Introduction
Planetary accretion and metallic core formation
Seismological data show that currently the Earth consists of a dense inner solid and outer liquid metallic core (Fig. 1), surrounded by a silicate shell (bulk silicate earth, BSE) comprising a mantle and a crust (e.g. Birch, Reference Birch1952). This large-scale internal differentiation occurred within the first 100 million years of the formation of the solar system and the Earth, and is linked to early planetary accretion processes.
Planetary accretion proceeds by collisions of planetesimals and smaller planetary bodies on a timescale of thousands of years in the terrestrial planet zone of our solar system. Larger planetesimals grow by gravitationally sweeping up smaller ones, leading to larger bodies growing more rapidly than the smaller planetesimals. This so-called ‘runaway growth process’ (e.g. Kortenkamp et al., Reference Kortenkamp, Wetherill and Inaba2001; Inaba et al., Reference Inaba, Tanaka, Nakazawa, Wetherill and Kokubo2001) led to the formation of several tens of Moon- to Mars-sized planetary embryos in the terrestrial planet zone. Final accretion of today's terrestrial planets took place through large impact events (e.g. Wetherill, Reference Wetherill1985; Stevenson, Reference Stevenson, Newsom and Jones1990; Chambers, Reference Chambers2004; Wood & Halliday, Reference Wood and Halliday2005).
The kinetic energy of small and large collisions is converted into thermal energy. The build-up of heat, in combination with heat production through natural radioactive decay, led to widespread melting and the formation of deep magma oceans on most if not on all the terrestrial planets and the Moon (e.g. Yoshino et al., Reference Yoshino, Walter and Katsura2003; Rubie et al., Reference Rubie, Melosh, Reid, Liebske and Righter2003; Elkins-Tanton, Reference Elkins-Tanton2012; Rai & Van Westrenen, Reference Rai and Van Westrenen2013, Reference Rai and Van Westrenen2014). As a consequence of large-scale melting, the planets, including the primitive Earth, differentiated into a dense metallic core and a siliceous mantle. Measurements comparing the tungsten isotopic compositions of chondritic meteorites and BSE indicate that the main stage of terrestrial core segregation probably took place between 30 and 60 Ma after the formation of the solar system (e.g. Yin et al., Reference Yin, Jacobsen, Yamashita, Blichert-Toft, Télouk and Albarède2002; Burkhardt et al., Reference Burkhardt, Kleine, Bourdon, Palme, Zipfel, Friedrich and Ebel2008).
The geochemical and geophysical signature of the Earth and its core
Since it is impossible to obtain samples from the Earth's deepest interior, information on the Earth's bulk chemical composition and its core can only be acquired indirectly, by investigating meteorites and by sampling the accessible parts of the silicate Earth. Additional indirect evidence can be gained from seismic observations. These geochemical and geophysical investigations yield models for the composition of the BSE and the bulk earth (BE), from which the chemical composition of the core can be estimated using simple mass balance.
Chemical composition of BSE and BE.
Accretion and planetary differentiation have both influenced element abundances in the Earth's mantle. Based on element concentrations of the Earth's mantle derived from mantle xenoliths and Mid-Ocean Ridge Basalt analyses (e.g. Allègre et al., Reference Allègre, Poirier, Humler and Hofmann1995; McDonough & Sun, Reference McDonough and Sun1995), it was found that BSE for many elements is chemically related to carbonaceous (CI) chondrites – the most primitive chondritic meteorites in our solar system, which are believed to form the main building blocks of Earth.
Geochemically distinct groups of elements show different degrees of depletion in the Earth's mantle compared to the composition of these CI chondrites. This observed depletion appears to depend in part on the elemental condensation temperatures (e.g. Lodders, Reference Lodders2003). Elements including Zr, Mg, and rare earth elements are lithophile and prefer to partition into silicates over metallic or sulphide phases. They are also non-volatile or refractory elements, and their relative abundances in BSE are comparable to their relative abundances in CI chondrites. These elements were not removed from the mantle by differentiation processes and were not lost before or during Earth formation by volatilisation. In contrast, more volatile lithophile elements are depleted from the Earth's mantle relative to CI chondrites either as a result of partial condensation from the solar nebula or due to their volatility during high-temperature planetary accretion processes.
The 50% condensation temperature of an element can approximate its volatility degree. By definition, this is the temperature at which half of the number of atoms of the element reside in a solid phase and half in the gas phase. Fig. 2 shows a simplified illustration of the observed abundances of lithophile elements and iron in the Earth's mantle, normalised to CI chondrite element abundances and Mg, versus their 50% condensation temperatures determined thermodynamically (data from McDonough, Reference McDonough2003; Lodders, Reference Lodders2003). The trend of decreasing abundance of moderately lithophile elements with decreasing 50% condensation temperature is called the Earth's volatility trend. With respect to the composition of the core it is assumed that the solid grey line in Fig. 2 defines the composition of the BE. The grey arrow at the left-hand side of Fig. 2 indicates the Earth's volatility trend.
Geophysical constraints on core composition.
The presence of a core–mantle boundary (CMB) in the Earth was first suspected at a depth of 2900 km (Figs 1 and 3) by Oldham (Reference Oldham1906) and was subsequently confirmed on the basis of seismic measurements and calculations by Gutenberg (Reference Gutenberg1914) and Jeffreys (Reference Jeffreys1935). Temperature estimates of today's Earth's core range from 4000 to 7000 K and pressures vary between 136 and 364 GPa from the CMB to the Earth's centre. The inner core consists of a solidified iron–nickel alloy. A primary feature of Earth's present-day liquid outer core is its so-called core density deficit (CDD), referring to the seismological observation that the outer core density is between 2.5% and 10% lower than expected for a molten iron–nickel alloy (Fig. 3; Birch, Reference Birch1952, Reference Birch1964; Anderson & Isaak, Reference Anderson and Isaak2002).
The CDD can be explained by the incorporation of one or more light elements into the core (e.g. Poirier, Reference Poirier1994; Javoy, Reference Javoy1999; Dreibus & Palme, Reference Dreibus and Palme1996; Li & Fei, Reference Li, Fei and Carlson2003). In addition to sulfur (e.g. Brett, Reference Brett1984), oxygen (e.g. Corgne et al., Reference Corgne, Siebert and Badro2009), hydrogen (e.g. Okuchi, Reference Okuchi1997) and carbon (e.g. Wood, Reference Wood1993; Dasgupta & Walker, Reference Dasgupta and Walker2008), silicon has been proposed as a ‘key’ light element in the outer Earth's core (e.g. MacDonald & Knopoff, Reference MacDonald and Knopoff1958; Birch, Reference Birch1964; Ringwood, Reference Ringwood1966; Tuff et al., Reference Tuff, Wood and Wade2011). The Earth is not unique in having light elements in its core: light elements are also known to be present in the cores of the Moon (e.g. Rai & Van Westrenen, Reference Rai and Van Westrenen2014), Mars (e.g. Rai & Van Westrenen, Reference Rai and Van Westrenen2013) and Mercury (e.g. Dumberry & Rivoldini, Reference Dumberry and Rivoldini2014; Knibbe & Van Westrenen, Reference Knibbe and van Westrenen2015), as well as differentiated asteroids such as Vesta (e.g. Steenstra et al., Reference Steenstra, Knibbe, Rai and Van Westrenen2015). The nature and abundance of light elements in a planetary core provide a fingerprint for planetary core formation conditions, and therefore provide constraints on early planetary evolution. For example, Si can only be incorporated into metal at oxygen-poor (highly reducing) conditions – conditions that are not present in the Earth today. If Si is present in Earth's core, the Earth must have been much less oxygen-rich when its core formed than it is today.
The role of Si stable isotopes
Due to the advent of multi-collector (MC) ICPMS techniques, it has become possible in recent years to approach the specific question of Si incorporation into the core of the Earth and other planetary bodies by studying the distribution of Si stable isotopes (28Si, 29Si and 30Si) between metals and silicates, either by comparing isotopic signatures of terrestrial and extra-terrestrial silicate samples or by measuring their distribution in coexisting metal and silicate phases equilibrated in experiments simulating conditions of core formation. Isotope-geochemical investigations of terrestrial mantle rocks, as well as lunar samples (summarised in Fig. 4), show slightly higher δ30Si (δ30Si = [((30Si/28Sisample)/(30Si/28Sistandard)) – 1] × 1000 [‰]) values than undifferentiated meteorites (Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007; Fitoussi et al., Reference Fitoussi, Bourdon, Kleine, Oberli and Reynolds2009; Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010; Chakrabarti & Jacobsen, Reference Chakrabarti and Jacobson2010; Armytage et al., Reference Armytage, Georg, Savage, Williams and Halliday2011, Reference Armytage, Georg, Williams and Halliday2012; Savage & Moynier, Reference Savage and Moynier2013; see recent compilation by Savage et al., Reference Savage, Armytage, Georg and Halliday2014). The average δ30Si isotopic signature of terrestrial mantle rocks is estimated to be –0.29‰ ± 0.07‰, 2SD (Douthitt, Reference Douthitt1982; Georg et al. Reference Georg, Halliday, Schauble and Reynolds2007; Fitoussi et al., Reference Fitoussi, Bourdon, Kleine, Oberli and Reynolds2009; Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010; Savage et al., Reference Savage, Georg, Armytage, Williams and Halliday2010; Chakrabarti & Jacobsen, Reference Chakrabarti and Jacobson2010; Armytage et al., Reference Armytage, Georg, Savage, Williams and Halliday2011, Reference Armytage, Georg, Williams and Halliday2012; Savage & Moynier, Reference Savage and Moynier2013; Savage et al., Reference Savage, Armytage, Georg and Halliday2014; see Fig. 4). The average δ30Si isotopic signature for carbonaceous and ordinary chondrites (δ30SiCHUR) is –0.47‰ ± 0.06‰ (Molini-Velsko et al., Reference Molini-Velsko, Mayeda and Clayton1986; Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007; Fitoussi et al., Reference Fitoussi, Bourdon, Kleine, Oberli and Reynolds2009; Chakrabarti & Jacobsen, Reference Chakrabarti and Jacobson2010; Armytage et al., Reference Armytage, Georg, Savage, Williams and Halliday2011, Reference Armytage, Georg, Williams and Halliday2012; Fitoussi & Bourdon, Reference Fitoussi and Bourdon2012; Savage & Moynier, Reference Savage and Moynier2013; Savage et al., Reference Savage, Armytage, Georg and Halliday2014; Fig. 4).
The absolute isotopic difference between CI chondrites and the BSE of Δ30SiBSE–CHUR = 0.18‰ ± 0.06‰ (where Δ30SiA–B = δ30SiA – δ30SiB) has been explained by equilibrium metal–silicate Si isotope fractionation at high-temperature and high-pressure (HPT) conditions at reducing oxygen conditions (e.g. Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007; Shahar et al., Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011; Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010; Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a; Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014), driven by the different chemical bonding environment of Si in silicate rocks versus metallic liquid (Schauble et al., Reference Schauble, Méheut and Hill2007; Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007). If Si isotope fractionation between metal and silicate is an equilibrium process, the heavier isotopes fractionate preferentially into the stiffer bonded phase, in this case the silicate. Heavier Si isotopes fractionating into the silicate, and lighter isotopes fractionating into the metal was observed in meteorite samples that contain both metal and silicate phases: first in enstatite chondrites, comprising a Si-bearing metal and a silicate phase (Molini-Velsko et al., Reference Molini-Velsko, Mayeda and Clayton1986), and subsequently by Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010), who assumed Si isotope equilibration between metal and silicate in two aubrite meteorites occurred through solid-state diffusion.
If metal–silicate equilibration is the cause of the observed difference between CI chondrites and BSE Si isotopic composition, (1) Si must be present in the Earth's core and (2) the Earth's core Si isotopic signature must be isotopically lighter than the Si isotopic signature of the BSE (Fig. 4).
Evidence for Si in the Earth's outer core
Geochemical and geophysical lines of evidence support the hypothesis that Si is one of the light elements in the outer Earth's core, but uncertainty about its concentration remains substantial. The latest geophysical models suggest that the Earth's core contains up to 4.5 wt% Si, in addition to significant amounts of oxygen (e.g. Badro et al., Reference Badro, Côté and Brodholt2014). The experimental observation that Si becomes more siderophile with increasing pressure and temperature conditions and decreasing oxygen fugacity could explain the observed slight depletion of Si in the silicate portion of the Earth compared to its predicted BSE concentration using the Earth's volatility trend (Fig. 2).
The observed superchondritic Mg/Si and Al/Si ratios in the primitive upper mantle (e.g. Allègre et al., Reference Allègre, Poirier, Humler and Hofmann1995; Drake & Righter, Reference Drake and Righter2002) can be reconciled with chondritic models of bulk Earth composition by incorporating approximately 6 wt% of Si in the core (e.g. McDonough, Reference McDonough2003).
The experimentally determined element partitioning behaviour of Si and a range of other siderophile elements suggest the presence of anywhere between 1 and 11 wt% Si in the core (e.g. Ricolleau et al., Reference Ricolleau, Fei, Corgne, Siebert and Badro2011). Although this is qualitatively consistent with cosmochemical arguments, constraints from Si partitioning data are currently not precise enough to distinguish between different core formation scenarios.
Translation of the observed Si isotope fractionation between the BSE and the Earth's building blocks (~0.2 per mille in terms of Δ30Si) into corresponding core Si concentrations requires knowledge of Si isotope fractionation factors between silicate and iron metal at HPT conditions. To date, these have mostly been predicted using theoretical calculations (e.g. Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007; Fitoussi et al., Reference Fitoussi, Bourdon, Kleine, Oberli and Reynolds2009; Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010; Chakrabarti & Jacobsen, Reference Chakrabarti and Jacobson2010; Armytage et al., Reference Armytage, Georg, Savage, Williams and Halliday2011), suggesting that the Si concentration in the Earth's outer core could comprise between 2.5 and 16.8 wt% Si (Armytage et al., Reference Armytage, Georg, Savage, Williams and Halliday2011), a range that is even larger than the range derived from the Si elemental partitioning data given above (1–11 wt%; Ricolleau et al., Reference Ricolleau, Fei, Corgne, Siebert and Badro2011).
The role of HPT experiments
HPT experimental metal–silicate systems aim to simulate the elemental and/or isotopic distribution between planetary cores and mantles. HPT experiments on the elemental partitioning behaviour of Si between metal and silicate have shown that Si becomes more siderophile (iron metal-loving) with increasing pressure and temperature, and decreasing oxygen fugacity (e.g. Kilburn & Wood, Reference Kilburn and Wood1997; Gessmann et al., Reference Gessmann, Wood, Rubie and Kilburn2001; Malavergne et al., Reference Malavergne, Siebert, Guyot, Gautron, Combes, Hammouda, Borensztan, Frost and Martinez2004; Wade & Wood, Reference Wade and Wood2005; Corgne et al., Reference Corgne, Siebert and Badro2009; Tuff et al., Reference Tuff, Wood and Wade2011).
Experimental studies on Si isotope fractionation between metal and silicate were carried out by Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) at pressures of 1 and 7 GPa, and temperatures between 1800 and 2200°C. Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) did experiments at 9 GPa and ~2150°C. Kempl et al. (Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b) approached the study of Si isotope fractionation processes at high temperature conditions in an industrial-scale experiment by sampling metal and silicate phases from a blast furnace at Tatasteel IJmuiden, the Netherlands, with maximum temperatures reaching 1600°C during sampling. Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) performed experiments between 0.5 and 1 GPa pressure, and a temperature range between 1450 and 1750°C.
Here, we review the materials and methods used in these experimental studies, and extend the experimental database by presenting results of metal–silicate Si isotope fractionation experiments done at pressures of 9, 16 and 25 GPa and temperatures between 2150 and 2300°C. We assess to what extent the pressure–temperature effects on Si isotope fractionation can be quantified by combining all available experimental data. Finally, we discuss the implications of our findings for the use of Si isotopic data to constrain core formation in the Earth and other terrestrial planets.
Materials and methods: previously published work
High-pressure experimental methods
High-pressure experiments on Si isotope fractionation have been performed in two different types of apparatus: piston-cylinder presses and multi-anvil presses. A piston-cylinder is a high-pressure apparatus in which several cubic millimetres of sample can be subjected to pressures of up to 4 GPa and temperatures of over 2000°C. The piston-cylinder was developed by Boyd & England (Reference Boyd and England1960), initially to investigate thermodynamic phase-equilibria under HPT conditions. Meanwhile a large variety of piston-cylinders exists, all with very similar operational principles: a sample in a noble metal capsule is inserted into a cylindrical assembly (Fig. 5), which consists mainly of insulating ceramic material, a conducting graphite oven and a thermocouple. The assembly is inserted in the centre of a cylindrically shaped, water-cooled pressure plate. Pressure is applied hydraulically to a piston, which compresses the whole assembly against a top-fixed metal plate (an example is shown in Fig. 6). Temperature is controlled by resistive heating of the graphite furnace. Oxygen fugacity can be controlled by surrounding sample materials with buffer materials. In order to study Si isotope fractionation between metal and silicate, piston-cylinder experiments were run between 0.54 and 1 GPa pressure and in a temperature range between 1450 and 1800°C by Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014). The latter study used a rotating piston-cylinder apparatus (Schmidt et al., Reference Schmidt, Conolly, Günther and Bogaerts2006) that enabled improved density separation of metal and silicate phases.
Pressures above 4 GPa can be reached in a multi-anvil press (e.g. Walker, Reference Walker, Carpenter and Hitch1990), in which smaller samples are subjected to higher loads (Fig. 7A). Again samples can be inserted in a noble-metal capsule, which is commonly cold-welded by the pressure of the multi-anvil press. An example of sample preparation is shown in Fig. 7B. Metal–silicate Si isotope fractionation experiments in multi-anvil presses were previously run at pressures of 7 and 9 GPa and between 2000 and 2200°C by Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a).
Low-pressure experimental methods
Kempl et al. (Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b) used an industrial-scale blast furnace to study Si isotopic behaviour during metal–silicate segregation at low pressure. Industrial-scale hot-metal alloy-producing blast furnaces are used for metal–silicate segregation as a first-step process during steel making. Blast furnaces reach a height of several tens of metres and have a diameter >10 m at their widest point. They are loaded with a burden consisting of natural iron ores (commonly banded iron formations), de-volatised coal, and sinter and pellet materials that are industrially pre-enriched in iron silicates. By controlling oxygen fugacity and temperature in the belly of a blast furnace, hot iron metal is segregated from iron ore, sinter and pellets at high-temperature conditions, and oxygen fugacities close to the iron–wuestite (IW) buffer (Eugster & Wones, Reference Eugster and Wones1962).
Kempl et al. (Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b) obtained coexisting metal and silicate samples produced in a blast furnace at Tatasteel IJmuiden, the Netherlands. After the metal was segregated from the iron ore, both hot metal and silicate slag were tapped and could be sampled for investigation after quenching. The temperatures of these sample sets ranged between 1400 and 1600°C during sampling, whereas oxygen fugacities were close to the IW buffer. In the belly of the blast furnace temperatures were likely higher but can only be estimated to range between 1500 and 2400°C.
Starting materials and compositions
A compilation of starting materials, the nature of the samples and experimental conditions is given in Table 1.
en, enstatite; fo, forsterite; pl, plagioclase; di, diopside.
The Si and Al element concentrations in the metals are given in weight percent. Exact elemental compositions can be found in the respective references.
Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) used experiments containing iron metal with 9 wt% Si and an oxide mixture simulating a BSE composition. The metal phase in their run products typically contained ~8 wt% Si (Shahar et al., Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009). The silicate run product was partially molten, containing both solid olivine grains and quenched melt (Shahar et al., Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011). In both Shahar et al. study an Si isotope spike was added to the silicate starting material (Shahar et al., Reference Shahar, Young and Manning2008) in order to track temporal changes in Si isotope fractionation and assess when isotopic equilibrium was reached. The experimental run duration was up to 60 minutes.
Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010) investigated the Si isotope fractionation between metal and silicate in two aubrite meteorites that contain Si-bearing metal phases. The silicate composition is given by mineral abbreviations in Table 1. In Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010) a detailed explanation of the chemical composition of the metal and silicate phases of the meteorites is given.
In the blast furnace study (Kempl et al., Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b) coexisting hot-metal alloy and silicate glasses of a melilitic composition were sampled. The hot-metal alloy commonly contained 0.3–0.5 wt% Si, while the silicate contained SiO2 concentrations between 33.7 and 35.1 wt%.
Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) made use of different basaltic oxide mixtures combined with either Sn-rich or Sn-free Fe+Si+Mo powder. Sn and Mo were added to lower the melting point of the metal and to enable complete melting at given experimental pressures (Table 1). Each experiment contained about 75 wt% metal powder and 25% silicate. Experimental run times were 30, 90, 240 and 1320 minutes. The run products in Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) were completely molten and consisted of a silicate melt and a metal alloy bearing between 4.7 and 5.8 wt% Si.
Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) performed a time series at 9 GPa and 2100°C in which the silicate consisted of 80 wt% forsterite (fo) and 20 wt% diopside (di) prepared from the major element oxides SiO2, MgO and CaCO3. The metal starting material was a Si-bearing metal alloy with 17 wt% silicon. With increasing experimental runtime this metal Si concentration decreased to 10.0 and 8.8 wt% Si after 13 and 30 minutes, respectively. The SiO2 concentration in the silicate run products varied between 43.1 and 46.2 wt% (Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a). The detailed experimental conditions of all sample sets considered in this work are summarised in Table 2.
*Experiments that authors claim were not of sufficient length to yield full equilibration.
SD, standard deviation, SE, standard error.
Due to the different ways of determining and reporting the analytical uncertainties, the error type is given in brackets.
Si isotope analyses
Silicon has three naturally occurring stable isotopes, 28Si, 29Si and 30Si. Their relative abundances are commonly measured using MC-ICPMS techniques. By using multiple detector systems several isotopes can be measured simultaneously (Fig. 8A). The flat-top intensity peaks enable precise isotope analyses (Fig. 8B). Si isotope variations for Si are, as for other stable isotope systems, reported in the common δ notation, in which the less common isotopes 29Si and 30Si are used to form the isotopic ratios over 28Si. The delta notations for δ30Si (δ30Si = [((30Si/28Sisample)/(30Si/28Sistandard)) – 1] × 1000 [‰]) and δ29Si (δ29Si = [((29Si/28Sisample)/(29Si/28Sistandard)) – 1] × 1000 [‰]) are expressed in per mille deviation of a sample relative to a standard. The common NIST Si isotope standard is the Californian beach sand RM-8546 (formerly known as NBS-28).
The use of different ionisation techniques complicates direct comparisons between results obtained in different laboratories (e.g. see discussion in Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014). Even when comparing results that were obtained by using the same type of sample ionisation, the recent review by Savage et al. (Reference Savage, Armytage, Georg and Halliday2014) shows there are issues with the reported accuracy of some of the literature data on the Si isotope compositions. If not using laser ablation for sample ionisation, MC-ICPMS analyses require dissolving the Si-bearing phases and separating Si quantitatively from the other cations in solution. The different studies listed in Tables 1 and 2 use different sample digestion techniques, which were recently reviewed in Savage et al. (Reference Savage, Armytage, Georg and Halliday2014).
One problem faced by the community studying Si isotope fractionation between metal and silicate is the absence of an international Si-bearing metal standard. This could be a major problem, especially as high Fe/Si ratios in dissolved metal phases can lead to major interferences during analyses due to the formation of iron hydroxides (e.g. Fitoussi et al., Reference Fitoussi, Bourdon, Kleine, Oberli and Reynolds2009). If sample digestion and purification procedures work perfectly there should not be any iron in the sample solutions, but it is unclear if optimal purification is always achieved. An inter-laboratory calibration of an Si-bearing metal standard is even more important when comparing data of samples introduced in an MC-ICPMS by laser ablation.
Materials and methods: this study
In the new experiments performed for this study (Table 1), the silicate starting composition consisted of 80 wt% fo and 20 wt% di, as in Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a). This silicate composition was chosen because it is completely molten at the experimental target pressure and temperature conditions. Instead of starting the experiment with some Si already in the metallic form, as was done in all previous experiments, we added 6 wt% metallic aluminium powder to pure iron metal powder (Table 1). The strategy here was to reduce the sample to such an extent that oxidised silicon from the silicate starting composition would reduce and partition into the metal phase. The silicate and metal starting materials were mixed mechanically in a metal–silicate 50:50 ratio by weight.
The new experiments were run in the 1200 and 5000 t multi-anvil presses at the Bavarian Geo-Institute in Bayreuth, Germany. These presses are capable of running experiments at pressures up to 25 GPa and temperatures up to 3000°C. The pressure in the experiments was 9, 16 or 25 GPa at temperatures of 2150–2300°C. We used capsules of MgO single crystals to avoid melting of a noble metal capsule, iron loss to the capsule material and noble metal contamination of our samples.
The chemical composition of the experimental sample charges was analysed by an electron probe microanalyser. The sample-containing part of the experimental assembly was embedded in epoxy after the experiment and polished down to the point of sample exposure. Fine polishing to a finish of less than 1 μm was done using diamond paste (not silicon carbide) to avoid Si contamination.
Major element analyses of the experiments were performed on carbon-coated samples using a JEOL JXA-8800M electron probe at VU University Amsterdam, the Netherlands. Analyses were carried out by applying an acceleration voltage of 15 nA. A 10 μm beam spot size was applied to metals and silicates. Natural fayalite, diopside, corundum and olivine were used as primary standards to quantify Mg, Ca, Si, Al and Fe. Metal analyses were carried out on a FeSi4 metal alloy. Data were corrected according to the ZAF algorithm (Reed, Reference Reed2005). The typical accuracy of the analysed element concentrations was on the order of 2% relative.
After electron probe analysis, metal and silicate phases from each experiment were separated mechanically, dissolved and purified. The chemical sample digestion procedure was identical to that reported in Kempl et al. (Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b). Atomic masses 28, 29 and 30 were collected simultaneously on the L4, L1 and C Faraday cups of the ThermoFinnigan Neptune MC-ICPMS at VU University Amsterdam, the Netherlands. The sample introduction system consisted of a Cetac Aridus I desolvating system containing an elemental Scientific PFA microcentric Aspire nebuliser system (dry plasma mode). A mass resolution of about RPower = 4300 in high-resolution mode and of RPower = 2500 in medium resolution mode were sufficient (Van den Boorn et al., Reference Van den Boorn, Vroon, van Belle, van der Wagt, Schwieters and van Bergen2006) to resolve all Si isotopes from common polyatomic interferences. Secondary Si isotope standards included the Hawaiian basalt BHVO-2 and an in-house calibrated Si single crystal (Kempl, Reference Kempl2013).
Results
Literature data
The analysed δ30Si and δ29Si isotope signatures of silicates and coexisting metals from both literature studies and the new experiments are listed in Table 3. The δ30Si isotope signatures of silicates range between –0.72‰ (± 0.05‰; 1SD) and 0.21‰ (± 0.16‰; 1SD), while the δ30Si of the metals varies from –2.11‰ (± 0.08‰; 1SD) to –0.85‰ (± 0.06‰; 1SD). In addition, we report the average isotope signature of the samples PL613, PC871 and PR892 gathered by Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) by laser ablation. Because Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010) reports both solution work and laser ablation data, we list the δ30Si and δ29Si signatures of the sample pairs that we chose for this work. The analytical uncertainty in this table is either reported as one standard deviation (1SD) from the number of analyses (Kempl, Reference Kempl2013, this study; Shahar et al., Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) or as one standard error (1SE) from the number of analyses (Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010).
n, total number of analyses per sample material.
For this study and the data of Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) uncertainties are one external standard deviation from the number of analyses. Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010) uses one external standard error of the number of analyses.
The isotope fractionation between metal and silicate, Δ30Sisil-met, is reported and summarised in Table 2. The silicate-metal isotope fractionation of this data collection varies from 0.05‰ (± 0.02‰; 1SE) for a 1-minute piston-cylinder experiment by Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009) at 1800°C and 1 GPa up to 5.69‰ (± 0.10‰; 1SE) and 5.21‰ (± 0.10‰; 1SE) in the natural samples of Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010) equilibrated in solid state over a couple of thousand years between ~850 and ~930°C. The analytical uncertainty in Table 2 is reported in terms of standard deviation or standard error, following the reporting in the individual studies.
This study
Fig. 9 shows a typical back-scattered electron image of the experimental run products. Both the silicate and metal phases melted completely during the experiments, and the metal phases all coalesced to segregate in spherical blebs that were easy to identify and easy to segregate from the silicate in preparation for dissolution.
Electron probe analyses show that after the experiments at 9, 16 and 25 GPa, no measurable Al is left in the metal phase, it has all oxidised. The Si concentration in the metals varies between 3.5 and 4.1 wt%, depending on the experimental run time. The synthesised silicate melts contain SiO2 concentrations between 37.7 and 43.9 wt%.
Standard data, the BHVO-2 basalt standard and the in-house Si single crystal standard were in good agreement with previously analysed data by Abraham et al. (Reference Abraham, Opfergelt, Fripiat, Cavagna, de Jong, Foley, André and Cardinal2008), the compilations by Savage et al. (Reference Savage, Armytage, Georg and Halliday2014) and our own previously published data (Kempl, Reference Kempl2013).
Table 3 shows that the δ30Si of the silicate phases in the new experiments ranges between –0.72 ± 0.05‰ (1SD) and 0.21 ± 0.16‰ (1SD). Metals are depleted in the heavier Si isotopes compared to the silicates in each experiment, with δ30Si ranging between –0.85 ± 0.06‰ (1SD) and –2.11 ± 0.08‰ (1SD). Δ30Sisil-met data for the new experiments (Table 2) vary in a narrow range between 0.71 ± 0.16‰ (1SD) and 1.39 ± 0.13‰ (1SD). This range is within the total range of metal–silicate Si isotope fractionation data reported to date (Table 2) and appears to be consistent with equilibrated high-pressure samples from previous studies (Shahar et al., Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011; Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a; Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014).
Three-isotope space for Si isotopes
Theoretical calculations predicted that Si isotope fractionation is driven by the different chemical bonding environment of silicon. This assumption implies that a stiffer bonded phase, such as given in silicates, would concentrate the heavier Si isotopes, relative to a weaker bonded phase, such as occurs in metals (Georg et al., Reference Georg, Halliday, Schauble and Reynolds2007; Schauble et al., Reference Schauble, Méheut and Hill2007).
Figs 10A–D show the most recent data summary in the three-isotope space of Si from this study (Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010; Shahar et al., Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011; Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a,b; Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014). In all cases, silicates concentrate the heavier isotope fraction, metals the lighter fraction. This is consistent with the predictions of Georg et al. (Reference Georg, Halliday, Schauble and Reynolds2007) and Schauble et al. (Reference Schauble, Méheut and Hill2007). Consistent with mass balance considerations, the silicates provide an infinite Si isotope reservoir and do not show a wide scatter in Si isotopic composition, whereas the metals, which contain a much smaller fraction of the metal–silicate system Si budget, scatter over a wider range in order to equilibrate.
Discussion
Si isotope fractionation between metal and silicate (Δ30Sisil-met)
In this study we present the results of metal–silicate partitioning experiments performed at pressures between 9 and 25 GPa and temperatures between 2150 and 2300°C. These are the highest experimental pressures applied in studies of Si isotope fractionation between metal and silicate. A comparison between these high-pressure data and existing lower-pressure data in terms of Δ30Sisil-met is shown in Fig. 11.
Whether or not chemical and isotopic equilibrium was reached in the experiments is of primary concern. The experimental run time required for Si isotopic equilibration is still a matter of debate. Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) showed that Si isotopic equilibrium is reached between 1.5 and 4 hours depending on the experimental temperature of 1750 or 1450°C, respectively, at pressures between 0.54 and 1 GPa in completely molten experiments. Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) suggest that isotope equilibration between metal and silicate is reached after 30 minutes at 1 GPa and 1800°C in experiments in which the silicate was only partially molten. In Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) Si metal–silicate isotope fractionation is identical within an acceptable error limit for experiments lasting 13 and 30 minutes at 9 GPa and 2100°C, whereas fractionation differs for shorter run durations. In the Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) experiments, both silicate and metal phases were fully molten.
Although our new HPT experiments were run for relatively short times between 2.7 and 5 minutes, they reached Δ30Sisil-met values that are consistent with previous high-pressure data run for significantly longer times (e.g. Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014; Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a). We have two explanations for this observation:
(1) At the very high temperatures of these experiments (>2150°C), at which metal and silicate were both molten, isotopic equilibrium can be reached much faster than at the lower temperatures used in Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014).
(2) Because of the aluminium metal powder added to the iron metal starting material, we induced a speed-up of the chemical reaction for silicon to segregate from silicate and to partition into the metal compared to the 9 GPa experiments of Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a). The direction of this reaction is opposite to the reaction occurring in earlier experimental studies in which the iron metal initially always contained a large amount of Si. Although the final equilibrated Si isotopic distribution should be independent of the reaction direction, the time it takes to reach this equilibrium could well differ.
Temperature dependence of Δ30Sisil-met
As is the case for any isotopic fractionation process, the Si isotopic fractionation between metal and silicate is dependent on temperature, with higher temperatures leading to values for Δ30Sisil-met closer to zero. In Figs 12A–C we compare the temperature-dependent isotope fractionation between metal and silicate derived from Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011), Ziegler et al. (Reference Ziegler, Young, Schauble and Wasson2010), Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) and Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a,b), exclusively using their own data points.
In Fig. 12A the temperature dependences previously obtained from experiments at ~1, 7 and 9 GPa (Shahar et al., Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011; Hin et al., Reference Hin, Fitoussi, Schmidt and Bourdon2014; Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) are compared with each other. The data at 1 and 7 GPa of Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) show the largest isotope fractionation between metal and silicate, with values that are in good agreement with the natural sample data of the Mt Egerton and Norton County meteorites (Ziegler et al., Reference Ziegler, Young, Schauble and Wasson2010).
In contrast, the experimental data of Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) obtained between 0.54 and 1 GPa (Table 2) result in the smallest temperature dependence (Fig. 12A). Our own data previously gathered at 9 GPa and 2100°C (Kempl et al., Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) result in a temperature dependence that lies between the dependencies derived from the Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) experiments (Fig. 12A).
It is still matter of debate what is causing these apparent differences in temperature dependencies. We note that Shahar's silicate sample aliquots were partially molten (as shown in Shahar et al., Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011), consisting of mixtures of olivine grains and a silicate melt. A significant analytical isotope fractionation between silicate crystal and silicate melt was not observed by Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011). However, both analytical work on larger, natural silicate samples and theoretical calculations of major element isotope fractionation have shown that isotope fractionation among silicate minerals does occur, and can reach several per mille variations depending on the crystalline structures and temperature of equilibration (e.g. Meheut et al., Reference Méheut, Lazzeri, Balan and Mauri2007, Reference Méheut, Lazzeri, Balan and Mauri2009; Polyakov, Reference Polyakov2009; Huang et al., Reference Huang, Farkaš and Jacobsen2010, Reference Huang, Chen, Wu and Wang2013). Recently, Meheut & Schauble (Reference Méheut and Schauble2014) and Huang et al. (Reference Huang, Wu, Huang and Wu2014) theoretically calculated the silicon isotope fractionation between different silicate phases focusing on the role of the Si and Si–O bonding environments.
Huang et al. (Reference Huang, Wu, Huang and Wu2014) investigated the expected Si isotope fractionation between mantle minerals at HPT conditions up to 25 GPa and 3000K theoretically. They show that silicate–silicate isotope fractionation decreases with increasing temperature and suggest that at the HPT conditions of the Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) experiments Si isotope fractionation cannot be resolved analytically at present: the external analytical error on the MC-ICPMS is larger than the predicted isotope fractionation between two (or more) different silicates. We note that a small olivine-silicate melt fractionation of Si isotopes in the Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) experiments could provide an explanation for the relatively large external standard deviations in Shahar et al. (Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011)’s silicates calculated in Table 3 from their laser-ablation analyses. Although a distinct difference between olivine and melt cannot be observed, the overall analytical uncertainty in the silicate Si isotope measurements reaches more than 0.2‰.
In contrast, the HPT experiments of Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) and Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) that are equilibrated and considered in Fig. 12A were completely molten, but have significantly different experimental target conditions in terms of pressure and temperature.
Fig. 12B shows the result of the experiments performed in this study, in the pressure range of 9–25 GPa. Overall, the new experimental data are consistent with the range of temperature dependencies previously suggested. Three data points, including the experiments at 16 and 25 GPa, plot on the temperature dependence derived by Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009), whereas the experiment at 9 GPa with an experimental duration of 5 minutes plots on the temperature dependence based on the experiments by Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014). There is no clear trend in Δ30Sisil-met as a function of either temperature or run duration in these new experiments. Fig. 12B supports our hypothesis that despite the short run durations involved, our new experiments are consistent with full isotopic equilibration of Si between metal and silicate. This unexpected result suggests that starting with an Si-free metal in these experiments leads to faster equilibration than starting with an Si-rich metal. Finally, we note that the data in Fig. 12B suggest that the pressure effect on Si isotope fractionation between metal and silicate is minor, at least up to pressures of 25 GPa. If it were large a clear deviation of the 16 and 25 GPa experimental data should have been observed.
Fig. 12C shows data that were obtained from sample sets of the industrial blast furnace (Kempl et al., Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b). The majority of these data plot below the analysed temperature dependence of Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014). Because of the dynamic equilibrium in the SiO2–SiC–SiO–Si cycle within the blast furnace during steel making (Kempl et al., Reference Kempl, Vroon, Zinngrebe and van Westrenen2013b), the isotope fractionation between metal and silicate of these samples should be viewed critically. In addition, the error of the temperature of equilibration of these experiments is relatively large due to the imprecise temperature estimation during steel making.
It is important to note that regardless of which of the temperature dependencies shown in Fig. 12 is most applicable, the differences in Δ30Sisil-met shown in Fig. 11 cannot only be explained by differences in temperature. Correcting all data to a common temperature still leads to major differences in Δ30Sisil-met between, for example, the experiments at 1 GPa performed by Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014). These differences are larger than any reasonable analytical uncertainty and must be related to differences in experimental and/or analytical approach or analytical technique, or differences in silicate and/or metal composition. An extensive discussion of the differences between the Shahar et al. (Reference Shahar, Ziegler, Young, Ricolleau, Schauble and Fei2009, Reference Shahar, Hillgren, Young, Fei, Macris and Deng2011) and Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) data at 1–7 GPa is provided in Hin et al. (Reference Hin, Fitoussi, Schmidt and Bourdon2014) and we will not repeat the pros and cons of those studies here. Suffice to say that the discrepancy between these lower pressure data is not resolved by the addition of the high-pressure data at 9–25 GPa from Kempl et al. (Reference Kempl, Frost, Vroon, Kowalski and van Westrenen2013a) and this study. In this regard, we reiterate that the absence of an international Si-bearing metal standard makes it hard to compare metal Si isotope data obtained in different laboratories using different analytical techniques.
Conclusions and outlook
We have presented the results of new HPT experiments and combined these with a review of literature data to investigate how the Si isotope fractionation behaviour between metal and silicate varies as a function specifically of experimental run time and temperature. We show that although there is no debate about the sign of fractionation (with silicates isotopically heavier than metals), absolute values for Si isotope fractionation between metal and silicate remain difficult to constrain because the experimental database is sometimes contradictory and certainly incomplete. Si isotopic measurements of metals in particular suffer from the absence of a true inter-laboratory comparison.
We conclude that although individual studies have used their measured metal–silicate fractionation of Si isotopes to derive constraints on the amount of Si in the core of the Earth, there is little agreement between different studies and it remains unclear what causes the disagreement. In order to derive accurate quantitative estimates of the Si content of the core of the Earth or other planets, we suggest that a wide range of additional experiments and analyses will be required.
First, not a single experiment exists that has been analysed by different laboratories. To increase the fidelity of the community's results, large-volume experiments should be performed with the resulting sample charges distributed to several laboratories. This would address any differences in analytical approaches and analytical techniques, in particular with respect to the Si isotopic composition determinations of metal phases. In parallel, an inter-laboratory comparison of a metal Si isotopic standard should be set up.
Second, experiments that assess the extent of Si isotopic fractionation between different silicate phases at high pressure and high temperature are required to assess their effect on the existing metal–silicate fractionation database. Third, single laboratories should explore specifically the effects of pressure, temperature and silicate composition on Si isotope fractionation. Studies published to date, including our own, are based on a very small set of experiments that typically do not enable perfect isolation of individual parameters such as temperature or pressure on fractionation.
Acknowledgments
We thank two anonymous reviewers for their extensive comments which significantly improved the manuscript. The MC-ICPMS facility at VU University Amsterdam is funded by the Dutch Organisation for Scientific Research (NWO) by grant no. 175.107.404.01. This study was funded by NWO User Support Programme Planetary Science grant GO-PL/08 to P.Z.V.