length of stay in the ICU. Early initiation of appropriate oxygen therapy was vital to restoring normal respiratory function and saving lives. Going forward, HFNC might be an effective and well-tolerated therapeutic addition to the management of acute respiratory failure in chest trauma.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.