Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-28T22:19:56.898Z Has data issue: false hasContentIssue false

X-ray powder diffraction data for bisacodyl, C22H19NO4

Published online by Cambridge University Press:  10 June 2014

Shan Shan Li
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Xiao Qing Wu
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Qing Wang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Pei Xiao Tang
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
Hui Li*
Affiliation:
College of Chemical Engineering, Sichuan University, Chengdu 610065, China
*
a)Author to whom correspondence should be addressed. Electronic mail: [email protected]

Abstract

In this paper, X-ray powder diffraction data, unit-cell parameters, and space group for bisacodyl, C22H19NO4, are reported [a = 9.081(3) Å, b = 10.631(5) Å, c = 11.549(6) Å, α = 111.492(4)°, β = 108.082(3)°, γ = 101.501(3)°, unit-cell volume V = 922.368 Å3, Z = 2, and space group P-1]. All measured lines were indexed, and no detectable impurity was observed.

Type
New Diffraction Data
Copyright
Copyright © International Centre for Diffraction Data 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Adams, W. J., Meagher, A. P., Lubowski, D. Z., and King, D. W. (1994). “Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation,” Dis. Colon Rectum 37, 229234.Google Scholar
Clark, R. E., Godfrey, J. D., Choudhary, A., Ashraf, I., Matteson, M. L., and Bechtold, M. L. (2013). “Low-volume polyethylene glycol and bisacodyl for bowel preparation prior to colonoscopy: a meta-analysis,” Ann. Gastroenterol. 26, 319324.Google Scholar
Engel, G. E., Wilke, S., König, O., Harris, K. D. M., and Leusen, F. J. J. (1999). “Powder solve-a complete package for crystal structure solution from powder diffraction patterns,” J. Appl. Crystallogr. 32, 11691179.CrossRefGoogle Scholar
Li, S. S., Wu, X. Q., Pan, Q. Q., Cheng, Q., and Li, H. (2014). “Comparison of the accuracy of powder and single-crystal X-ray diffraction techniques in determining organic crystal structure,” Chin. Sci. Bull. 59, 497501.CrossRefGoogle Scholar
Neumann, M. A. (2003). “ X-Cell: a novel indexing algorithm for routine tasks and difficult cases,” J. Appl. Crystallogr. 36, 356365.Google Scholar
Sánchez-Bajo, F., and Cumbrera, F. L. (1997). “The use of the Pseudo-Voigt function in the variance method of X-ray line-broadening analysis,” J. Appl. Crystallogr. 30, 427430.Google Scholar
Young, R. A. (1993). The Rietveld Method, IUCr Monographies of Crystallography (Wiley, Oxford).Google Scholar
Supplementary material: File

Li Supplementary Material

Li Supplementary Material

Download Li Supplementary Material(File)
File 305.4 KB