Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-30T23:56:36.170Z Has data issue: false hasContentIssue false

Improved wireless power pickup efficiency using CMOS synchronous rectifier with embedded shorting control

Published online by Cambridge University Press:  06 March 2017

Robert Gallichan*
Affiliation:
Auckland Bioengineering Institute, The University of Auckland, Auckland 1142, New Zealand
Ho Yan (Alex) Leung
Affiliation:
Auckland Bioengineering Institute, The University of Auckland, Auckland 1142, New Zealand
David M. Budgett
Affiliation:
Auckland Bioengineering Institute, The University of Auckland, Auckland 1142, New Zealand
Aiguo Patrick Hu
Affiliation:
Department of Electrical and Computer Engineering, The University of Auckland, Auckland 1142, New Zealand
Daniel McCormick
Affiliation:
Auckland Bioengineering Institute, The University of Auckland, Auckland 1142, New Zealand
*
Corresponding author: R. Gallichan Email: [email protected]
Get access

Abstract

In this work, a shorting control (SC) scheme is integrated into a complementary metal-oxide-semiconductor (CMOS) synchronous rectifier for the output voltage regulation of a wireless power supply. The rectifier is designed to operate in a parallel tuned pickup with a 500 mW output power capability for biomedical implants. Without any additional components, the proposed SC method enables the power pickup to operate with high efficiency under variable coupling conditions while maintaining the required load power to keep the output voltage constant. Desired operating conditions are achieved with increased power transfer capability at weak magnetic coupling conditions and higher power efficiency at strong coupling. A novel derivation describes the change in efficiency with SC duty ratio. Experimental validation is completed with an original custom CMOS integrated rectifier with embedded SC. It is demonstrated that the proposed SC method can increase the overall secondary pickup power transfer efficiency by 14% as the magnetic coupling increases to the stronger end.

Type
Research Article
Copyright
Copyright © Cambridge University Press 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Mestais, C.S.; Charvet, G.; Sauter-Starace, F.; Foerster, M.; Ratel, D.; Benabid, A.L.: WIMAGINE: wireless 64-channel ECoG recording implant for long term clinical applications. IEEE Trans. Neural Syst. Rehabilitat. Eng., 23 (1) (2015), 1021.Google Scholar
[2] Ghovanloo, M.; Najafi, K.: A wireless implantable multichannel microstimulating system-on-a-chip with modular architecture. IEEE Trans. Neural Syst. Rehabilitation Eng., 15 (3) (2007), 449457.Google Scholar
[3] Hu, A.P.; You, Y.W.; Chen, F.Y.B.; McCormick, D.; Budgett, D.M.: Wireless power supply for ICP devices with hybrid supercapacitor and battery storage. IEEE J. Emerging Sel. Topics Power Electron., 4 (1) (2016), 273279.Google Scholar
[4] Gowrishankar, T.R.; Stewart, D.A.; Martin, G.T.; Weaver, J.C.: Transport lattice models of heat transport in skin with spatially heterogeneous, temperature-dependent perfusion. Biomed. Eng. Online, 3 (2004), 42.Google Scholar
[5] Fujii, T.; Ibata, Y.: Effects of heating on electrical activities of guinea pig olfactory cortical slices. Pflügers Arch., 392 (3) (1982), 257260.CrossRefGoogle ScholarPubMed
[6] Bawa, G.; Ghovanloo, M.: Analysis, design, and implementation of a high-efficiency full-wave rectifier in standard CMOS technology. Analog Integr. Circuits Signal Process., 60 (1–2) (2009), 7181.Google Scholar
[7] Lu, Y.; Ki, W.-H.: A 13.56 MHz CMOS active rectifier with switched-offset and compensated biasing for biomedical wireless power transfer systems. IEEE Trans. Biomed. Circuits Syst., PP (99) (2013), 1.Google Scholar
[8] Borton, D. A.; Yin, M.; Aceros, J.; Nurmikko, A.: An implantable wireless neural interface for recording cortical circuit dynamics in moving primates. J. Neural Eng., 10 (2) (2013), 26010.CrossRefGoogle ScholarPubMed
[9] Park, H.G. et al. : A design of a wireless power receiving unit with a high-efficiency 6.78-MHz active rectifier using shared DLLs for magnetic-resonant A4 WP applications. IEEE Trans. Power Electron., 31 (6) (2016), 44844498.CrossRefGoogle Scholar
[10] Leung, H. Y.; Budgett, D. M.; Hu, A. P.: Minimizing power loss in air-cored coils for TET heart pump systems. IEEE J. Emerging Sel. Top. Circuits Syst., 1 (3) (2011), 412419.Google Scholar
[11] Si, P.; Hu, A.P.; Malpas, S.; Budgett, D.: A frequency control method for regulating wireless power to implantable devices. IEEE Trans. Biomed. Circuits Syst., 2 (1) (2008), 2229.Google Scholar
[12] Dissanayake, T.D. et al. : A novel low temperature transcutaneous energy transfer system suitable for high power implantable medical devices: performance and validation in sheep. Artif. Organs, 34 (5) (2010), E160E167.Google Scholar
[13] Covic, G.A.; Boys, J.T.: Inductive power transfer. IEEE Proc., 101 (6) (2013), 12761289.CrossRefGoogle Scholar
[14] Boys, J.T.; Green, A.W.: Inductive power distribution system. U.S. Patent 5 293 308 A, March 1994.Google Scholar
[15] Boys, J. T.; Covic, G. A.: Decoupling circuits. U.S. Patent 7 474 062 B2, 21 October 2004.Google Scholar
[16] Lee, H.-M.; Ghovanloo, M.: An integrated power-efficient active rectifier with offset-controlled high speed comparators for inductively powered applications. IEEE Trans, Circuits Syst. I, Regul. Pap., 58 (8) (2011), 17491760.CrossRefGoogle ScholarPubMed
[17] Lee, B.; Kiani, M.; Ghovanloo, M.: A triple-loop inductive power transmission system for biomedical applications. IEEE Trans. Biomed. Circuits Syst., 10 (1) (2016), 138148.Google Scholar
[18] Kiani, M.; Lee, B.; Yeon, P.; Ghovanloo, M.: A Q-modulation technique for efficient inductive power transmission. IEEE J. Solid-State Circuits, 50 (12) (2015), 28392848.CrossRefGoogle ScholarPubMed
[19] Li, X.; Tsui, C.Y.; Ki, W.H.: A 13.56 MHz wireless power transfer system with reconfigurable resonant regulating rectifier and wireless power control for implantable medical devices. IEEE J. Solid-State Circuits, 50 (4) (2015), 978989.CrossRefGoogle Scholar
[20] Lu, Y.; Li, X.; Ki, W.H.; Tsui, C.Y.; Yue, C.P.: A 13.56 MHz fully integrated 1X/2X active rectifier with compensated bias current for inductively powered devices, in 2013 IEEE Int. Solid-State Circuits Conf. Digest Tech. Papers, 2013, 66–67.Google Scholar
[21] McCormick, D.: Powering Implantable Devices from a Surface: with Application to Physiological Monitoring in Mice. PhD dissertation, ABI, The University of Auckland, 2011.Google Scholar
[22] Lenaerts, B.; Puers, R.: Omnidirectional Inductive Powering for Biomedical Implants, 1st ed., Springer, Netherlands, 2009.Google Scholar
[23] Si, P.; Hu, A. P.: Analyses of DC inductance used in ICPT power pick-ups for maximum power transfer, in 2005 IEEE/PES Transmission Distribution Conf. Exposition: Asia Pacific, Dalian, 2005, 1–6.Google Scholar
[24] Stehlin, E.F.; McCormick, D.; Malpas, S.C.; Pontré, B.P.; Heppner, P.A.; Budgett, D.M.: MRI interactions of a fully implantable pressure monitoring device. J. Magn. Reson. Imaging, 42 (5) (2015), 14411449.Google Scholar