Hostname: page-component-78c5997874-m6dg7 Total loading time: 0 Render date: 2024-11-16T07:30:18.937Z Has data issue: false hasContentIssue false

Multi-link active catheter snake-like motion

Published online by Cambridge University Press:  09 March 2009

Geunbae Lim
Affiliation:
Faculty of Engineering, Tohoku University, Sendai, 980–77 (Japan).
Kazuyuki Minami
Affiliation:
Faculty of Engineering, Tohoku University, Sendai, 980–77 (Japan).
Keisuke Yamamoto
Affiliation:
Mitsubishi Cable Industries, LTD., Itami, 664 (Japan).
Masahisa Sugihara
Affiliation:
Mitsubishi Cable Industries, LTD., Itami, 664 (Japan).
Masaru Uchiyama
Affiliation:
Faculty of Engineering, Tohoku University, Sendai, 980–77 (Japan).
Masayoshi Esashi
Affiliation:
Faculty of Engineering, Tohoku University, Sendai, 980–77 (Japan).

Summary

A prototype of a catheter which can move like a snake, incorporating distributed shape memory alloy actuators, is described. Since this active catheter has an instrumental navigation ability, minimally invasive diagnosis and interventional therapy will be possible. The outer diameter of the active catheter is 2.8 mm and it has many links fabricated by 3-dimensional silicon micromachining. The silicon batch process was used for the fabrication of the link to minimize assembly work. A new heating method (indirect heating) is suggested which is necessary when the JC chip is mounted on the link.

Type
Article
Copyright
Copyright © Cambridge University Press 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Dotter, C.T. and Judkins, M.P.Transluminal treatment of arteriosclerotic obstruction: description of a new technique and a preliminary report of its applicationCirculation 30, 654–670 (1964).CrossRefGoogle Scholar
2. Levy, R.I., Mock, M.B., Willman, V.L. et al. “Percutaneous transluminal coronary angioplastyN. Engl. J. Med. 301, 101–103 (1979).CrossRefGoogle ScholarPubMed
3. Simpson, J.B., Bairn, D.S., Robert, E.W. et al. “A new catheter system for coronary angioplastyAm. J. Cardiol. 49, 1216–1222 (1982).CrossRefGoogle ScholarPubMed
4. Marks, L.A., Short, K.L., Hoffman, D. and Lew, A.Microprocessor-board robotic system for control of fluid connections in the cardiac catheterization LaboratoryIEEE Trans. Biomed. Eng. BME-35, No. 2, 161–166. (1988).Google Scholar
5. Ikuta, K. “The Application of Micro/Miniature Mechatronics to Medical Robotics” Proc. IEEE/IROS, Tokyo, Japan (1988) pp. 9–14.Google Scholar
6. Lim, G., Minami, K., Sugihara, M., Uchiyama, M. & Esashi, M. “Active Catheter with Multi-Link Structure Based on Silicon Micromachining” Proc. IEEE/MEMS'95,Amsterdam, Netherlands(1995) pp. 116–121.Google Scholar
7. Haga, Y., Minami, K., Shoji, S., Nitta, S., Tanaka, M. & Esashi, M. “A Fiber-Optic Ultra Miniature Pressure Sensor” Technical Digest of the 12th Sensor Symposium, Osaka, Japan (1994) pp. 135–138.Google Scholar
8. Esashi, M., Lira, N. & Matsumoto, Y. “Anodic Bonding for Integrated Captive Sensors” Proc. IEEE/MEMS'92,Travemunde, Germany(1992) pp. 43–48.Google Scholar
9. Sugihara, M. & Yamamoto, K.Researchers on Shape Memory Alloys Micro ActuatorsMitsubishi Cable Industries Reviews, No. 87, 70–73 (1994).Google Scholar
10. Esashi, M. & Matsumoto, Y. “Common Two Lead Wires Sensing System “Digest of Technical Papers of Transducers 91, San Francisco, America (1991) pp. 330–333.Google Scholar
11. Lim, G., Minami, K. & Esashi, M. “Indirect Heating Type SMA Actuator, Late news of the 12th Sensor Symposium, Osaka, Japan (1994) p. 78.Google Scholar
12. Szwarc, M.Poly-para-Xylene: Its Chemistry and Application in Coating TechnologyPolymer Engineering and Science 16, 473–479 (1976).CrossRefGoogle Scholar