Methods of Producing Standard X-Ray Diffraction Powder Patterns

Published online by Cambridge University Press:  10 January 2013

Howard F. McMurdie
Affiliation:
JCPDS — International Centre for Diffraction Data1
Marlene C. Morris
Affiliation:
JCPDS — International Centre for Diffraction Data1
Eloise H. Evans
Affiliation:
JCPDS — International Centre for Diffraction Data1
Boris Paretzkin
Affiliation:
JCPDS — International Centre for Diffraction Data1
Winnie Wong-NG
Affiliation:
JCPDS — International Centre for Diffraction Data1
Camden R. Hubbard
Affiliation:
National Bureau of Standards

Abstract

Patterns useful for identification are obtained by automated diffractometer methods. The lattice constants from the experimental work are refined by least-squares methods; reflections are assigned hkℓ indices consistent with space group extinctions. Relative intensities, calculated densities, literature references, and other relevant data are included.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1986

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Alexander, L., Klug, H. P., and Kummer, E. (1948). J. Appl. Phys, 19, No. 8, 742.CrossRefGoogle Scholar
Appleman, D. E. and Evans, H. T. Jr., (1973). Report # PB216188, U. S. Dept., of Commerce, National Technical Information Service, 5285 Port Royal Rd., Springfield, VA 22151.Google Scholar
Chemical Abstracts Service Registry Handbook–Number Section (1974), (The American Chemical Society, Chemical Abstracts Service, The Ohio State Univ., Columbus, OH43210).Google Scholar
Crystal Data (1983). (3rd Ed. Published jointly by the U.S. Dept. of Commerce, Natl. Bur. Stand., Gaithersburg, MD20899, and the JCPDS — International Centre for Diffraction Data, 1601 Park Lane, Swarthmore, PA 19081.)Google Scholar
Daniels, R. W. (1978). An Introduction to Numerical Methods and Optimization Techniques, (Elsevier North-Holland Inc., New York), 78.Google Scholar
Deslattes, R. D. and Henins, A. (1973). Phys. Rev. Lett. 31, 972.CrossRefGoogle Scholar
Deslattes, R. D., Henins, A., Bowman, H. A., Schoonover, R. M., Carroll, C. L., Barnes, I. L., Machlan, L. A., Moore, L. J., and Shields, W. R. (1974). Phys. Rev. Lett. 33, 463.CrossRefGoogle Scholar
Donnay, J. D. H. and Kennard, O. (1964). Acta Crystallogr. 17, 1337.CrossRefGoogle Scholar
Groth, P. (1908). Chemische Kristallographie II, (Engelmann, Leipzig, Germany).Google Scholar
Hubbard, C. R. (1982). J. Appl. Crystallogr. 16, 285.CrossRefGoogle Scholar
Hubbard, C. R. (1983). Private Communication.Google Scholar
Hubbard, C. R. and Calvert, L. D. (1981). Bull. Alloy Phase Dia. 2, 153.CrossRefGoogle Scholar
International Tables for Crystallography, A (1983), (Reidel Publishing Co., Dordrecht, Holland).Google Scholar
International Union of Pure and Applied Chemistry (1979). Pure Appl. Chem. 51, No. 2, 407.Google Scholar
ISCC-NBS Centroid Color Charts, SRM 2106 (1965) or Color Kit, SRM 2107 (1977) which contains both SRM 2106 and Color, an NBS Special Publication #SP 440. These can be obtained from the Natl. Bur. of Stand., Office of Standard Reference Materials, Gaithersburg, MD 20899. Current prices will be quoted on request.Google Scholar
Mighell, A. D., Hubbard, C. R., and Stalick, J. K. (1981). NBS Technical Note 1141, U. S. Dept. of Commerce, Natl. Bur. Stand., Gaithersburg, MD 20899.Google Scholar
Morris, M. C., McMurdie, H. F., Evans, E. H., Paretzkin, B., Parker, H. S., Wong-Ng, W., Gladhill, D. M., and Hubbard, C. R. (1985). Natl. Bur. Stand. (U.S.) Monogr. 25, 21, iv.Google Scholar
Palache, C., Berman, H., and Frondel, C. (1944). Dana's System of Mineralogy I (John Wiley and Sons, New York, 7th Ed.), 6.Google Scholar
Pyrros, N. P. and Hubbard, C. R. (1983). Advances in X-ray Analysis (Plenum Publishing Corporation, New York, NY 10013), 26, 63.Google Scholar
Savitzky, A. and Golay, M. J. E. (1964). Anal. Chem. 36, 1627.CrossRefGoogle Scholar
Smith, G. S. and Snyder, R. L. (1979). J. Appl. Crystallogr. 12, 60.CrossRefGoogle Scholar
Snyder, R. L., Hubbard, C. R., and Panagiotopoulos, N. C. (1981). Auto: A Real Time Diffractometer Control System Report, NBSIR 81-2229, U. S. Dept. of Commerce, Natl. Bur. Stand., Gaithersburg, MD20899.CrossRefGoogle Scholar
Standard Reference Material 640a (1982), Silicon Powder X-ray Diffraction Standard, obtainable from the Natl. Bur. of Stand., Office of Standard Reference Materials, Gaithersburg, MD 20899. Current price will be quoted on request.Google Scholar
Standard Refference Material 675 (1982), Fluorophlogopite Powder X-ray Diffraction Standard. To obtain, see procedure above for SRM 640a.Google Scholar
Visser, J. W. (1969). J. Appl. Crystallogr. 2, 89.CrossRefGoogle Scholar
Wolff, de P. M. (1968). J. Appl. Crystallogr. 1, 108.CrossRefGoogle Scholar