Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-25T01:50:16.876Z Has data issue: false hasContentIssue false

Towards the Understanding of Resistive Contrast Imaging in in-situ Dielectric Breakdown Studies Using a Nanoprober Setup

Published online by Cambridge University Press:  01 February 2011

Konstantina Lambrinou
Affiliation:
[email protected], imec, REMO, Leuven, Belgium
Kai Arstila
Affiliation:
[email protected], imec, Leuven, Belgium
Thomas Hantschel
Affiliation:
[email protected], imec, Leuven, Belgium
Andreas Rummel
Affiliation:
[email protected], Kleindiek Nanotechnik GmbH, Reutlingen, Germany
Zsolt Tőkei
Affiliation:
[email protected], imec, PT, Leuven, Belgium
Marianna Pantouvaki
Affiliation:
[email protected], imec, Leuven, Belgium
Kristof Croes
Affiliation:
[email protected], imec, Leuven, Belgium
Piotr Czarnecki
Affiliation:
[email protected], imec, Leuven, Belgium
Laure Carbonell
Affiliation:
[email protected], imec, Leuven, Belgium
Olivier Richard
Affiliation:
[email protected], imec, Leuven, Belgium
Stephan Kleindiek
Affiliation:
[email protected], Kleindiek Nanotechnik GmbH, Reutlingen, Germany
Ingrid De Wolf
Affiliation:
[email protected], imec, REMO, Leuven, Belgium
Wilfried Vandervorst
Affiliation:
[email protected], imec, Leuven, Belgium
Get access

Abstract

This work aims at attaining a more complete understanding of the principles governing resistive contrast imaging (RCI) of copper/low-k interconnects used for dielectric breakdown studies in a nanoprober scanning electron microscope (SEM) system. RCI is employed in such in situ dielectric breakdown studies to facilitate the localization of interconnect defect sites related to various stages in the degradation process of the low-k dielectric material. This work shows that RCI is suitable for detecting high-resistance sites, like opens, in copper/low-k interconnects. Moreover, RCI demonstrates potential in locating defects that lie deep in the test structure and are, thus, not detectable by SEM. A model is also proposed to explain the formation of RCI images of specific interconnect test structures with complex layout.

Type
Research Article
Copyright
Copyright © Materials Research Society 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Nokuo, T. and Furya, H., “Fault site localization technique by imaging with nanoprobes”, Electronic Device Failure Analysis 2, 1622 (2009).Google Scholar
2 Cole, E. I. Jr., “Resistive contrast imaging applied to multilevel interconnection failure analysis”, Proc. 1989 VMIC Conference, pp. 176182 (1989).Google Scholar
3 Tökei, Zs., Croes, K. and Beyer, G. P., “Reliability of low-k interconnects”, Microelectronics Reliability 87(3), 348354 (2010).Google Scholar