Hostname: page-component-586b7cd67f-tf8b9 Total loading time: 0 Render date: 2024-11-24T02:24:57.994Z Has data issue: false hasContentIssue false

A novel method to visualize liquid distribution in snow: superimposition of MRI and X-ray CT images

Published online by Cambridge University Press:  21 December 2023

Satoru Yamaguchi*
Affiliation:
Snow and Ice Research Center, National Research Institute for Earth Science and Disaster Resilience, Nagaoka, Niigata, Japan
Satoru Adachi
Affiliation:
Shinjo Cryospheric Environment Laboratory, Snow and Ice Research Center, National Research Institute for Earth Science and Disaster Resilience, Shinjo, Yamagata, Japan
Sojiro Sunako
Affiliation:
Snow and Ice Research Center, National Research Institute for Earth Science and Disaster Resilience, Nagaoka, Niigata, Japan
*
Corresponding author: Satoru Yamaguchi; Email: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

The relationship between the behavior of water in snow and its microstructure is crucial to improve the prediction of wet snow disasters. X-ray computed tomography (X-ray CT) is frequently used to observe snow microscopically. However, distinguishing between ice and water in the X-ray images is difficult because ice exhibits an X-ray absorption coefficient similar to that of water. In contrast, magnetic resonance imaging (MRI) acquires nuclear magnetic resonance (NMR) signals of protons in a liquid and visualizes the NMR signal intensity, enabling discrimination between water and ice signals. However, snow grains and pore spaces cannot be distinguished in MRI images because they do not generate NMR signals.

To investigate the relationship between the microstructure of snow and the distribution of liquids in snow, we developed a novel method that combines X-ray CT and MRI images to compensate for the disadvantages associated with each method. Using this method, we successfully visualized where liquid (C12H24) occupied pore spaces. We also showed the possibility of using C12H24 instead of water to obtain water retention curve of snow cover, which is a fundamental aspect of hydraulic properties. Although there is room for improvement in the visualization of water in snow, such as shortening the imaging time to escape snow metamorphosis and image superimposition methods, this method is expected to effectively elucidate the behavior of water in snow and clarify the characteristics of wet snow.

Type
Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
Copyright © The Author(s), 2023. Published by Cambridge University Press on behalf of The International Glaciological Society

1. Introduction

An accurate description of meltwater movement in snow cover is essential to improve the prediction of wet snow disasters. Percolating water occasionally ponds at the boundary between snow layers with different characteristics caused by capillary barriers (e.g. Khire and others, Reference Khire, Benson and Bosscher2000; Waldner and others, Reference Waldner, Schneebeli, Schultze-Zimmermann and Flühler2004; Avanzi and others, Reference Avanzi, Hirashima, Yamaguchi, Katsushima and Michele2016). Water ponding above a capillary barrier is prone to have an unstable flow, subsequently resulting in a preferential flow path. Consequently, heterogeneous water discharge occurs from the snow (e.g. Marsh and Woo, Reference Marsh and Woo1984, Reference Marsh and Woo1985; Nomura, Reference Nomura1994; Yamaguchi and others, Reference Yamaguchi, Hirashima and Ishii2018). This heterogeneous water discharge affects the timing of full-depth avalanches because it is occasionally triggered by water reaching the bottom of the snow cover. Moreover, snow grain characteristics change rapidly under wet conditions, and the snowpack mechanical properties, stability, and optical properties alter with liquid water content (Marshall and others, Reference Marshall, Conway and Rasmussen1999; Baggi and Schweizer, Reference Baggi and Schweizer2008; Mitterer and others, Reference Mitterer, Hirashima and Schweizer2011; Techel and Pielmeier, Reference Techel and Pielmeier2011; Dietz and others, Reference Dietz, Kuenzer, Gessner and Dech2012; Mitterer and Schweizer, Reference Mitterer and Schweizer2013; Schmid and others, Reference Schmid2015). Therefore, knowledge of the distribution of liquid water content in snow cover resulting from water movement is also crucial for understanding snow properties.

Two crucial physical quantities are considered in the study of the movement of water in snow. The first is the water retention curve (WRC), which is also known as the ‘water content–matric potential curve’, or ‘capillary pressure–saturation relationship’, which shows the relationship between the liquid water content and matric potential, and is a fundamental aspect of hydraulic properties in porous media (Klute, Reference Klute and Klute1986). The second is the saturated hydraulic conductivity (Ks), which indicates the ability of porous materials such as soil and rock to transmit water. For example, previous studies (Yamaguchi and others, Reference Yamaguchi, Katsushima, Sato and Kumakura2010, Reference Yamaguchi, Watanabe, Katsushima, Sato and Kumakura2012) have measured and analyzed the snow WRC using bulk methods. Based on their data, they proposed models to characterize the WRC of snow in terms of grain size and density. To study Ks using bulk methods, certain studies (Shimizu, Reference Shimizu1970; Calonne and others, Reference Calonne2012) have measured the air permeability of snow and then modeled the Ks of snow in terms of grain size and density. Combining these models with the bulk method has successfully reproduced the 1-D water movement in the snow to a certain extent (Hirashima and others, Reference Hirashima, Yamaguchi, Sato and Lehning2010; Wever and others, Reference Wever, Fierz, Mitterer, Hirashima and Lehning2014, Reference Wever2015). However, water in natural snow infiltrates selectively and not uniformly, resulting in a nonuniform distribution of water in the snow. Consequently, runoff from the bottom of the snowpack occasionally exhibits heterogeneity (Yamaguchi and others, Reference Yamaguchi, Hirashima and Ishii2018). To describe these complex water movements in snow, Hirashima and others (Reference Hirashima, Yamaguchi and Katsushima2014) developed a multidimensional water transport model and successfully reproduced heterogeneous water infiltration in the snow. Their model is innovative because it represents water movement in snow in 3D; however, the equations used in the model are based on the bulk method, which does not directly account for the effects of snow microstructure and porosity. As an example of the direct observation of detailed water movement in snow, Walter and others (Reference Walter, Horender, Gromke and Lehning2013) measured pore-scale water flow through snow using Fluorescent Particle Tracking Velocimetry. Their results indicated that water in snow exhibits highly complex movements and can flow upward against gravity, even when saturated. Katsushima and others (Reference Katsushima, Adachi, Yamaguchi, Ozeki and Kumakura2020) showed that the finger flow occurring during penetration into dry snow is a crucial factor in channel development and that the penetration process is strongly influenced by differences in the vertical microporous structure. Therefore, understanding water movement in a natural snowpack requires a microscale perspective that clarifies both the pore structure and the layer structure. To advance our understanding in this field, methods need to be developed to directly measure the relationship between water movement and snow microstructure. Recently, several novel methods, such as using Raman spectroscopy (Maggiore and others, Reference Maggiore, Tommasini and Ossi2022) and near-infrared hyperspectral reflectance (Donahue and others, Reference Donahue, Skiles and Hammonds2022), have been applied to measure detailed water distribution in snow; however, these methods can not directly obtain information on 3D snow microstructure properties, such as pore size distribution, that control water movement.

There are two methods available for examining snow structure at high resolution. One method uses X-ray computed tomography (X-ray CT), and the other uses magnetic resonance imaging (MRI). X-ray CT has a very high spatial resolution, ranging from tens to several micrometers, and is applicable in various fields, including the human body and electronic components. Therefore, it is the most versatile, nondestructive and high-resolution method for measuring 3D structures. Several studies have been conducted on snow imaging, analysis and the developing of experimental tools using X-ray CT (e.g. Coleou and others, Reference Coleou, Lesaffre, Brzoska, Ludwig and Boller2003; Schneebeli, Reference Schneebeli2004; Heggli and others., Reference Heggli2011; Hagenmuller and others, Reference Hagenmuller, Chambon, Lesaffre, Flin and Naaim2013; Wiese and Shneebeli, Reference Wiese and Shneebeli2017), and various studies have discussed snow characteristics from a microscopic perspective (e.g. Kaempfer and Schneebeli, Reference Kaempfer and Schneebeli2007; Löwe and others, Reference Löwe, Spiegel and Schneebeli2011; Calonne and others, Reference Calonne2012; Pinzer and others, Reference Pinzer, Schneebeli and Kaempfer2012). However, these studies were limited to dry snow because the difference in CT values between water and ice is marginal, and the boundary between water and ice is submerged in noise and cannot be clearly distinguished. In contrast, MRI is a method of acquiring 3D internal information regarding an imaging target using nuclear magnetic resonance (NMR), which is a phenomenon that interacts with the electromagnetic waves of a frequency specific to atomic nuclei in a static magnetic field; the NMR signal of hydrogen atoms in liquid water has been acquired and imaged. Therefore, when a wet snow sample is imaged using MRI, no NMR signal is acquired from snow grains (solid water) or pore spaces, and the NMR signal is detected from only the liquid water contained in the sample. Recently several wet snow studies have been conducted using MRI (Adachi and others, Reference Adachi2009, Reference Adachi, Yamaguchi, Ozeki and Kose2017, Reference Adachi, Yamaguchi, Ozeki and Kose2019, Reference Adachi, Yamaguchi, Ozeki and Kose2020; Katsushima and others, Reference Katsushima, Adachi, Yamaguchi, Ozeki and Kumakura2020).

Considering the strengths of X-ray CT and MRI, we developed a novel method to directly observe pore spaces that are filled with liquid. The advantage of our new method is that we can directly measure the relationship between the hydraulic properties and the microstructure at a high spatial resolution. In this study, we first introduce the methodology of our novel method and discuss the measurement errors at this stage. Next, we present preliminary results, including actual measurements using our method, followed by the discussion of the results. Finally, we discuss strategies for improving the utilization of water in our methods.

2. Methods

2.1 Devices

In this study, we used two nondestructive 3D imaging techniques. One was an X-ray CT system used to analyze the microstructure of a snow sample before wetting. The other was an MRI to analyze the distribution of liquid in snow after wetting. The X-ray CT system was μCT 35 (SCANCO Medical, Switzerland), and its sample size depended on its resolution; the maximum scan size encompassed a height of 120 mm and a diameter of 37.9 mm. The resolution varied from 3.5 to 72 μm. The MRI in this study was specifically developed for measurements at low temperatures with a static magnetic field intensity of 1.5 T produced by a permanent magnet of sintered NdFeB (Adachi and others, Reference Adachi, Yamaguchi, Ozeki and Kose2017, Reference Adachi, Yamaguchi, Ozeki and Kose2019). The primary component of the MRI system, including the permanent magnet, was located in a cold room. Generally, the static magnetic field of a permanent magnet is temperature dependent, which becomes nonuniform at low temperatures. This phenomenon causes distortion in the captured images. To avoid these effects, the measuring section containing the permanent magnet was kept strictly at 26 °C, where the static magnetic field uniformity area of the permanent magnet was optimized using heaters controlled by a thermostat. In contrast, the temperature of the area housing the measurement samples is maintained at the same temperature as that of the cold room, at approximately 0 ℃, through the circulation of air from the cold room (Adachi and others, Reference Adachi, Yamaguchi, Ozeki and Kose2017). The imaging space of the MRI was a 50 mm sphere, and the image resolution can range from 50 to 400 μm depending on the image time. In this study, we employed the spin echo (SE) imaging method, one of the predominant imaging methods in MRI studies (Bernstein and others, Reference Bernstein, King and Zhou2004), to analyze MRI images. Although SE imaging methods can display tissue anatomy with a high resolution, they require multiple pulses and echoes to generate a signal, resulting in relatively protracted imaging times.

2.2 Samples case and snow samples

To capture the same sample for X-ray CT and MRI, an identical sample case must be used to prevent sample breakage. However, a typical sample case for X-ray CT cannot be used for MRI imaging because certain parts consist of metal, which must not be used in MRI because of magnetism. Therefore, we developed a sample case comprised of acrylic, considering only its use within the strong magnetic field of the MRI (Fig. 1a). The case length for entering the sample was 75 mm, and the outer and inner diameters were 26 and 24 mm, respectively. Due to this sample case, the sample could be imaged using both MRI and X-ray CT. An additional feature of the sample case was that it had a pipe installed in its interior walls (Fig. 1b). The outer and inner diameters of the pipe were 3 and 1.8 mm, respectively. The pipe was used as a guide to introduce liquid into the sample and served as a landmark when superimposing X-ray CT and MRI images. The inner diameter of the pipe was insufficient to introduce the liquid directly due to interference from capillary forces. Therefore, we used a syringe equipped with a needle featuring an outer diameter of 1.27 mm and a length of 80 mm. For injecting the liquid into the snow sample, we installed the syringe needle in the pipe until its tip reached slightly above the bottom of the holder, and we then slowly injected the liquid (Fig. 1c). The amount of liquid to be injected varied depending on the sample. This was because the water head, which was target of our observation, required adjustment to align with the MRI field of view.

Figure 1. Images of the sample case. (a) Image of the sample case from the side. (b) Image of the sample case from above. (c) Schematic diagram illustrating the process of injecting liquid injection into a sample.

Snow samples were prepared using snow stored in a cold room (−15 ℃) for several months, and their grain size was controlled using sieves. Two snow samples were prepared: large grains (L-sample) and small grains (S-sample). The average grain size and bulk density of each snow sample were calculated from X-ray CT image analyses. In this study, the grain size was defined as the sphere-equivalent diameter obtained from the volume of each grain. The grain size and bulk density of the L-sample were 1.4 (SD = ± 0.7) mm and 409 kg m−3, whereas those of the S-sample were 1.2 (SD = ± 0.2) mm and 456 kg m−3, respectively.

2.3 Image procedures

The sample case was first filled with sieved snow in the cold room at −15 ℃, where the X-ray CT was located. The microstructure of the samples (snow grains and pore spaces) was imaged using the X-ray CT (Fig. 2a). X-ray CT images the sample at a higher resolution than MRI does, but the resolutions must be identical to superimpose the two images. Therefore, the image resolution of the X-ray CT and the MRI was fixed at 72 μm to align with the resolution of the MRI. The total imaging time of the sample using X-ray CT at this resolution was 2 h. This study used Otsu binarization (Otsu, Reference Otsu1979), a standard image analyses method, to binarize the X-ray CT images (snow grains and pore spaces).

Figure 2. Every image obtained during the imaging process. Red broken lines in the figures indicate the location of the pipe. (a) Images obtained using X-ray CT. White areas represent snow grains, and black areas indicate the pore spaces. (b) Images obtained using MRI. Blue areas indicate liquid (C12H26), and white areas indicate snow grains and pore spaces. (c) Image-superimposed MRI and X-ray CT images. White areas represent snow grains, black areas indicate the pore spaces, and blue areas indicate the liquid (C12H26). (d) Vertical cross section of the snow sample obtained from the reconstructed 3D image. Black areas indicate snow grains, white areas indicate the pore spaces, and blue areas indicate the liquid (C12H26).

After X-ray CT imaging, the sample case with the snow sample was moved to the cold room at −5 ℃, where the MRI was located. The snow case with the snow sample remained in the cold room until a constant sample temperature was reached under the cold room temperature (−5 ℃). As MRI imaging is time-consuming at the present stage with a resolution of 72 μm, n-Dodecane (C12H26) with a melting point of −9.7 ℃ was used instead of water to prevent the risk of snow metamorphism during the imaging. C12H24 was injected into the sample from the pipe using the syringe (Fig. 1c), and the C12H24 then permeated the sample owing to the capillary force of snow. An MRI image was subsequently captured, which provided C12H24 distribution information, under −5 ℃ (Fig. 2b). The total imaging duration of the sample using the MRI with a resolution of 72 μm was 8 h. Otsu binarization (Otsu, Reference Otsu1979) was also used to binarize each image in MRI images (C12H24 and others, including ice and pore space).

MRI and X-ray CT images at the same height (height resolution: 72 μm) were manually superimposed using ImageJ software (Collins, Reference Collins2007) based on the landmark of the pipe (Fig. 2c). Similar analyses were performed at each height, and the superimposed images were reconstructed to obtain 3D images to cross- and vertical-section images (Fig. 2d).

2.4 Difference in physical properties between water and C12h24

Differences in the physical properties of water and C12H24 likely affect their behavior in snow. The crucial physical properties to consider when assessing the movement of liquids in snow are density, surface tension, ice contact angle and the viscosity coefficient of each liquid. The first three (density, surface tension and ice contact angle) are related to capillary forces that determine the WRC, while the viscosity coefficient is related to the velocity of liquid movement. There are several density measurements available for C12H24 at positive temperature (see Appendix table 2). These results show the temperature-dependent nature of C12H24 density (Fig. 3a). Using its temperature dependency, we estimated the density of C12H24 at −5 ℃ to be 769 kg m−3, which is approximately 23% smaller than the density of water (1000 kg m−3). Measurements of the surface tension of C12H24 at positive temperatures were also reported (see Appendix table 3). These results show that the surface tension of C12H24 has a nearly constant value (0.02 N m−1) at the temperatures of 20 ℃–50 ℃. From these results, we estimated the surface tension of C12H24 at −5 ℃ to be 0.02 N m−1, which is approximately one-third that of the surface tension of water (0.07 N m−1). No studies have reported on the direct measurement of the contact angle of C12H24 on ice. Due to the lack of measured data, the contact angle of C12H24 with ice was assumed to be the same as that of water for simplicity in this study. However, this assumption should still be open to debate. Several studies have reported on viscosity coefficient measurements of C12H24 at positive temperatures (see Appendix Table 4). These results demonstrate the temperature-dependent nature of the viscosity coefficient of C12H24 (Fig. 3b). Using its temperature dependency, we estimated the viscosity coefficient of C12H24 at −5 ℃ to be approximately 2.0 × 103  Pa s, which is of a similar magnitude to that of water at 0 ℃ (1.7 × 103 Pa s).

Figure 3. Temperature-dependent nature of the physical properties of C12H24. (a) Temperature-dependent nature of the density of C12H24. Plotted data are shown in Appendix Table 2. The line in the figure is an approximate line represented by the formulas in the figure. (b) Temperature-dependent nature of the viscosity coefficient of C12H24. Plotted data are shown in Appendix Table 4. The curve in the figure is an approximate curve represented by the formulas in figure.

3. Results and discussion

3.1 Measurement error estimation

In this study, the same sample was analyzed using two images measured by entirely different methods: X-ray CT and MRI. Therefore, the size of snow grains and pore spaces may differ in each image due to differences in the measurement method. To investigate the error caused by this factor, we compared the total area of the pores measured via X-ray CT and that obtained through MRI at the same cross-sectional height. As already mentioned in the introduction, pores can be measured directly with X-ray CT but not with MRI. In this study, we selected several cross-sections near the bottom of the sample where the pores were nearly filled with C12H24. In calculating the total pore space using MRI, the space filled with C12H24 in each cross-section was considered as the total pore space. We analyzed 40 cross-sections and summarized the comparison results between X-ray CT images and MRI images (Fig. 4a). Essentially, the total pore area in each cross-section measured by both methods exhibited good agreement; however, in several cases, the total area of pores measured via X-ray CT appeared to surpass that obtained through MRI. This result indicates that the pore space determined through MRI may be underestimated. In fact, averaging over 40 cross sections, the pore space determined using the MRI images was 98 (SD = ± 3) % of the pore space determined using the X-ray images. One reason why the pore space determined using the MRI was smaller than that using X-ray CT can be attributed to the method employed for pore space estimation in this study. Filling all the pore spaces within a porous medium with liquid presents a challenge due to the entrapment of air within certain pores. In fact, field experiments conducted on soils have reported that several percentage points of the pores remained unfilled with water despite the apparent saturation of the soil (Kosugi and others, Reference Kosugi, Hopmans, Dane, Dane and Topp2002). Furthermore, water content measurements have reported that, despite the snow appearing saturated with water, a percentage points of the snow pore spaces are not filled with water. (e.g. Yamaguchi and others, Reference Yamaguchi, Katsushima, Sato and Kumakura2010). Therefore, it is possible that certain pores that did not contain C12H24 were not recognized as pores in the MRI image. Therefore, it is logical to conclude that the total pore space calculated using MRI images was slightly smaller than that using X-ray CT images. On the other hand, in ten cross sections, the total pore space calculated using MRI image was slightly larger than the that using X-ray CT images. This may be due to the effect of a slight change in pore distribution during the transfer of the sample cases from X-ray CT to MRI, but the difference is only 2% of the total pore area for each cross-section. Based on these reasons, we concluded that the effects of different measurement methods on the error do not have a significant impact on the analyses.

Figure 4. Analysis of the effects of discrepancies between X-ray CT and MRI images. (a) Comparison results of pore spaces between images of X-ray CT and MRI images. Dashed lines show the 1:1 line. (b) Schematic diagram of the method for analyzing image mismatches between X-ray CT and MRI images. White areas are snow grain shapes determined through MRI, while the areas surrounded by orange lines are snow grain shapes determined using X-ray CT. Red arrows show examples of areas where images are mismatched.

The originality of our method lies in the superimposition of MRI and X-ray CT images. During image superimposition, we manually adjusted both images based on the position of the pipe. However, if the grains are not perfectly aligned with each other, the distribution of liquid-filled pores may be misaligned, which could affect the measurement results. In addition, when moving the sample case from X-ray CT to MRI, the grains in the case could slightly move, which could affect the imaging results. To investigate the measurement error resulting from these factors, we compared the shape of individual snow grains determined using X-ray CT with those determined using MRI in 10 cross-sectional areas where it was presumed that the pore space had been saturated with C12H24. Figure 4b shows an example of the comparison of snow grain shapes using X-ray CT and those using MRI. In the figure, white areas represent snow grain shapes determined by MRI, while the areas surrounded by orange lines represent snow grain shapes determined by X-ray CT. As MRI cannot directly image snow grains, the white areas of each grain were estimated from spaces not filled with C12H24. Therefore, air-filled pores surrounding the grains may also be included in the white shape. To evaluate the effect of position mismatching, the positions of snow grains determined via X-ray CT were used as a reference. If the snow grain position was matched perfectly between the X-ray CT and MRI images, the areas surrounded by orange lines would be white. In practice, black areas are discernible within the areas enclosed by the orange line, as indicated by the red arrows in Figure 4b. This indicates that areas that should be determined as snow grain areas in MRI images are instead determined as pores due to reasons such as the misalignment of the grain. Therefore, the unmatched ratio was calculated as the ratio of black areas in the area surrounded by orange lines. We investigated the unmatched ratio for grains in the ten cross sectional areas; on average, the unmatched area accounted for 17 (SD ± 15) % of the area across the grains in these ten cross sections. The current unmatched ratio may prove too substantial to overlook in the context of a detailed analysis. Therefore, there is potential for improvement in the matching of X-ray CT and MRI images. Specifically, it is necessary to develop algorithms that automatically perform positioning using image processing technology rather than performing positioning manually.

3.2 Visualization of liquid distribution within the microstructure of snow

Figure 5 shows the cross sectional views of the L-sample. Each cross-sectional view was obtained at a different height from the bottom of the sample (Fig. 6). The white, black and blue areas in the figures indicate snow grains, pore spaces and liquid (C12H24), respectively. Very few black areas are in the cross section near the bottom (height: 3.24 mm) (Fig. 5a). This indicates that the pore spaces were nearly entirely filled with liquid. In the cross sectional views, up to a certain height (Fig. 5a, b, c), the pore spaces surrounding the snow grains increased, but most of the pore space remained filled with liquids. As C12H24 was injected directly into the sample case in this study, defining a free water surface was impossible. Therefore, in a strict sense, the data obtained in this study cannot be called a WRC. However, this area may be considered equivalent to the air entry suction area identified in the WRC of the wetting process (boundary wetting curve). The black area rapidly increased because the liquid could not penetrate the large pore spaces (Fig. 5d, e, f). This trend indicates that smaller pore spaces exhibit greater capillary forces. Only small pore spaces between snow grains indicated the presence of liquid (Fig. 5g), and ultimately, all pore spaces were devoid of liquid (Fig. 5h).

Figure 5. Cross sectional views of the L-sample. White areas represent snow grains, black areas indicate the pore spaces and blue areas indicate the liquid (C12H26). (a) Height is 3.24 mm. (b) Height is 8.28 mm. (c) Height is 14.18 mm. (d) Height is 15.48 mm. (e) Height is 16.20 mm. (f) Height is 16.92 mm. (g) Height is 17.64 mm. (h) Height is 20.45 mm.

Figure 6. Vertical section views of the L-sample (distance of 12.53 mm). Distance is from the left side of the cross-sectional view. The left axis shows the height position of the cross sections in Figure 5.

Figure 6 shows the vertical cross-sectional view of the L-sample. In the lower-height region, as shown in the cross sectional view (Fig 5a, b, and c), small pore spaces were observed surrounding certain snow grains; however, the pore spaces were nearly entirely filled with liquid. From the vertical cross sections, the liquid in the snow was essentially connected from the bottom to the top, although some connections twisted and turned because of the influence of snow grains and capillary forces. The upper level of the liquid height (hydraulic head) was not constant across all vertical cross-sections. This can be attributed to the nonuniformity of the pore space. The cross sectional view (Fig. 5) reveals various pore space sizes at the same height. These results demonstrate the significance of the influence of snow microstructure inhomogeneities on the behavior of liquids in snow.

3.3 Analyses of the relationship between size distribution of pore space and liquid distribution

We investigated the influence of pore space distribution on liquid behavior in snow (Figs. 5, and 6). The shapes of the pore spaces were highly complex, with the pore spaces in contact and connected to each other (Figs. 5 and 6). They were developed in 3D. Therefore, segmenting each individual pore space was necessary. In this study, we adopted 3D watershed plugins in Classic Watershed of ImageJ/Fiji to determine the boundaries between the pore spaces. The concept of a Classic Watershed in the ImageJ/Fiji plugin is to perform watershed segmentation of grayscale 2D/3D images using the flood simulation described by Soille and Vincent (Reference Soille and Vincent1990). Figure 7 shows an example of pore space analysis using the 3D watershed scheme. First, the 3D distribution of the pore space was reconstructed based on the X-ray images (Fig. 7a), and each pore space was then segmented using a 3D watershed scheme (Fig. 7b). Figure 7b suggests that the shape of the pore space segmented by the 3D watershed scheme is not simple, but exhibits various complex shapes. Therefore, the pore space segmented using the 3D watershed scheme was considered to be more natural than considering pores as simple tubes. Based on the determination of each pore space shape, the pore space in each X-ray CT cross-sectional image was separated (Fig. 8a). The MRI images were then superimposed on the X-ray images (Fig. 8b), as described in Section 2.3. Using the images in Figure 8a and b, the distribution of pore space areas and the ratio occupied by liquid for each pore space in each cross section were calculated. The walls of the sample case may have affected the behavior of the liquid in the sample. To avoid these influences, we only analyzed data in the center area of the sample with 11.52 × 11.52 mm (160 × 160 pixels). In the analysis, only pores with size (>0.003 mm2) were used in order to avoid the effects of image mismatch discussed in Section 3.1.

Figure 7. Example of pore space analyses using a 3D watershed scheme. (a) 3D image of the reconstructed pore space based on X-ray CT images. (b) 3D image of segmented pore spaces with a 3D watershed scheme. Each color represents an individual pore space.

Figure 8. Images used in the analyses. (a) Image of the segmented pore spaces. Black areas indicate snow grains, and white areas indicate the pore spaces. The black lines in the figure indicate the boundaries between the pore spaces determined by the 3D watershed. (b) Superimposed MRI and segmented pore-space images. Black areas indicate snow grains, white areas indicate the pore spaces, and gray areas indicate liquids.

Figures 9a and 9d show the analysis results, including that the characteristics of the pore space distribution averaged over the entire cross section differed between the L-sample and S-sample. The L-sample exhibited a moderate peak, and the pore spaces were distributed over a wide range (Fig. 9a), whereas the S-sample exhibited a sharp peak, and the pore spaces were concentrated in a narrow range (Fig. 9d). The grain size of the L-sample was larger than that of the S-sample while the density of the S-sample was higher than that of the L-sample. Yamaguchi and others (Reference Yamaguchi, Watanabe, Katsushima, Sato and Kumakura2012) indicated that the smaller grain size, the more uniform the pore size if they have similar density, and larger the density, the more uniform the pore size if they have an identical grain size. Therefore, the small grain size and high density contributed to the sharp peak in the pore space, as in the S-sample. In addition, the larger SD of grain size in the L-sample also affects the larger spread of pore space area. Considering the liquid occupancy according to the size of each pore space, the smaller the pore space, the higher the degree of liquid occupation up to a certain height range (Fig. 9b and 9e). However, above a certain height, the liquid occupancy decreased sharply from the pore spaces with a larger area. Figures 9c and 9f show the ratio of the pore space occupied by the liquid to the total pore space at each height, and their trend can be considered similar to the trend in the volumetric liquid content. As previously mentioned, the data obtained in this study is not a true WRC of the wetting process (boundary wetting curve) because the free water surface could not be determined. However, the trends in Figure 9c and 9f are similar to the measured WRC (boundary wetting curve) of snow using water (Adachi and others, Reference Adachi, Yamaguchi, Ozeki and Kose2020); that is, the nearly constant value areas are maintained at a certain height, and their values subsequently rapidly decrease with height above a certain point.

Figure 9. Analyses results. (a and d) Distribution of the area size of each pore space. The x-axis represents the pore space area, and the y-axis represents the ratio of the number of pore-space sizes divided into each class to the total number. a shows data of L-sample and d shows data of S-sample. (b and e) Distribution of the ratio of occupied pore space size by liquid divided into each class by its total number. The x-axis represents the pore space, and the y-axis represents the height of the cross-section from the bottom of the sample case (height resolution is 0.072 mm). The ratio of the pore space size of the liquid divided into each class to its total number is shown in the blue scale in the legend. b shows data of L-sample and e shows data of S-sample. (c and f) Ratio of pore spaces occupied by liquid to the total area. The x-axis is the ratio of the pore spaces occupied by liquid to the total area, and the y-axis is the height of the cross-section from the bottom of the sample case (height resolution is 0.072 mm). c shows data of L-sample and f shows data of S-sample.

3.4 Differences between WRCs of water and C12h24

As shown in Section 2.4, there are differences between the physical properties of C12H24 and water. We qualitatively investigated the influence of these differences on the behavior of the WRC. Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020) examined the boundary wetting curve of snow (the grain size was 1.2 mm and the density was 492 kg m−3), similar to the snow sample called the S-sample in this study. Figure 10 shows the comparison results between the results of Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020) and the S-sample. To obtain the WRC of the S-sample, we estimated the liquid content using the porosity calculated from density and the ratio of the pore space occupied by the liquid to the total pore space at each height in Figure 9f. In the figure, we also fitted all data with the van Genuchten model (van Genuchten, Reference van Genuchten1980) using the Retention Curve (RETC) software (van Genuchten and others, Reference van Genuchten, Simunek, Leij and Sejna1994). The VG model is as follows:

(1)$$S_e = \displaystyle{{\theta -\theta _r} \over {\theta _{s-\theta _r}}} = ( {1 + {\lfloor{\alpha h} \rfloor }^n} ) ^{{-}m}$$

where Se is the effective water content, θ is the volumetric water content, θr and θs are the residual and saturated volumetric water contents, respectively, and h is the suction. α, n and m are parameters that affect the shape of the WRC. In this study, we assumed that m = 1–1/n as referred to by Yamaguchi and others (Reference Yamaguchi, Katsushima, Sato and Kumakura2010, Reference Yamaguchi, Watanabe, Katsushima, Sato and Kumakura2012). As already mentioned, it is not possible to determine the free water surface in this experiment. Therefore, the free water surface was defined as the bottom of the sample case for simplicity of the analysis. Figure 10 indicates large differences in the WRC behavior between water and C12H24: The height of air entry suction of C12H24 is substantially smaller than that of water, and the change ratio of θ with the h of C12H24 is substantially larger than that of water.

Figure 10. Comparison of the WRC between the data of Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020) and the S-sample. The blue circles are data from the S sample, and the black triangles are data from Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020). Blue and black broken lines are the fitting curves of the VG model with each parameter in Table 1.

Table 1. Values of α and n in the VG model in Figure 10

To investigate the cause of the difference between the WRCs of water and C12H24, we focused on the difference in h, which is related to the behavior of the WRC. h is described by the Laplace equation as follows:

(2)$$h = {-}\displaystyle{{2\gamma \ \cos \beta } \over {\rho gr}}$$

where, r is the capillary tube radius, ρ is the density, γ is the surface tension, and β is the contact angle between liquid and ice particles. The values of the h of water and the suction of C12H24 are denoted by hw and hc, respectively. Assuming that the contact angles of water and C12H24 are identical, the ratio (Rh) of hc to hw (hc/hw) is shown as follows based on Eqn (2):

(3)$$R_h = \displaystyle{{h_c} \over {h_w}} = \displaystyle{{\gamma _c} \over {\gamma _w}} \times \displaystyle{{\rho _w} \over {\rho _c}} $$

where the subscript c indicates the value of the C12H24, and the subscript w indicates the value of the water. The calculated value of Rh was 0.36, which shows that the h of C12H24 was only 0.36-fold stronger than that of water under the same r. Table 1 lists the obtained values of α and n in the VG model for data of Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020) and the S-sample used in this study. The values of α by Adachi and others (Reference Adachi, Yamaguchi, Ozeki and Kose2020) and the S-sample are shown as αw and αc, respectively. The ratio (Rα) of αc to αw (αc/αw) was calculated to be 2.6, a value of the same magnitude as the inverse of Rh (2.8). Generally, α in the VG model is related to the inverse of the air entry suction. Thus, our result, that the difference in α values between water and C12H24 can be explained by the difference in the strength of h, is logical. But the influence of the contact angle of Rh is particularly significant. In this analysis, the contact angle of C12H24 with ice was assumed to be the same as water, but the contact angle of C12H24 with ice should be properly measured for quantitative discussion. Conversely, for n, which is related to the slope of θ vs h in the VG model, we fail to explain why the value of n was different for water and C12H24. Therefore, to convert the WRC of C12H24 to that of water, additional experiments are required to quantitatively explain the difference in n between C12H24 and water.

4. Possibility of imaging with water based on this method

As this study aimed to establish a method for superimposing X-ray CT and MRI, C12H24 was utilized instead of water as the liquid to avoid affecting the snow metamorphism. In contrast, as shown in Section 3.4, the results of this study may not be directly applicable to the behavior of water in snow. Therefore, to achieve the final objective of this study, namely, to understand the influence of snow microstructure on the behavior of water in snow, there are two approaches: The first is to understand how the different physical properties of water and C12H24 affect the behavior of liquids in snow; based on this knowledge, we continue to use C12H24 instead of using water. The second is the use of water as a liquid. Hereafter, we discuss the possibility of using water in our system.

When water is used, it is essential that the sample environment is stabilized at 0 °C during the imaging time. To maintain a stable temperature of 0 °C, we are currently developing a new sample case that will enable conventional sample cases to be placed inside a larger sample case to provide additional space between walls. By filling the wall-to-wall space with ice and water, it is anticipated that a temperature of 0 °C can be maintained throughout the duration of image times (Fig. 11). MRI imaging time with C12H24 required 8 h for the resolution used in this study, and a similar or even longer imaging time would be required if water was used instead of C12H24. Therefore, snow metamorphosis caused by extended MRI imaging time is expected to be a major issue with the current method, even if the temperature is kept at 0 °C.

Figure 11. Image and schematic diagram of the new sample case that we are developing. Case 2 is the same sample case shown in Figure 1 and case 2 is one size larger than case 1.

There are two possible approaches to shorten the MRI imaging time. The first is to decrease the longitudinal relaxation time (T1). T1 is the time required for a substance to return from its excited state to its original state. Therefore, the longer the T1, the longer the imaging time (Bernstein and others, Reference Bernstein, King and Zhou2004). T1 for pure water was approximately 1200 ms (the T1 of C12H24 was approximately 600 ms) under the condition used in this study (1.5 T, 0℃). Therefore, to obtain sufficient proton density-weighted images with the SE method used for MRI imaging, several hours of imaging time were required with the same resolution used in this study. One possible approach to shorten the T1 is to use a low-concentration (5 mmol/L) aqueous copper sulfate (CuSO4) solution (Katsushima and others, Reference Katsushima, Adachi, Yamaguchi, Ozeki and Kumakura2020). This shortens T1 by approximately 100 ms, which is 1/12 that of pure water. Therefore, the imaging time will become 1/12 of the imaging time required when using pure water. It is assumed that the presence of low concentrations of copper sulfate does not significantly affect the behavior of water in snow; however, this effect may need to be considered when the data are analyzed in detail.

The second method involves adopting a slightly coarser image resolution in MRI compared to that utilized in X-ray CT. Currently, the resolution of X-rays and MRI is unified at 72 μm; if the imaging resolution of MRI is doubled to 144 μm, the imaging time can be decreased by 1/4 of its current duration. In this case, however, the question remains whether two images with different imaging resolutions can be adequately superimposed and whether the relationship between pore spaces and the presence of water can be sufficiently analyzed.

These two methods have their advantages and disadvantages, and certain issues must be resolved. To achieve our ultimate goal of understanding the influence of snow microstructure on the behavior of water in snow, we are studying the above two methods and combining them appropriately to decrease the time required for imaging, which can avoid snow metamorphism.

5. Conclusions

We established a novel method to visualize the liquid distribution in snow by superimposing MRI and X-ray CT images. X-ray CT can visualize the microstructure of snow but cannot discriminate water in snow. In contrast, MRI can visualize water in snow but cannot discriminate snow microstructures, such as snow grains and pore spaces. Therefore, our innovative method successfully combines the advantages of X-ray CT and MRI. Using our method, the relationships between the microstructure of snow and the liquid (C12H24) distribution in snow were visualized. For example, it is possible to analyze information on the spatial distribution of pore spaces and to determine the extent to which liquid occupies pore spaces of varying sizes in a 3D context.

Although we have established a novel method, there remains potential for improvement in experiments using water as the liquid instead of C12H24. Specifically, the MRI imaging time should be decreased such that the snow does not metamorphose during the imaging. To solve this problem, we are currently researching several solutions, including decreasing the longitudinal relaxation time using a copper sulfate solution and decreasing the imaging time by increasing the resolution roughness. Through these studies, we hope to establish a method to clarify the relationship between the snow microstructure and water behavior in snow, and to better understand heterogeneous water movement in snow.

Acknowledgements

We gratefully acknowledge the comments by the members of the Snow and Ice Research Center, National Research Institute for Earth Science and Disaster Resilience. We greatly appreciate the helpful comments and suggestions from Scientific Editor N. Helbig of WSL Institute for Snow and Avalanche Research SLF, reviewer M. Lombardo of WSL Institute for Snow and Avalanche Research SLF, and an anonymous reviewer. This study was part of the project ‘Research on combining risk monitoring and forecasting technologies for mitigation of diversifying snow disasters’. This study was also supported by JSPS KAKENHI, Grant Numbers JP21H04601 (HaMaNAS PJ).

Appendix

Table 2. Data for measured density of C12H24

Table 3. Data for measured surface tension of C12H24

Table 4. Data for measured viscosity coefficient of C12H24

References

Adachi, S and 6 others (2009) Development of a compact magnetic resonance imaging system for a cold room. Review of Scientific Instruments 80, 054701. doi: 10.1063/1.3129362CrossRefGoogle ScholarPubMed
Adachi, S, Yamaguchi, S, Ozeki, T and Kose, K (2017) Current status of application of cryospheric MRI to wet snow studies (in Japanese with English abstract). Journal of the Japanese Society of Snow and Ice 79, 497509.CrossRefGoogle Scholar
Adachi, S, Yamaguchi, S, Ozeki, T and Kose, K (2019) Development of a magnetic resonance imaging system for wet snow samples. Bulletin of Glaciological Research 37S, 4351. doi: 10.5331/bgr.17SR01CrossRefGoogle Scholar
Adachi, S, Yamaguchi, S, Ozeki, T and Kose, K (2020) Application of a magnetic resonance imaging method for nondestructive, three-dimensional, high-resolution measurement of the water content of wet snow samples. Frontiers in Earth Science 8. doi: 10.3389/feart.2020.00179CrossRefGoogle Scholar
Avanzi, F, Hirashima, H, Yamaguchi, S, Katsushima, T and Michele, CD (2016) Observations of capillary barriers and preferential flow in layered snow during cold laboratory experiments. The Cryosphere 10, 20132026. doi: 10.5194/tc-10-2013-2016CrossRefGoogle Scholar
Azizian, S and Bashavard, N (2008) Surface tension of dilute solutions of alkanes in cyclohexanol at different temperatures. Journal of Chemical and Engineering Data 53(10), 24222425. doi: 10.1021/je8004112CrossRefGoogle Scholar
Baggi, S and Schweizer, J (2008) Characteristics of wet-snow avalanche activity: 20 years of observations from a high alpine valley (Dischma, Switzerland). Natural Hazards 50, 97108. doi: 10.1007/s11069-008-9322-7CrossRefGoogle Scholar
Bernstein, M, King, K and Zhou, X (2004) Handbook of MRI Pulse Sequence, 1st Edn. New York: Academic Press, pp. 1040.Google Scholar
Blahušiak, M and Schlosser, Š (2014) Physical properties of phosphonium ionic liquid and its mixtures with dodecane and water. Journal of Chemical Thermodynamics 72, 5464. doi: 10.1016/j.jct.2013.12.022CrossRefGoogle Scholar
Calonne, N and 6 others (2012) 3-D image-based numerical computations of snow permeability: links to specific surface area, density, and microstructural anisotropy. The Cryosphere 6, 939951. doi: 10.5194/tc-6-939-2012CrossRefGoogle Scholar
Coleou, C, Lesaffre, B, Brzoska, J, Ludwig, W and Boller, E (2003) Three-dimensional snow images by X-ray microtomography. Annals of Glaciology 32, 7581. doi: 10.3189/172756401781819418CrossRefGoogle Scholar
Collins, TJ (2007) ImageJ for microscopy. Bio Techniques 43, 2530.Google ScholarPubMed
Dietz, AJ, Kuenzer, C, Gessner, U and Dech, S (2012) Remote sensing of snow: a review of available methods. International Journal of Remote Sensing 33, 40944134. doi: 10.1080/01431161.2011.640964CrossRefGoogle Scholar
Donahue, C, Skiles, SMK and Hammonds, K (2022) Mapping liquid water content in snow at the millimeter scale: an intercomparison of mixed-phase optical property models using hyperspectral imaging and in situ measurements. The Cryosphere 16, 4359. doi: 10.5194/tc-16-43-2022CrossRefGoogle Scholar
González, B, Domínguez, A and Tojo, J (2003) Dynamic viscosities of 2-butanol with alkanes (C8, C10, and C12) at several temperatures. Journal of Chemical Thermodynamics 36(4), 267275. doi: 10.1016/j.jct.2003.12.005CrossRefGoogle Scholar
González, B, Dominguez, A, Tojo, J and Cores, R (2004) Dynamic viscosities of 2-pentanol with alkanes (octane, decane, and dodecane) at three temperatures T=(293.15, 298.15, and 303.15) K. New UNIFAC−VISCO interaction parameters. Journal of Chemical and Engineering Data 49(5), 12251230. doi: 10.1021/je034208mCrossRefGoogle Scholar
Hagenmuller, P, Chambon, G, Lesaffre, B, Flin, F and Naaim, M (2013) Energy-based binary segmentation of snow microtomographic images. Journal of Glaciology 59, 859873. doi: 10.3189/2013JoG13J035CrossRefGoogle Scholar
Heggli, M and 7 others (2011) Measuring snow in 3-D using X-ray tomography: assessment of visualization techniques. Annals of Glaciology 52(58), 231236. doi: 10.3189/172756411797252202CrossRefGoogle Scholar
Hirashima, H, Yamaguchi, S, Sato, A and Lehning, M (2010) Numerical modeling of liquid water movement through layered snow based on new measurements of the water retention curve. Cold Regions Science and Technology 64(2), 94103. doi: 10.1016/j.coldregions.2010.09.003CrossRefGoogle Scholar
Hirashima, H, Yamaguchi, S and Katsushima, T (2014) A multi-dimensional water transport model to reproduce preferential flow in the snowpack. Cold Regions Science and Technology 108, 8090. doi: 10.1016/j.coldregions.2014.09.004CrossRefGoogle Scholar
Kaempfer, UT and Schneebeli, M (2007) Observation of isothermal metamorphism of new snow and interpretation as a sintering process. Journal of Geophysical Research 112, D24101. doi: 10.1029/2007JD009047CrossRefGoogle Scholar
Katsushima, T, Adachi, S, Yamaguchi, S, Ozeki, T and Kumakura, T (2020) Nondestructive three-dimensional observations of flow finger and lateral flow development in dry snow using magnetic resonance imaging. Cold Regions Science and Technology 170, 102956. doi: 10.1016/j.coldregions.2019.102956CrossRefGoogle Scholar
Khire, MV, Benson, C and Bosscher, PJ (2000) Capillary barriers: design variables and water balance. Journal of Geotechnical and Geoenvironmental Engineering 126, 695708. doi: 10.1061/(ASCE)1090-0241(2000)126:8(695)CrossRefGoogle Scholar
Klute, A (1986) Water retention: laboratory methods. In Klute, A (ed.), Methods of Soil Analysis, Part 1, Physical and Mineralogical Methods. Madison: ASA and SSSA, pp. 635662, doi: 10.2136/sssabookser5.1.2ed.c26CrossRefGoogle Scholar
Koller, MT and 7 others (2017) Liquid viscosity and surface tension of n-Dodecane, n-Octacosane, their mixtures, and a wax between 323 and 573K by surface light scattering. Journal of Chemical and Engineering Data 62(10), 33193333. doi: 10.1021/acs.jced.7b00363CrossRefGoogle Scholar
Kosugi, I, Hopmans, WJ and Dane, HJ (2002) Parametric models. In Dane, JH and Topp, GC (eds), Methods of Soil Analyses. Part 4. Physical Methods. Madison, WI: Socience Society of America, Inc., pp. 1692.Google Scholar
Löwe, H, Spiegel, KJ and Schneebeli, M (2011) Interfacial and structural relaxations of snow under isothermal conditions. Journal of Glaciology 57(203), 499510. doi: 10.3189/002214311796905569CrossRefGoogle Scholar
Maggiore, E, Tommasini, M and Ossi, PM (2022) Raman spectroscopy-based assessment of the liquid water content in snow. Molecules 27, 626. doi: 10.3390/molecules27030626CrossRefGoogle ScholarPubMed
Marsh, P and Woo, MK (1984) Wetting front advance and freezing of meltwater within a snow cover 1. Observations in the Canadian Arctic. Water Resources Research 20, 18531864. doi: 10.1029/WR020i012p01853CrossRefGoogle Scholar
Marsh, P and Woo, MK (1985) Meltwater movement in natural heterogeneous snow covers. Water Resources Research 21, 17101716, doi:10.1029/WR021i011p01710CrossRefGoogle Scholar
Marshall, HP, Conway, H and Rasmussen, LA (1999) Snow densification during rain. Cold Regions Science and Technology 30, 3541. doi: 10.1016/S0165-232X(99)00011-7CrossRefGoogle Scholar
Mejía, A, Cartes, M and Segura, H (2011) Interfacial tensions of binary mixtures of ethanol with octane, decane, dodecane, and tetradecane. Journal of Chemical Thermodynamics 43(9), 13951400. doi: 10.1016/j.jct.2011.04.005CrossRefGoogle Scholar
Mitterer, C and Schweizer, J (2013) Analysis of the snow-atmosphere energy balance during wet-snow instabilities and implications for avalanche prediction. The Cryosphere 7, 205216. doi: 10.5194/tc-7-205-2013CrossRefGoogle Scholar
Mitterer, C, Hirashima, H and Schweizer, J (2011) Wet-snow instabilities: comparison of measured and modelled liquid water content and snow stratigraphy. Annals of Glaciology 52, 201208. doi: 10.3189/172756411797252077CrossRefGoogle Scholar
Nomura, M (1994) Studies on the delay mechanism of runoff to snowmelt. Contributions from the Institute of Low Temperature Science 39, 149. Available at http://hdl.handle.net/2115/28394Google Scholar
Oliveira, HL, Silva, LJ and Aznar, M Jr. (2011). Apparent and partial molar volumes at infinite dilution and solid–liquid equilibria of dibenzothiophene+alkane systems. Journal of Chemical and Engineering Data 56(11), 39553962, doi: 10.1021/je200327sCrossRefGoogle Scholar
Otsu, N (1979) A threshold selection method from gray-level histograms. IEEE Transactions on Systems, Man and Cybernetics 9(1), 6266. doi: 10.1109/TSMC.1979.4310076CrossRefGoogle Scholar
Pinzer, BR, Schneebeli, M and Kaempfer, UT (2012) Vapor flux and recrystallization during dry snow metamorphism under a steady temperature gradient as observed by time-lapse micro-tomography. The Cryosphere 6, 11411155. doi: 10.5194/tc-6-1141-2012CrossRefGoogle Scholar
Prak, JLD, Alexandre, MS, Cowart, SJ and Trulove, CP (2014) Density, viscosity, speed of sound, bulk modulus, surface tension, and flash point of binary mixtures of n-Dodecane with 2,2,4,6,6-Pentamethylheptane or 2,2,4,4,6,8,8-Heptamethylnonane. Journal of Chemical and Engineering Data 59(4), 13341346.CrossRefGoogle Scholar
Prak, JLD, Mungan, LA, Cowart, SJ and Trulove, CP (2018) Densities, viscosities, speeds of sound, bulk moduli, surface tensions, and flash points of binary mixtures of ethylcyclohexane or methylcyclohexane with n-dodecane or n-hexadecane at 0.1 MPa. Journal of Chemical and Engineering Data 63(5), 16421656. doi: 10.1021/acs.jced.8b00008CrossRefGoogle Scholar
Prak, JLD, Morrow, HB, Cowart, SJ, Trulove, CP and Harrison, AJ (2019) Thermophysical properties of binary mixtures of n-Dodecane with n-Alkylcyclohexanes: experimental measurements and molecular dynamics simulations. Journal of Chemical and Engineering Data 64(4), 15501568. doi: 10.1021/acs.jced.8b01135CrossRefGoogle Scholar
Rivas, AM, Pereira, MS, Banerji, N and Iglesias, PT (2004) Permittivity and density of binary systems of {dimethyl or diethyl carbonate}+n-dodecane from T=(288.15 to 328.15) K. Journal of Chemical Thermodynamics 36(3), 183191. doi: 10.1016/j.jct.2003.11.007CrossRefGoogle Scholar
Schmid, L and 6 others (2015) A novel sensor combination (upGPR-GPS) to continuously and nondestructively derive snow cover properties. Geophysical Research Letters 42, 33973405. doi: 10.1002/2015GL063732CrossRefGoogle Scholar
Schneebeli, M (2004) Numerical simulation of elastic stress in the microstructure of snow. Annals of Glaciology 38, 339342.CrossRefGoogle Scholar
Shimizu, H (1970) Air permeability of deposited snow. Contributions from the Institute of Low Temperature Science A22, 32pp.Google Scholar
Soille, P and Vincent, ML (1990) Determining watersheds in digital picture via flooding simulations. Proc. SPIE 1360, Visual Communications and Image Processing '90: Fifth in a Series, doi:10.1117/12.24211CrossRefGoogle Scholar
Techel, F and Pielmeier, C (2011) Point observations of liquid water content in wet snow -investigating methodical, spatial and temporal aspects. The Cryosphere 5, 405418. doi: 10.5194/tc-5-405-2011CrossRefGoogle Scholar
Tian, Q and Liu, H (2007) Densities and viscosities of binary mixtures of tributyl phosphate with hexane and dodecane from (298.15 to 328.15) K. Journal of Chemical and Engineering Data 52(3), 892897. doi: 10.1021/je060491oCrossRefGoogle Scholar
van Genuchten, MT (1980) A closed-form equation for predicting the hydraulic conductivity of unsaturated soils. Soil Science Society of America Journal 44, 892989.CrossRefGoogle Scholar
van Genuchten, MTh, Simunek, J, Leij, FJ and Sejna, M (1994). The RETC code for quantifying the hydraulic functions of unsaturated soils. Technical Report EPA / 600/ 2-91/065, U.S. Environmental Protection Agency, pp10.Google Scholar
Waldner, PA, Schneebeli, M, Schultze-Zimmermann, U and Flühler, H (2004) Effect of snow structure on water flow and solute transport. Hydrological Processes 18, 12711290. doi: 10.1002/hyp.1401CrossRefGoogle Scholar
Walter, B, Horender, S, Gromke, C and Lehning, M (2013) Measurements of the pore-scale water flow through snow using fluorescent particle tracking velocimetry. Water Resources Research 49, 74487456. doi: 10.1002/2013WR013960CrossRefGoogle Scholar
Wever, N, Fierz, C, Mitterer, C, Hirashima, H and Lehning, M (2014) Solving Richards equation for snow improves snowpack meltwater runoff estimations in detailed multi-layer snowpack model. The Cryosphere 8, 257274. doi: 10.5194/tc-8-257-2014CrossRefGoogle Scholar
Wever, N and 5 others (2015) Verification of the multi-layer SNOWPACK model with different water transport schemes. The Cryosphere 9, 26552707. doi: 10.5194/tcd-9-2655-2015CrossRefGoogle Scholar
Wiese, M and Shneebeli, M (2017) Snowbreeder 5: a micro-CT device for measuring the snow microstructure evolution under the simultaneous influence of a temperature gradient and compaction. Journal of Glaciology 63, 355360. doi: 10.1017/jog.2016.143CrossRefGoogle Scholar
Yamaguchi, S, Katsushima, T, Sato, A and Kumakura, T (2010) Water retention curve of snow with different grain sizes. Cold Regions Science and Technology 64, 8793. doi: 10.1016/j.coldregions.2010.05.008CrossRefGoogle Scholar
Yamaguchi, S, Watanabe, K, Katsushima, T, Sato, A and Kumakura, T (2012) Dependence of the water retention curve of snow on snow characteristics. Annals of Glaciology 53, 612. doi: 10.3189/2012AoG61A001CrossRefGoogle Scholar
Yamaguchi, S, Hirashima, H and Ishii, Y (2018) Year-to-year changes in preferential flow development in a seasonal snowpack and their dependence on snowpack conditions. Cold Regions Science and Technology 149, 95105. doi: 10.1016/j.coldregions.2018.02.009CrossRefGoogle Scholar
Yang, Z, Bi, Q and Feng, S (2016) Viscosity measurement of endothermic fuels at temperatures from 303 K to 673 K and pressures up to 5.00 MPa. Journal of Chemical and Engineering Data 61(10), 34723480. doi: 10.1021/acs.jced.6b00391CrossRefGoogle Scholar
Zhang, L, Guo, Y, Xiao, J, Gong, X and Fang, W (2011) Density, refractive index, viscosity, and surface tension of binary mixtures of exo-Tetrahydrodicyclopentadiene with some n-Alkanes from (293.15 to 313.15) K. Journal of Chemical and Engineering Data 58(11), 42684273. doi: 10.1021/je200757aCrossRefGoogle Scholar
Zhao, G, Yuan, Z, Yin, J and Ma, S (2019) Thermophysical properties of fatty acid methyl and ethyl esters. The Journal of Chemical Thermodynamics 134, 195212. doi: 10.1016/j.jct.2019.02.025CrossRefGoogle Scholar
Figure 0

Figure 1. Images of the sample case. (a) Image of the sample case from the side. (b) Image of the sample case from above. (c) Schematic diagram illustrating the process of injecting liquid injection into a sample.

Figure 1

Figure 2. Every image obtained during the imaging process. Red broken lines in the figures indicate the location of the pipe. (a) Images obtained using X-ray CT. White areas represent snow grains, and black areas indicate the pore spaces. (b) Images obtained using MRI. Blue areas indicate liquid (C12H26), and white areas indicate snow grains and pore spaces. (c) Image-superimposed MRI and X-ray CT images. White areas represent snow grains, black areas indicate the pore spaces, and blue areas indicate the liquid (C12H26). (d) Vertical cross section of the snow sample obtained from the reconstructed 3D image. Black areas indicate snow grains, white areas indicate the pore spaces, and blue areas indicate the liquid (C12H26).

Figure 2

Figure 3. Temperature-dependent nature of the physical properties of C12H24. (a) Temperature-dependent nature of the density of C12H24. Plotted data are shown in Appendix Table 2. The line in the figure is an approximate line represented by the formulas in the figure. (b) Temperature-dependent nature of the viscosity coefficient of C12H24. Plotted data are shown in Appendix Table 4. The curve in the figure is an approximate curve represented by the formulas in figure.

Figure 3

Figure 4. Analysis of the effects of discrepancies between X-ray CT and MRI images. (a) Comparison results of pore spaces between images of X-ray CT and MRI images. Dashed lines show the 1:1 line. (b) Schematic diagram of the method for analyzing image mismatches between X-ray CT and MRI images. White areas are snow grain shapes determined through MRI, while the areas surrounded by orange lines are snow grain shapes determined using X-ray CT. Red arrows show examples of areas where images are mismatched.

Figure 4

Figure 5. Cross sectional views of the L-sample. White areas represent snow grains, black areas indicate the pore spaces and blue areas indicate the liquid (C12H26). (a) Height is 3.24 mm. (b) Height is 8.28 mm. (c) Height is 14.18 mm. (d) Height is 15.48 mm. (e) Height is 16.20 mm. (f) Height is 16.92 mm. (g) Height is 17.64 mm. (h) Height is 20.45 mm.

Figure 5

Figure 6. Vertical section views of the L-sample (distance of 12.53 mm). Distance is from the left side of the cross-sectional view. The left axis shows the height position of the cross sections in Figure 5.

Figure 6

Figure 7. Example of pore space analyses using a 3D watershed scheme. (a) 3D image of the reconstructed pore space based on X-ray CT images. (b) 3D image of segmented pore spaces with a 3D watershed scheme. Each color represents an individual pore space.

Figure 7

Figure 8. Images used in the analyses. (a) Image of the segmented pore spaces. Black areas indicate snow grains, and white areas indicate the pore spaces. The black lines in the figure indicate the boundaries between the pore spaces determined by the 3D watershed. (b) Superimposed MRI and segmented pore-space images. Black areas indicate snow grains, white areas indicate the pore spaces, and gray areas indicate liquids.

Figure 8

Figure 9. Analyses results. (a and d) Distribution of the area size of each pore space. The x-axis represents the pore space area, and the y-axis represents the ratio of the number of pore-space sizes divided into each class to the total number. a shows data of L-sample and d shows data of S-sample. (b and e) Distribution of the ratio of occupied pore space size by liquid divided into each class by its total number. The x-axis represents the pore space, and the y-axis represents the height of the cross-section from the bottom of the sample case (height resolution is 0.072 mm). The ratio of the pore space size of the liquid divided into each class to its total number is shown in the blue scale in the legend. b shows data of L-sample and e shows data of S-sample. (c and f) Ratio of pore spaces occupied by liquid to the total area. The x-axis is the ratio of the pore spaces occupied by liquid to the total area, and the y-axis is the height of the cross-section from the bottom of the sample case (height resolution is 0.072 mm). c shows data of L-sample and f shows data of S-sample.

Figure 9

Figure 10. Comparison of the WRC between the data of Adachi and others (2020) and the S-sample. The blue circles are data from the S sample, and the black triangles are data from Adachi and others (2020). Blue and black broken lines are the fitting curves of the VG model with each parameter in Table 1.

Figure 10

Table 1. Values of α and n in the VG model in Figure 10

Figure 11

Figure 11. Image and schematic diagram of the new sample case that we are developing. Case 2 is the same sample case shown in Figure 1 and case 2 is one size larger than case 1.

Figure 12

Table 2. Data for measured density of C12H24

Figure 13

Table 3. Data for measured surface tension of C12H24

Figure 14

Table 4. Data for measured viscosity coefficient of C12H24