Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-27T16:22:50.346Z Has data issue: false hasContentIssue false

Effectiveness of near-UVA in SARS-CoV-2 inactivation

Published online by Cambridge University Press:  27 April 2023

Eleonora Frilli
Affiliation:
Post-Graduate School of Public Health, University of Siena, Siena, Italy
Davide Amodeo
Affiliation:
Hygiene and Preventive Medicine, University of Siena, Siena, Italy
Gabriele Cevenini
Affiliation:
Department of Medical Biotechnologies, University of Siena, Siena, Italy
Nicola Nante
Affiliation:
Post-Graduate School of Public Health, University of Siena, Siena, Italy Hygiene and Preventive Medicine, University of Siena, Siena, Italy
Gabriele Messina*
Affiliation:
Post-Graduate School of Public Health, University of Siena, Siena, Italy Hygiene and Preventive Medicine, University of Siena, Siena, Italy
*
Corresponding author: G. Messina; Email: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

This experimental study aimed to determine the activity of a near-UVA (405 nm) LED ceiling system against the SARS-CoV-2 virus. The ceiling system comprised 17 near-UVA LED lights with a radiant power of 1.1 W/each centred at 405 nm wavelength. A 96-multiwell plate, fixed to a wooden base, was inoculated with suspensions of VERO E6 cell cultures infected with SARS-CoV-2 virus and irradiated at a distance of 40 cm with a dose of 20.2 J/cm2 for 120 min. The collected suspensions were transferred to VERO cell culture plates and incubated for 3 days. The maximum measurable log reduction obtained, starting from a concentration of 107.2 TCID50/mL, was 3.0 log10 and indicated inhibition of SARS-CoV-2 replication by the near-UVA LED ceiling system. Near-UVA light at a 405-nm wavelength is emerging as a potential alternative treatment for localised infections and environmental decontamination because it is far less harmful to living organisms’ cells than UV-C irradiation.

Type
Original Paper
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press

Introduction

In December 2019, the first cases of COVID-19 disease were reported in the Hubei province, China, before becoming a global pandemic [Reference Zhu1]. The pathogen was identified as a beta-Coronavirus and designated as SARS-CoV-2 [Reference Gorbalenya2], which up to February 2023 had caused over 674 million infections with more than 6 million deaths worldwide [3]. Coronaviruses are mainly transmitted via respiratory droplets, but due to their prolonged viability in air and on inanimate surfaces, the virus particles may retain infectivity for several hours [Reference Van Doremalen4].

Irradiation using ultraviolet (UV) light is an established disinfection strategy for surfaces, air and water in hospitals to reduce the risk of infection [Reference Messina5]. It has been shown that coronaviruses are generally susceptible to UV radiation [Reference Heßling6] and in particular to UVC [Reference Kitagawa7]. UVC (wavelength 200–280 nm) has a greater germicidal effect than UVA (315–380 nm) and UVB (280–315 nm), as it acts directly on nucleic acid bases causing structural damage through photodimerisation. However, lately, near-UVA (405 nm) has emerged as a potential alternative treatment for localised infections and environmental decontamination [Reference Tomb8]. UVC and near-UVA irradiation are the most widely used light disinfection methods, with the latter being less detrimental to host cells [Reference Amodeo9]. Near-UVA, particularly of the 405 nm wavelength, exerts its antimicrobial effects through excitation of endogenous intracellular light receptors such as porphyrins and flavins [Reference Gwynne and Gallagher10] which then undergo an energy transfer process that leads to the generation of reactive oxygen species (ROS) resulting in lipid peroxidation, DNA damage, cell wall damage, and cellular apoptosis of microbial cells [Reference Wang11]. Several studies have explored the effects of near-UVA against bacterial and fungal pathogens [Reference Barneck12].

However, the ability of near-UVA to inactivate viruses, in particular, the SARS-CoV-2, which lack the porphyrin rings targets have received relatively little attention [Reference Tomb13], with the possible exception of the work of Vatter et al. [Reference Vatter, Hoenes and Hessling14] investigating the photoinactivation of a Coronavirus surrogate, phi6, using light at a 405 nm wavelength.

The aim of this study is to assess the virucidal activity of a 405 nm LED ceiling system directly against SARS-CoV-2 in vitro through its impact on the viability of a SARS-CoV-2 strain in a Tissue Culture Infective Dose 50% (TCID50%) model.

Methods

An experimental pre–post design study was undertaken, to assess the virucidal activity of a 405 nm LED ceiling system against SARS-CoV-2. The experiment took place partly in the Department of Molecular and Development Medicine at the University of Siena, for the experimental setting building stage, and partly in a Biosafety Level 3 Laboratory (BLS3) of Toscana Life Sciences (the technology park for the Southern Tuscany region, Italy), for in vitro tests.

405 nm light system and setup

The near-UV CEILING LAMP System at 405 nm (Figure 1) comprised 17 blue LED Luminus SST-10-UV lights (Luminus, Sunnyvale, CA, USA) positioned on a squared area of a printed circuit board (PCB); the distance between each LED was 6.5 cm. The LAMP System was supported by a wooden scaffold, fixed to a wooden base. The wooden structure, built for the experiment, consisted of four vertical supports, each 40 cm high, and a 36 cm x 36 cm wide wooden base the same size as the ceiling lamp used for the test. An outline of a multiwell plate, consisting of 24 flat bottom wells, was drawn in the central position of the base to facilitate correct positioning during the test.

Figure 1. Spectral behaviour as a function of wavelength (nm) of the near-UVA LEDs Luminus SST-10-UV (blue line).

Irradiance measurements were made using a spectrometer Avantes ULS2048CL-EVO (Avantes, Apeldoorn, the Netherlands) on the multiwell plate in the central position with plate cover on, as shown in Figure 2. Light distribution was not uniform over the whole plate and therefore, only the three central wells were used in each multiwell plate to minimise variation (maximum deviation in measured irradiance = 0.1 mW/cm2). Irradiance values and exposure times allowed calculation of the energy doses.

Figure 2. (a) Example of the 24 multiwell plate and selected wells used for the test (green spots C2 on the left, C3 in the centre, and C4 on the right). (b) Photometric measurements were carried out with the cosine corrector probe of the Avantes spectrophotometer to detect the irradiance values present in each of the three wells of the plate.

Cell culture and viruses

Vero E6 cells of the African green monkey kidney line (American Type Culture Collection [ATCC] #CRL-1586) were cultured in Dulbecco’s Modified Eagle’s Medium (DMEM) – high glucose (Euroclone, Pero, Italy) supplemented with 2 mM l-glutamine (Lonza, Milan, Italy), penicillin (100 U/mL) – streptomycin (100 μg/mL) (Lonza, Milan, Italy), and 10% foetal bovine serum (FBS) (Euroclone, Pero, Italy). Cell cultures were infected with the wild-type SARS CoV-2 2019 virus (2019-nCoV strain 2019-nCov/Italy-INMI1) (EVAg, Istituto Spallanzani, Rome, Italy). For virus propagation, monolayers of subconfluent Vero E6 cells were prepared in T175 flasks containing high-glucose DMEM medium.

Experimental method

One hundred microlitres of viral suspension (107.2 TCID50/mL), were inoculated in each plate well in phosphate-buffered saline (PBS; Oxoid, Basingstoke, UK). The plate was irradiated according to the protocol at a distance of 40 cm, for 30 and 120 min (Figure 3). For each exposure time, tests were carried out in triplicate. To do this, three aliquots of the viral suspension were delivered in left, central, and right positions of the plate (and exposed to the action of nUV with protocol timing. Three other aliquots were inoculated in another multiwell plate (shielded from light and not exposed to near-UVA) which served as a positive control to determine viral titre after recovery.

Figure 3. Experiment setting designed for the tests with the 405 nm LED ceiling system.

Following the exposure, the viral suspension was transferred to a 96-multiwell plate and 20 μL of suspension supplemented with 180 μL of high-glucose DMEM medium were transferred to each well of the first column and decimal dilutions were made. The suspensions were then inoculated into a new 96-multiwell plate into which the VERO E6 cell cultures were fixed, and then incubated for 3 days at 37 °C ± 2 °C at 5% CO2 in a humidified atmosphere. Each plate was examined with an optical microscope to assess the exhibited cytopathic effect (CPE). Viral titres were determined using a TCID50 assay. Experiments were repeated in triplicate, carried out independently from each other, and under the same measurement conditions. Untreated control cells were used to validate the test. The virus titre was calculated using Spearman–Karber’s formula [Reference Ramakrishnan15] and defined as the reciprocal of the highest viral dilution leading to at least 50% CPE in inoculated wells.

Results

The irradiance value measured on the three selected central wells of the multiwell plate was 2.8 mW/cm2 and the amount of total energy dose received in 30 and 120 min during exposure to near-UVA was equal to 5.05 and 20.20 J/cm2, respectively.

The results in Table 1 show that i) after an irradiation time of 30 min, the maximum measurable log reduction TCID50% was equal to 1.50; and ii) at 120 min, the maximum TCID50% was equal to 3.00. The percentage reductions and relative 95% confidence intervals were 96.17% [94.37%–97.39%] and 99.85% [99.78%–99.90%], at irradiation times of 30 and 120 min, respectively.

Table 1. Results of the 405 nm LED ceiling system at 40 cm from the multiwell plate after 30 and 120 min of near-UVA exposition

TCID, median tissue culture infectious dose.

Discussion

Since the beginning of the COVID-19 pandemic, several studies have explored different disinfection strategies against coronaviruses and some have involved light disinfection methods. Nevertheless, only a few studies have addressed the activity of near-UVA against viruses, particularly SARS-CoV-2 [Reference Tomb13, Reference Vatter, Hoenes and Hessling14].

Here, we have shown that a 405-nm LED ceiling system (Figure S1) is effective for the inactivation of SARS-CoV-2, in vitro. It was found that an energy dose of approximately 5 J/cm2, delivered a reduction of over 96% (1–2 log10), while a dose four times higher (about 20 J/cm2) almost reached a reduction of 99.9% (3 log10). These results are quite different from those observed by Tomb et al. [Reference Tomb16] who reported only a 0.3 log reduction with a dose of 306.2 J/cm2 in inactivation studies of Streptomyces phage phiC31 in phosphate-buffered saline. This could be due to the fact that phiC31, in contrast to SARS-CoV-2, is a non-enveloped dsDNA virus. Similarly, Vatter et al. [Reference Vatter, Hoenes and Hessling14] observed a 1 log reduction with a dose of 430 J/cm2 for a Coronavirus surrogate in PBS, but used a Pseudomonas syringae cell culture instead of our VERO E6 cells and likely also a different initial virus concentration. It is also noteworthy that the viral inoculum in our experiments was suspended in PBS rather than a nutrient solution to exclude the presence of external photosensitisers.

Since near-UVA requires longer exposure times or a higher radiant energy than UV-C for inactivating viruses, SARS-CoV-2 included [Reference Sabino17], it is less energy efficient when compared with other available pulsed-light technologies [Reference Buonanno18] particularly at the UV-C wavelength of mercury lamps (254 nm) [Reference Hadi19]. Although near-UVA can represent a feasible alternative because of its safety [Reference Yin and Dai20], it is important to note some possible negative effects of lights of a wavelength > 405 nm. The blue light band (415–455 nm) is harmful to retinal pigment epithelial cells [21], while wavelengths of 480–490 nm appear to influence physiological responses, such as mood, pupillary constriction [22], and circadian rhythm due to maximum suppression of melatonin at 484 nm [Reference Prayag23]. Nevertheless, it has been shown that mammalian keratinocytes and osteoblasts were more resistant than bacteria on exposure to bactericidal levels of 405 nm light, with no loss of cell viability [Reference McDonald24].

Furthermore, prolonged exposure of materials, such as plastic, paint, and other coating substances, to a 405 nm light induces less photo-degradation than UV-C irradiation (254–260 nm). Therefore, near-UVA light around 405-nm appears to be safe for continuous use even in the presence of people, with a quantity of light energy as a suitable trade-off between avoiding photobiological risks and ensuring a satisfactory disinfection level [Reference Messina25]. The distance at which the tests were carried out was limited to only 40 cm to safely manage the tests under the hood.

A limitation of this study is that the inactivation of SARS-CoV-2 was evaluated in a liquid media and not in aerosolised droplets, considering that they are the main infection route, so further studies are indicated as the near-UVA effects may depend on the substrate considered. Despite this, the ability to inactivate the virus on objects where the virus should settle or in environments makes this technology potentially useful to reduce the risk of infection.

Another important limit to this technology is linked to its photobiological risk. It is important to note that the wavelengths used encompassed a wider range, with peak inactivation at 405 nm, but potentially hazardous photobiological effects on skin and eyes [Reference Legierski and Michałek26] linked to wavelengths under 400 nm cannot be discounted and guidelines for the photobiological safety assessment of these radiation wavelengths have been published [27]. For this reason, it is necessary to manage aspects of safety with precautionary technical expedients by positioning the light sources at appropriate distances, and in compliance with international standards.

In conclusion, this study has demonstrated that near-UVA light is effective for the inactivation of SARS-CoV-2. Viability of the virus in a non-nutrient medium was reduced by 96.17 and 99.8% after exposures to the light source for 30 and 120 min, respectively. Application of this technology could reduce the risk of infection and increase the level of environmental hygiene, especially when associated with other physical or chemical disinfection methods.

Supplementary material

The supplementary material for this article can be found at https://doi.org/10.1017/S0950268823000560.

Data availability statement

The data that support the findings of this study are available from the corresponding author, G.M., upon reasonable request.

Author contribution

Conceptualisation of the study: G.C., G.M.; Data curation: E.F., G.C., G.M.; Investigation for the tests: E.F., D.A.; Methodology: E.F., D.A., G.M.; Resources: E.F.; Software acquisition of photonic measurements: G.C.; Supervision: G.C.; Writing – original draft preparation: G.C., N.N., G.M.; Writing – review and editing: E.F., D.A., G.C. All authors have read and agreed to the published version of the manuscript.

Funding statement

This research was partially funded by Ugolini srl, in agreement with the University of Siena.

Competing interest

Ugolini srl partially financed the University of Siena for research and development (R&D) activities related to devices adopting the described technology where G.M. was the principal investigator. R&D led to a patent application owned by Ugolini srl where G.C. and G.M. were co-inventors G.C. and G.M. are co-founders of the company egoHEALTH which was financed by Ugolini srl to cover minor parts of the investigation, included fees for patent activity issues. G.C. and G.M. did not receive any personal funds for the research. Ugolini srl had no role in any part of the manuscript.

References

Zhu, N, et al. (2020) A novel coronavirus from patients with pneumonia in China, 2019. New England Journal of Medicine 382, 727733.CrossRefGoogle ScholarPubMed
Gorbalenya, AE, et al. (2020) The species severe acute respiratory syndrome-related coronavirus: classifying 2019-nCoV and naming it SARS-CoV-2. Nature Microbiology 5, 536544.Google Scholar
COVID-19 Map Johns Hopkins Coronavirus Resource Center. Available at https://coronavirus.jhu.edu/map.html (accessed 20 February 2023).Google Scholar
Van Doremalen, N, et al. (2020) Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. New England Journal of Medicine 382, 15641567.CrossRefGoogle ScholarPubMed
Messina, G, et al. (2016) Time effectiveness of ultraviolet C light (UVC) emitted by light emitting diodes (LEDs) in reducing stethoscope contamination. International Journal of Environmental Research and Public Health 13, 940.CrossRefGoogle ScholarPubMed
Heßling, M, et al. (2020) Ultraviolet irradiation doses for coronavirus inactivation – Review and analysis of coronavirus photoinactivation studies. GMS Hygiene and Infection Control 15, Doc08.Google ScholarPubMed
Kitagawa, H, et al.(2021) Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination. American Journal of Infection Control 49, 299301.CrossRefGoogle ScholarPubMed
Tomb, RM, et al. (2018) Review of the comparative susceptibility of microbial species to photoinactivation using 380-480 nm violet-blue light. Photochemistry and Photobiology 94, 445458.CrossRefGoogle ScholarPubMed
Amodeo, D, et al. (2022) Efficacy of violet–blue light to inactive microbial growth. Scientific Report 12, 20179.CrossRefGoogle ScholarPubMed
Gwynne, PJ and Gallagher, MP (2018) Light as a broad-spectrum antimicrobial. Frontiers in Microbiology 9, 119.CrossRefGoogle ScholarPubMed
Wang, Y, et al. (2017) Antimicrobial blue light inactivation of pathogenic microbes: State of the art. Drug Resistance Updates 33–35, 1–22.CrossRefGoogle ScholarPubMed
Barneck, MD, et al.(2016) Violet 405-nm light: a novel therapeutic agent against common pathogenic bacteria. The Journal of Surgical Research 206, 316324.CrossRefGoogle Scholar
Tomb, RM, et al. (2017) New proof-of-concept in viral inactivation: Virucidal efficacy of 405 nm light against feline Calicivirus as a model for Norovirus decontamination. Food and Environmental Virology 9, 159167.CrossRefGoogle Scholar
Vatter, P, Hoenes, K and Hessling, M (2021) Photoinactivation of the coronavirus surrogate phi6 by visible light. Photochemistry and Photobiology 97, 122125.CrossRefGoogle ScholarPubMed
Ramakrishnan, MA (2016) Determination of 50% endpoint titer using a simple formula. World Journal of Virology 5, 8586.CrossRefGoogle ScholarPubMed
Tomb, RM, et al. (2014) Inactivation of Streptomyces phage ɸC31 by 405 nm light. Bacteriophage 4, e32129.CrossRefGoogle ScholarPubMed
Sabino, CP, et al. (2020) Light-based technologies for management of COVID-19 pandemic crisis. Journal of Photochemistry and Photobiology B 212, 111999.CrossRefGoogle ScholarPubMed
Buonanno, M, et al. (2020) Far-UVC light (222 nm) efficiently and safely inactivates airborne human coronaviruses. Scientific Reports 10, 10285.CrossRefGoogle ScholarPubMed
Hadi, J, et al. (2020) Control measures for SARS-CoV-2: A review on light-based inactivation of single-stranded RNA viruses. Pathogens (Basel Switzerland) 9, E737.Google ScholarPubMed
Yin, R, Dai, T, et al. (2013) Light based anti-infectives: Ultraviolet C irradiation, photodynamic therapy, blue light, and beyond. Current Opinion in Pharmacology 13, 731762.CrossRefGoogle ScholarPubMed
Eye complications of exposure to ultraviolet and blue-violet light. Points de Vue | International Review of Ophthalmic Optics. Available at https://www.pointsdevue.com/article/eye-complications-exposure-ultraviolet-and-blue-violet-light (accessed 20 February 2023).Google Scholar
The ‘Third’ Photoreceptor System of the Eye – Photosensitive Retinal Ganglion Cells. European Ophthalmic Review. Available at https://www.touchophthalmology.com/retina-vitreous/journal-articles/the-third-photoreceptor-system-of-the-eye-photosensitive-retinal-ganglion-cells/ (accessed 20 February 2023).Google Scholar
Prayag, AS, et al. (2019) Light modulation of human clocks, wake, and sleep. Clocks Sleep 1, 193208.CrossRefGoogle ScholarPubMed
McDonald, RS, et al. (2013) 405 nm light exposure of osteoblasts and inactivation of bacterial isolates from arthroplasty patients: potential for new disinfection applications? European Cells and Materials 25, 204214.CrossRefGoogle ScholarPubMed
Messina, G, et al. (2023) Safer school with near-UV technology: novel applications for environmental hygiene. Journal of Environmental Health Science and Engineering 21, 157165.CrossRefGoogle ScholarPubMed
Legierski, M and Michałek, P (2018) Assessment of photobiological safety of passing beam and driving beam headlamps with different light sources. IOP conference series: Material Science and Engineering 421, 032016.Google Scholar
Photobiological Safety of Lamps and Lamp Systems | CIE. Available at http://cie.co.at/publications/photobiological-safety-lamps-and-lamp-systems (accessed 20 February 2023).Google Scholar
Figure 0

Figure 1. Spectral behaviour as a function of wavelength (nm) of the near-UVA LEDs Luminus SST-10-UV (blue line).

Figure 1

Figure 2. (a) Example of the 24 multiwell plate and selected wells used for the test (green spots C2 on the left, C3 in the centre, and C4 on the right). (b) Photometric measurements were carried out with the cosine corrector probe of the Avantes spectrophotometer to detect the irradiance values present in each of the three wells of the plate.

Figure 2

Figure 3. Experiment setting designed for the tests with the 405 nm LED ceiling system.

Figure 3

Table 1. Results of the 405 nm LED ceiling system at 40 cm from the multiwell plate after 30 and 120 min of near-UVA exposition

Supplementary material: Image

Frilli et al. supplementary material

Frilli et al. supplementary material

Download Frilli et al. supplementary material(Image)
Image 168.3 KB