Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-30T23:58:40.072Z Has data issue: false hasContentIssue false

Practical electrical contact resistance measurement method for bulk thermoelectric devices

Published online by Cambridge University Press:  25 January 2013

Rahul P. Gupta
Affiliation:
Marlow Industries Inc., a subsidiary of II-VI Inc., Dallas TX 75238
Robin McCarty
Affiliation:
Marlow Industries Inc., a subsidiary of II-VI Inc., Dallas TX 75238
Jim Bierschenk
Affiliation:
Marlow Industries Inc., a subsidiary of II-VI Inc., Dallas TX 75238
Jeff Sharp
Affiliation:
Marlow Industries Inc., a subsidiary of II-VI Inc., Dallas TX 75238
Get access

Abstract

As thermoelectric (TE) element length decreases, the impact of contact resistance on TE device performance grows more significant. In fact, for a TE device containing 100-μm tall Bi2Te3TE elements, the figure of merit ratio (ZTDevice/ZTMaterial) drops from 0.9 to 0.5 as the contact resistivity increases from 5 x 10-07 to 5 x 10-06 Ω-cm2. To understand the effects of contact resistance on bulk TE device performance, a reliable experimental measurement method is needed. There are many popular methods to extract contact resistance such as Transmission Line Measurements (TLM) and Kelvin Cross Bridge Resistor method (KCBR), but they are only well-suited for measuring metal contacts on thin films and do not necessarily translate to measuring contact resistance on bulk thermoelectric materials. The authors present a new measurement technique that precisely measures contact resistance (on the order of 5 x 10-07 Ω-cm2) on bulk thermoelectric materials by processing stacks of bulk, metal-coated TE wafers using TE industry standard processes. One advantage of this technique is that it exploits realistic TE device manufacturing techniques and results in an almost device-like structure, therefore representing a realistic value for electrical contact resistance in a bulk TE device. Contact resistance measurements for metal contacts to n- and p-type Bi2Te3 alloys are presented and an estimate of the accuracy of the measurements is discussed.

Type
Articles
Copyright
Copyright © Materials Research Society 2013 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Goldsmid, H.J., Electronic Refrigeration, pp. 9, Pion Limited, London (1986).Google Scholar
Arnold, A.S., Wilson, J.S., and Boshier, M.G., Review of Scientific Instruments, 69, 1236 (1998).CrossRefGoogle Scholar
Zhang, S.L., Microelectronic Engineering, 70, 174 (2003).CrossRefGoogle Scholar
Narayanan, V., Liu, Z., Shen, Y.M.N., Kim, M., and Kan, E.C., IEDM Tech. Digest, 87 (2000).Google Scholar
Zimin, S.P., Kuznetsov, V.S., and Prokaznikov, A.V., Applied Surface Science, 91, 355 (1995).CrossRefGoogle Scholar
Yamada, K., Tomita, K., and Ohmi, T., Applied Physics Letters, 64, 3449 (1994).CrossRefGoogle Scholar
Chen, Z. Z., Qin, Z.X., Tong, Y.Z., Hu, X.D., Yu, T.J., Yang, Z.J., Ding, X.M., Li, Z.H., and Zhang, G.Y., Material Science and Engineering B, 100, 199 (2003).CrossRefGoogle Scholar
Katz, A., Nakahara, S., Savin, W., and Weir, B. E., Journal of Applied Physics, 68, 4133 (1990).CrossRefGoogle Scholar
Aboelfotoh, M. O., Lin, C. L., and Woodall, J. M., Applied Physics Letters, 65, 3245 (1994).CrossRefGoogle Scholar
Gupta, R.P., Xiong, K., White, J.B., Cho, Kyeongjae, Alshareef, H.N., and Gnade, B.E., Journal of The Electrochemical Society, 157(6), H666 (2010).CrossRefGoogle Scholar