Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-27T22:26:46.059Z Has data issue: false hasContentIssue false

A new ice mill allows precise concentration determination of methane and most probably also other trace gases in the bubble air of very small ice samples

Published online by Cambridge University Press:  20 January 2017

Andreas Fuchs
Affiliation:
Physikalisches Institut, Universität Bern, CH-3012 Bern, Switzerland
Jakob Schwander
Affiliation:
Physikalisches Institut, Universität Bern, CH-3012 Bern, Switzerland
Bernhard Stauffer
Affiliation:
Physikalisches Institut, Universität Bern, CH-3012 Bern, Switzerland
Rights & Permissions [Opens in a new window]

Abstract

A new extraction system has been constructed and tested which allows the extraction of gases from air bubbles in ice without melting it. An ice sample of up to 20 g is crushed in a sealed container by a milling cutter and the gas escaping from the opened bubbles is flushed with helium to a Porapak column where it is stored until its injection into the gas Chromatograph. To avoid any contamination with CH4 produced by friction in the gear section, a helium-flushed rotary feed-through is used. CH4 analyses on ice samples of about 10 g from the last 1000 years give precise and reproducible results. In the future, it is planned to measure also the CO2 and N2O concentrations on the same sample.

Type
Instruments and Methods
Copyright
Copyright © International Glaciological Society 1993

Introduction

During the formation of glacier ice, air is separated from the atmosphere and enclosed in bubbles. At locations with a low mean annual air temperature, ice is formed by sintering of dry cold firn. In this case, the air in the bubbles has approximately the same composition as the air at the time of ice formation (Reference Stauffer and OeschgerStauffer and Oeschger, 1985). To obtain information about ancient atmospheric compositions, air samples from ice formed in that epoch have to be extracted and analysed. Both steps, the extraction and the analyses of the air samples, need sophisticated methods. In this paper a new technique for extraction is discussed.

Air can be extracted by melting the ice under a vacuum and by collecting the escaping air by compression or condensation (Reference Berner, Oeschger and StaufferBerner and others, 1980; Reference Delmas, Ascencio and LegrandDelmas and others, 1980; Reference Craig and ChouCraig and Chou, 1982; Reference Rasmussen and KhalilRasmussen and Khalil, 1984). However, the meltwater can interact with the air and alter its composition. For CO2 analyses, wet extraction is unsuitable. Therefore, several techniques for dry extraction have been suggested (Reference Raynaud, Delmas, Ascencio and LegrandRaynaud and others, 1982; Reference Neftel, Oeschger, Schwander, Stauffer and ZumbrunnNeftel and others, 1982; Reference Barnola, Raynaud, Neftel and OeschgerBarnola and others, 1983; Reference Etheridge, Pearman and SilvaEtheridge and others, 1988). In all cases, the ice sample is ground mechanically under a vacuum to small grains or powder and the escaping gas is either collected by compression or condensation, or it is flushed from the extraction compartment with an inert gas.

In our laboratory, we use a small crushing device for ice samples of about 20 g together with a laser absorption spectrometer to measure the CO2 concentration (Reference Zumbrunn, Neftel and OeschgerZumbrunn and others, 1982). A second dry-extraction device is a sort of ice mill for ice samples with a size of 500 g. It is mainly used for 13C analyses on CO2 extracted from ice (Reference Moor and StaufferMoor and Stauffer, 1984).

For the CH4 analyses, samples of several hundred grams of ice are either milled in the ice mill mentioned above or melted in a wet-extraction system. In both cases, the air is analysed by a gas Chromatograph (Reference Stauffer, Fischer, Neftel and OeschgerStauffer and others, 1985, Reference Stauffer, Lochbronner, Oeschger and Schwander1988).

To determine CO2 and CH4 and probably N2O, on the same small sample of up to 20 g with a gas Chromatograph, a new extraction method had to be developed. First, a chopper was built and tested; when in operation, it produced contaminating CH4 and CO2. Finally, a machine which is more similar to our milling device but which is equipped with a helium-flushed rotary-motion feed-through worked without any CH4 contamination. Before describing the latter system, we briefly discuss the chopping system, so that others may be aware of the contamination problems we have encountered with it.

CH4 Contamination in the Chopping Device

From tests with the existing ice mill, we knew that friction between stainless steel and silver-coated stainless steel produces CH4. Because the new machine was planned to extract the air from small samples, any contamination had to be avoided and therefore the moving stainless-steel surfaces were separated by rings made from polyoxy-methylene (Delrin). In tests without ice and with constant milling frequency, the CH4 contamination increased with the number of strokes and the CO2 contamination increased with time and temperature.

Because gliding rings made from polyimide (Vespel) and brass also produced CH4, other pairs of materials were tested for contaminating under friction. But no combination of brass, chromium-plated brass and Plexiglas with brass, chromium-plated brass, copper, aluminium, teflon-coated aluminium, polyoxymethylene and glass proved to be non-contaminating.

The Principle of a Milling Device with a Helium-Flushed Rotary-Motion Feed-Through

Each milling tool needs an axis which rotates in a bearing. Rotation in a bearing causes friction, and friction between the metals we tested or between those metals and synthetics causes methane contamination. Instead of trying to avoid this contamination, there is also the possibility of pumping away the methane. The milling tool is mounted on a very stable shaft. The shaft rotates at its other end in precision bearings. Between the milling tool and the bearings, the shaft rotates in a cylinder without touching its wall (Fig. 1). Helium is injected into the middle of this cylinder and flows between the cylinder and the shaft, partly in the direction of the bearings and partly in the direction of the compartment with the milling tool and the ice sample. The helium flowing towards the bearings is pumped away. The helium flowing through the sample compartment is used to flush the extracted air sample to the cryofocusing device. The principle of this system is very simple but the requirements in respect of precision and stability of the shaft and the bearings are difficult to attain. The clearance between shaft and cylinder should be narrow so that not too much helium is required. On the other hand, the shaft must not touch the wall of the cylinder if the ice sample is pressed against the milling tool.

Fig. 1. Helium-flushed rotary-motion feed-through. The helium flow Inl (typically 200ml min−1) branches along the shaft to the sample compartment and to the pump. Dimensions: L = 85.5 mm, d1 = 49.5 mm, d2 = 31 mm, D = 30 mm and δ = 0.085 mm. The location of Figure 1 in Figure 2 is indicated by the shaded area

The leakage rate of the helium-flushed rotary-motion feed-through, negligible in our system, is given by Acv / [exp(vd/K) − 1]; A, cross-section of flow; c, concentration of gas; ν, velocity of the helium flow; d, length of the seal; k, diffusion constant of the gas in the helium.

Description of the Milling Device and the Extraction Procedure

The extraction system is schematically shown in Figure 2. It consists mainly of the milling device where the air escapes from the mechanically opened bubbles and a “cryofocusing” system where the air sample is collected and stored until its injection into the gas Chromatograph.

Fig. 2. Schematic arrangement of the ice mill, cold trap and cryofocusing column. The shaded area indicates the location of the helium-flushed rotary-motion feed-through (Fig. 1).

The main parts of the milling device are the sample compartment with the milling cutter, the helium-flushed rotary feed-through and the bearing section. The sample compartment, made of stainless steel, is designed for ice samples up to a size of 20 mm × 20 mm × 60 mm. This amount of ice is needed in order to measure accurately not only the pre-industrial CH4 concentrations but also the much lower concentrations during glacial periods. The ice is pressed against the milling cutter by its own weight and by an additional weight on top of the sample. The cutter is driven either by hand or a disc motor. The rotary-motion feed-through, made of stainless steel, has a length of 85.5 mm. The shaft has a diameter of 30 mm, the clearance between shaft and cylinder is 0.085 mm. The inlet for the helium is near the centre of the section. About 200ml min−1 helium (In1) are used, of which 100ml min−1 flow in the direction of the bearing section and prevent atmospheric air or any contamination produced in the bearing section from flowing or diffusing into the sample compartment. The flow in this branch of the feed-through section is controlled by a needle valve in the tube to the pump. The remaining 100 ml min−1 of helium enter the sample compartment, adding to the 50 ml min−1 helium of flow In2. Mixed with helium, the extracted air (or standard gas that was injected into flow In2 for calibration) passes via Out3 and the cold trap to the cryofocusing column.

The cyrofocusing system consists of a stainless steel 75 mm × 2 mm i.d. Porapak Q column. The extracted air is collected at liquid-nitrogen temperature. At the beginning of the analysis, the Porapak Q, column is switched to the carrier-gas flow of the gas Chromatograph (7 ml min−1 ). There it is heated in less than 15s to 85°C to release the air on to the separation column.

At the beginning of an extraction procedure, the ice sample is loaded into the sample compartment and the compartment is sealed. To remove the atmospheric air from the sample compartment, it is flushed for several minutes with helium at a very high flow rate. After this operation, carrier gas (purified helium with trace-gas impurities below our detection limits) passes through the system with the given flow rates, and the cryofocusing system collects possible impurities for 4 min. If no impurities can be detected, an amount of air similar to that expected to come from the sample with standard composition is inserted through tube In2. Then, the cryofocusing system collects again for 4 min. The analysis of the collected standard gas with the gas Chromatograph serves as a calibration. Now, the ice sample is crushed and the escaping air is collected again for 4 min on the cryofocusing column and analysed with the gas Chromatograph.

After the sample analysis, the measurement with standard gas is repeated. The frequency of the motor, as well as the duration of its operation, is held constant with all the samples of a series. A sample of 20 mm × 20 mm × 30 mm real ice is usually milled in 2 min at approximately 375r.p.m. (cutter with six blades). The total time needed for the analysis of one ice sample, including loading of the sample, the different calibration measurements and the removal of the ice chips from the sample compartment, takes about 1 h.

Test Results

The Porapak Q column was tested for its absorption capacities for the major air constituents and traces of CH4 and CO2. It works well within the range of air amounts and trace concentrations expected in ice-age and Holocene ice samples if it is colder than −170°C.

The cold trap, held at −100° C, does not alter the air composition.

Tests on the ice mill have been made with pure single-crystal ice of a size up to 20 g. There was still a detectable contamination with CH4 produced by the friction of the stainless-steel weight on top of the ice sample on the wall of the sample compartment. After the metal weight was replaced by one which is surrounded by single-crystal ice, the contamination by CH4 was below the detection limit of 20 ppb.

To test the system as a whole, ice samples from Siple Station, West Antarctica, and Summit, Greenland (EUROCORE), were analysed. The measurements show that the reproducibility of the analyses is better than 15 ppb, which is better than any precision achieved previously (Reference Rasmussen and KhalilRasmussen and Khalil, 1984; Reference Stauffer, Fischer, Neftel and OeschgerStauffer and others, 1985, Reference Stauffer, Lochbronner, Oeschger and Schwander1988; Reference Raynaud, Chappellaz, Barnola, Korotkevich and LoriusRaynaud and others, 1988; Reference Chappellaz, Barnola, Raynaud, Korotkevich and LoriusChappellaz and others, 1990). However, there was a difference in the absolute CH4-concentration values compared to earlier measurements on larger samples (Reference Stauffer, Fischer, Neftel and OeschgerStauffer and others, 1985), even though the same standard gas was used. The new measurements were between 50 and 100 ppb lower. Tests showed that this discrepancy originated from contamination of the standard gas for calibration when it was injected into the sample compartment. Notably, the operation of a few stainless steel valves in the inlet system produces a detectable CH4 contamination. To avoid this source of contamination in the future, we shall install teflon-coated valves that are similai to those on the gas Chromatograph and that have been proved to work.

The tests undertaken to prove the suitability of the new, small ice mill for CH4 analyses are listed in Table 1.

Table 1. Listed are the tests of the ice mill without those to test the weight that pushes the ice sample on to the milling cutter. They were undertaken to check the suitability of the new ice mill for CH4 analyses. Milling of a piece of single-crystal ice takes longer than milling a piece of real ice having the same geometry. The samples of real ice are therefore contaminated with less than 20 ppb CH4. Every experiment with real ice consists of at least one blank measurement, two standard gas injections to calibrate and one run with milling of the sample

CO2 contamination in the order of several per cent is due to desorption of CO2 from the walls of our system. It is larger than in our crushing system used with the laser absorption spectrometer because the milling and air-collection times are longer. The reproducibility of the CO2-concentration measurements is about 7 ppm and the mean value is about 10 ppm higher than that measured with the laser absorption spectrometer or the ice mill for 500 g samples and the gas Chromatograph (Reference Stauffer, Fischer, Neftel and OeschgerStauffer and Oeschger, 1985). If the sample compartment is cooled down to −40°C, the contamination decreases from 10 ppm to below the detection limit, which is about 0.3 ppm. Cooling of the mill (Reference Ocampo and KlingerOcampo and Klinger, 1982) and improvements in the cryofocusing device should result in better reproducibility. At present, the measurements of the CO2 concentration in air extracted from ice samples of 20 g is more precise and faster by using our laser absorption spectrometer than with the gas Chromatograph and the new extraction system. However, there is a considerable advantage by measuring several components on the same sample. Therefore, we shall still try to improve the precision of CO2 measurement by using the new method.

Preliminary tests on N2O are promising and indicate that our system is also suitable for concentration measurements of this important atmospheric component (Reference Zardini, Raynaud, Scharffe and SeilerZardini and others, 1989).

Final Remarks

The tests show that the new extraction device is well suited to measurements of the CH4 concentration in air of ice samples of a size up to 20 g. The CO2 and N2O concentrations are measured simultaneously but with less precision.

The cryofocusing device couples the mill to the gas Chromatograph. A re-design of that device would allow use of the mill with gas-detection systems using no carrier gas.

Notes

Since the submission of this paper in 1991, the CH4-producing stainless-steel valves have been replaced and, after several tests that showed that the contamination had disappeared, the series of EUROCORE samples was re-measured. The new results confirm the precision achieved in the first series.

Acknowledgements

The construction of the new extraction device was supported by the Swiss National Science Foundation and the “Bundesamt für Bildung und Wissenschaft” in the frame of EUROCORE, a COST 611 project. The authors would like to thank K. Grossenbacher for constructing the cryofocusing device, H. Rufli for constructing the ice mill and T. Blunier for his help with the test measurements.

The accuracy of references in the text and in this list is the responsibility of the authors, to whom queries should be addressed.

References

Barnola, J.M., Raynaud, D., Neftel, A. and Oeschger, H. 1983. Comparison of CO2 measurements by two laboratories on air from bubbles in polar ice. Nature, 303(5916), 410413.CrossRefGoogle Scholar
Berner, W., Oeschger, H. and Stauffer, B. 1980. Information on the CO2 cycle from ice core studies. Radiocarbon, 22(2), 227235.CrossRefGoogle Scholar
Chappellaz, J., Barnola, J. M., Raynaud, D., Korotkevich, Ye. S. and Lorius, C. 1990. Ice-core record of atmospheric methane over the past 160,000 years. Nature, 345(6271), 127131.Google Scholar
Craig, H. and Chou, C. C. 1982. Methane: the record in polar ice cores. Geophys. Res. Lett., 9(11), 12211224.CrossRefGoogle Scholar
Delmas, R., Ascencio, J. M. and Legrand, M. 1980. Polar ice evidence that atmospheric CO2 20,000 yr BP was 50% of present. Nature, 284(5752), 155157.CrossRefGoogle Scholar
Etheridge, D.M., Pearman, G.I. and Silva, F. de 1988. Atmospheric trace-gas variations as revealed by air trapped in an ice core from Law Dome, Antarctica. Ann. Glacial., 10, 2833.Google Scholar
Moor, E. and Stauffer, B. 1984. Instruments and methods. A new dry extraction system for gases in ice. J. Glaciol., 30(106), 358361.CrossRefGoogle Scholar
Neftel, Α., Oeschger, Η. Schwander, J., Stauffer, Β. and Zumbrunn, R. 1982. Ice core sample measurements give atmospheric CO2 content during the past 40,000 yr. Nature, 295(5846), 220223.Google Scholar
Ocampo, J. and Klinger, J. 1982. Adsorption of N2 and CO2 on ice. J. Colloid Interface Sei., 86(2), 377383.Google Scholar
Rasmussen, R. Α. and Khalil, M.A.K. 1984. Atmospheric methane in the recent and ancient atmospheres: concentrations, trends, and interhemispheric gradient. J. Geophjs. Res., 89(D7), 11,59911,605.Google Scholar
Raynaud, D., Delmas, D., Ascencio, J. M. and Legrand, M. 1982. Gas extraction from polar ice cores: a critical issue for studying the evolution of atmospheric CO2 and ice-sheet surface elevation. Ann. Glaciol., 3, 265268.Google Scholar
Raynaud, D., Chappellaz, J., Barnola, J.M., Korotkevich, Ye. S. and Lorius, C. 1988. Climatic and CH4 cycle implications of glacial-interglacial CH4 change in the Vostok ice core. Nature, 333(6174), 655657.Google Scholar
Stauffer, B. and Oeschger, H. 1985. Gaseous components in the atmosphere and the historic record revealed by ice cores. Ann. Glaciol., 7, 5459.CrossRefGoogle Scholar
Stauffer, B., Fischer, G., Neftel, A. and Oeschger, H. 1985. Increase of atmospheric methane recorded in Antarctic ice core. Science, 229(4720), 13861388.CrossRefGoogle ScholarPubMed
Stauffer, B., Lochbronner, E., Oeschger, H. and Schwander, J. 1988. Methane concentration in the glacial atmosphere was only half that of the preindustrial Holocene. Nature, 332(6167), 812814.Google Scholar
Zardini, D., Raynaud, D., Scharffe, D. and Seiler, W. 1989. N2O measurements of air extracted from Antarctic ice cores: implication on atmospheric N2O back to the last glacial–interglacial transition. J. Atmos. Chem., 8(2), 189201.CrossRefGoogle Scholar
Zumbrunn, R., Neftel, A. and Oeschger, H. 1982. CO2 measurements on 1-cm3 ice samples with an IR laser-spectrometer (IRLS) combined with a new dry extraction device. Earth Planet. Sci. Lett., 60(2), 318324.Google Scholar
Figure 0

Fig. 1. Helium-flushed rotary-motion feed-through. The helium flow Inl (typically 200ml min−1) branches along the shaft to the sample compartment and to the pump. Dimensions: L = 85.5 mm, d1 = 49.5 mm, d2 = 31 mm, D = 30 mm and δ = 0.085 mm. The location of Figure 1 in Figure 2 is indicated by the shaded area

Figure 1

Fig. 2. Schematic arrangement of the ice mill, cold trap and cryofocusing column. The shaded area indicates the location of the helium-flushed rotary-motion feed-through (Fig. 1).

Figure 2

Table 1. Listed are the tests of the ice mill without those to test the weight that pushes the ice sample on to the milling cutter. They were undertaken to check the suitability of the new ice mill for CH4 analyses. Milling of a piece of single-crystal ice takes longer than milling a piece of real ice having the same geometry. The samples of real ice are therefore contaminated with less than 20 ppb CH4. Every experiment with real ice consists of at least one blank measurement, two standard gas injections to calibrate and one run with milling of the sample