We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) improves motor outcomes in Parkinson’s disease (PD) but may have adverse long-term effects on specific cognitive domains. The aim of this study was to investigate the association between total electrical energy (TEED) delivered by DBS and postoperative changes in verbal fluency.
Methods
Seventeen PD patients undergoing bilateral STN-DBS were assessed with the Alternate Verbal Fluency Battery (AVFB), which includes phonemic (PVF), semantic (SVF), and alternate verbal fluency (AVF) tests, before surgery (T0) and after 6 (T1) and 12 months (T2). Bilateral TEED and average TEEDM were recorded at T1 and T2. For each AVFB measurement, changes from T0 to T1 (Δ-01) and from T0 to T2 (Δ-02) were calculated.
Results
At T1, PVF (p = 0.007) and SVF scores (p = 0.003) decreased significantly. TEED measures at T1 and T2 were unrelated to Δ-01 and Δ-02 scores, respectively. However, an inverse, marginally significant association was detected between the TEEDM and Δ-01 scores for the AVF (p = 0.041, against an αadjusted = 0.025).
Conclusions
In conclusion, the present reports provide preliminary evidence that TEED may not be responsible or only slightly responsible for the decline in VF performance after STN-DBS in PD.
Most of the implantable pulse generators (IPGs) in deep brain stimulation (DBS) used to date are non-rechargeable requiring regular replacements. IPG replacement is a minor surgical procedure, but adverse events including neurological worsening have been reported. In this study, we determine the possibility of neurological worsening after IPG replacement in Parkinson’s disease (PD) cases on chronic DBS therapy (CDT) and its electrophysiological basis along with the therapeutic interventions used to alleviate them.
Methods:
This study is a retrospective chart review of PD cases on CDT followed at London Movement Disorders Centre from January 2010 to December 2016. Included cases were those who underwent one or more IPG replacement.
Results:
A total of 45 PD cases on CDT underwent 62 IPG replacements involving 121 channels. Neurological worsening was observed in 16 (35.5%) cases following 17 (27.4%) IPG replacements, all following dual-channel IPG replacements. Tremor (41.2%), speech (35.3%), and gait (23.5%) worsened most commonly. Deviation from the pre-replacement parameters including voltage and impedance resulting in change in total electrical energy delivered (TEED) was the most common electrophysiological correlate, observed in 82.4% (14/17) IPGs having neurological worsening. This included switched laterality in a dual-channel IPG. Neurological worsening in the remaining 17.6% cases was hardware-related.
Conclusion:
Neurological worsening followed 27.4% of IPG replacements in PD cases on CDT with approximately 82.4% of these being avoidable by carefully monitoring stimulation parameters to match pre-replacement TEED values.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.