Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-24T18:55:09.298Z Has data issue: false hasContentIssue false

Evaluation of Success Rate and Access Time for an Adult Sternal Intraosseous Device Deployed in the Prehospital Setting

Published online by Cambridge University Press:  03 May 2011

Donald V. Byars*
Affiliation:
Department of Emergency Medicine, Eastern Virginia Medical School, Norfolk, Virginia USA
Sara N. Tsuchitani
Affiliation:
Department of Emergency Medicine, Eastern Virginia Medical School, Norfolk, Virginia USA
Eleanor Erwin
Affiliation:
Department of Emergency Medicine, Eastern Virginia Medical School, Norfolk, Virginia USA
Bradley Anglemyer
Affiliation:
Department of Emergency Medicine, Eastern Virginia Medical School, Norfolk, Virginia USA
*
Correspondence: Dr. Donald V. Byars 600 Gresham DriveRaleigh Building, Suite 304Norfolk, VA 23510 USA Email: [email protected]

Abstract

Introduction: Access to the vascular system of the critically ill or injured adult patient is essential for resuscitation. Whether due to trauma or disease, vascular collapse may delay or preclude even experienced medical providers from obtaining standard intravenous (IV) access. Access to the highly vascular intramedullary space of long bones provides a direct link to central circulation. The sternum is a thin bone easily identified by external landmarks that contains well-vascularized marrow. The intraosseous (IO) route rapidly and reliably delivers fluids, blood products, and medications. Resuscitation fluids administered by IV or IO achieve similar transit times to central circulation. The FAST-1 Intraosseous Infusion System is the first FDA-approved mechanical sternal IO device. The objectives of this study were to: (1) determine the success rate of FAST-1 sternal IO device deployment in the prehospital setting; (2) compare the time of successful sternal IO device placement to published data regarding time to IV access; and (3) describe immediate complications of sternal IO use.

Methods: All paramedics in the City of Portsmouth, Virginia were trained to correctly deploy the FAST-1 sternal IO device during a mandatory education session with the study investigators. The study subjects were critically ill or injured adult patients in cardiac arrest treated by paramedics during a one-year period. When a patient was identified as meeting study criteria, the paramedic initiated standard protocols; the FAST-1 sternal IO was substituted for the peripheral IV to establish vascular access. Time to deployment was measured and successful placement was defined as insertion of the needle, with subsequent aspiration and fluid flow without infiltration.

Results: Over the one-year period, paramedics attempted 41 FAST-1 insertions in the pre-hospital setting. Thirty (73%) of these were placed successfully. The mean time to successful placement was 67 seconds for 28 attempts; three of the 31 insertions did not have times recorded by the paramedic. Paramedics listed the problems with FAST-1 insertion, including: (1) difficulty with adhesive after device placement (3 events); (2) failure of needles to retract and operator had to pull the device out of the skin (2 events); and (3) slow flow (1 event). Emergency department physicians noted two events of minor bleeding around the site of device placement.

Conclusion: This is the first study to prospectively evaluate the prehospital use of the FAST-1 sternal IO as a first-line device to obtain vascular access in the critically ill or injured patient. The FAST-1 sternal IO device can be a valuable tool in the paramedic arsenal for the treatment of the critically ill or injured patient. The device may be of particular interest to specialty disaster teams that deploy in austere environments.

Type
Brief Report
Copyright
Copyright Byars © World Association for Disaster and Emergency Medicine 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Drinker, CK, Drinker, KR, Lund, CC: The circulation of the mammalian bone marrow. Am J Physiol 1922;62:192.CrossRefGoogle Scholar
Orlowski, JP, Porembka, DT, Gallagher, JM, et al: Comparison study of intraosseous, central intravenous, and peripheral intravenous infusions of emergency drugs. Am J Dis Child 1990;140:112117.Google Scholar
Cameron, JL, Fontanarosa, PB, Passalaqua, AM: A comparative study of peripheral to central circulation delivery times between intraosseous and intravenous injection using radionuclide technique in normovolemic and hypovolemic canines. J Emerg Med: 1989;7:123127.CrossRefGoogle ScholarPubMed
Horwood, BT, Adams, J, Tiffany, BR, et al: Prehospital use of a sternal intraosseous infusion device. Ann Emerg Med 1999;34(4):s65s66.CrossRefGoogle Scholar
Frascone, RJ, Jensen, JP, Kaye, K, et al: Consecutive field trials using two different intraosseous devices. Prehosp Emerg Care 2007;11(2):164171.CrossRefGoogle ScholarPubMed
Macnab, A, Christenson, J, Findlay, J, et al: A new system for sternal intraosseous infusion in adults. Prehosp Emerg Care 2000;4(2):173177.CrossRefGoogle ScholarPubMed
Rossetti, V, Thompson, BM, Aprahamian, C, et al: Difficulty and delay in intravascular access in pediatric arrests. Ann Emerg Med 1985;14(9):885888.Google Scholar
McSwain, GR, Garrison, WB, Artz, CP: Evaluation of resuscitation from cardiopulmonary arrest by paramedics. Ann Emerg Med 1980;9(7):341345.CrossRefGoogle ScholarPubMed