We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Patients with ventricular assist devices (VADs) represent a growing population presenting to Emergency Medical Services (EMS), but little is known about their prehospital care. This study aimed to characterize current EMS protocols in the United States for patients with VADs.
Methods:
States with state-wide EMS protocols were included. Protocols were obtained from the state EMS website. If not available, the office of the state medical director was contacted. For each state, protocols were analyzed for patient and VAD assessment and treatment variables.
Results:
Of 32 states with state-wide EMS protocols, 21 had VAD-specific protocols. With 17 (81%) states noting a pulse may not be palpable, protocols recommended assessing alternate measures of perfusion and mean arterial pressure (MAP; 15 [71%]). Assessment of VAD was advised through listening for pump hum (20 [95%]) and alarms (20 [95%]) and checking the power supply (15 [71%]). For treatment, EMS prehospital consultation was required to begin chest compression in three (14%) states, and mechanical (device) chest compressions were not permitted in two (10%) states. Contact information for VAD coordinator was listed in a minority of five (24%) states. Transport of VAD equipment/backup bag was advised in 18 (86%) states.
Discussion:
This national analysis of EMS protocols found VAD-specific EMS protocols are not universally adopted in the United States and are variable when implemented, highlighting a need for VAD teams to partner with EMS agencies to inform standardized protocols that optimize these patients’ care.