Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-24T19:44:01.435Z Has data issue: false hasContentIssue false

A Robotic Method for Creating Radiation Maps Using Mercuric Iodide Sensor

Published online by Cambridge University Press:  21 February 2011

Masao Kume
Affiliation:
The Robotics Institute, Carnegie Mellon University, Pittsburgh PA 15213
Pradeep K. Khosla
Affiliation:
The Robotics Institute, Carnegie Mellon University, Pittsburgh PA 15213
Get access

Abstract

In this paper we describe the development of a robotic system that uses Mercuric Iodide (HgI2) sensors to create a map of radiation intensity in the environment. The sensors are mounted at the end-effector of a PUMA 560 manipulator. Data from these sensors is used to compute the radiation intensity. A control system is developed that moves the end-effector along constant intensity contours. The experiments use light sources (instead of radiation sources) and demonstrate the efficacy of such a system to create radiation maps.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Feddema, J.T. and Lee, C.S.G., “Adaptive image feature prediction and control for visual tracking with a hand- eye coordinated camera”, IEEE trans. on Systems, Man, and Cybernetics, Vol.20,No.5,1990, pp. 11721183 Google Scholar
[2] Weiss, L.E., Sanderson, A.C., and Neuman, C.P., “Dynamic sensor-based control of robots with visual feedback”, IEEE Journal of Robotics and Automation, Vol. RA–3,No.5,1987, pp.404417 Google Scholar
[3] Papanikolopoulos, N.P., Nelson, B., and Khosla, P.K., “Full 3-D tracking; the controlled active vision paradigm”, Proc. of IEEE Int. Symposium on Intelligent Control, August, 1992.Google Scholar
[4] Schlesinger, T.E., Bao, X.J., James, R.B., and Frank, L., “Energy Dispensive X-ray and Gamma-ray Spectra measured at room temperature using compact Mercuric Iodide Detectors”, Fifth Topical Meeting on Robotics and Remote Handling, Knoxville, TN, April, 1993 Google Scholar
[5] Kume, M. and Khosla, P.K., “A manipulator control system for creating radiation maps using Mercuric Iodide (HgI2) Detectors”, Fifth Topical Meeting on Robotics and Remote Handling, Knoxville, TN, April, 1993 Google Scholar
[6] Papanikolopoulos, N.P., “Controlled Active Vision”, PhD thesis, Carnegie Mellon University, 1992 Google Scholar