Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-28T08:52:32.600Z Has data issue: false hasContentIssue false

Impedancemetric Technique for NOx Sensing Using a YSZ-Based Electrochemical Cell

Published online by Cambridge University Press:  26 February 2011

L. Peter Martin
Affiliation:
[email protected], Lawrence Livermore National Lab., Engineering Technologies Division, P.O. Box 808, L - 353, Livermore, CA, 94551, United States, 925-423-9831
Leta Y. Woo
Affiliation:
[email protected], Lawrence Livermore National Laboratory, Livermore, CA, 94551, United States
Robert S. Glass
Affiliation:
[email protected], Lawrence Livermore National Laboratory, Livermore, CA, 94551, United States
Get access

Abstract

An impedancemetric technique for NOx sensing using a yttria-stabilized zirconia (YSZ) electrochemical cell is reported. The cell consists of a dense YSZ substrate disk with two YSZ/metal-oxide electrodes deposited on the same side. The cell is completely exposed to the test gas (no air reference). The NOx and O2 response of the cell were evaluated during constant-frequency operation at frequencies in the range from 1 to 1000 Hz. At 10 Hz, the NOx response (as measured by phase angle shift) is shown to be linear with concentration over the range from 8-50 ppm, with comparable response to both NO and NO2. A method of operation is described which enables compensation for the O2 response at oxygen concentrations greater than approximately 4%. This mode of operation allows the sensor to provide sub-10 ppm detection of NOx irrespective of the O2 concentration. The sensor exhibits good stability during continuous operation for more than 150 hr. It was observed that the O2 response of the cell may be too slow to be of practical use, taking several minutes to equilibrate after changing the concentration by a few percent. However, data will be presented which demonstrate that this response is related to the metal oxide used for the electrode, and that more rapid response times can be achieved by modification of the electrode material.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Menil, F., Coillard, V., and Lucat, C., Sensors Actuators B, 67, 1 (2000).Google Scholar
2. West, D. L., Montgomery, F. C. and Armstrong, T. R., J. Electrochem. Soc., 153, H23 (2006).Google Scholar
3. Dutta, A. and Ishihara, T., Sensors and Actuators B, 108, 309 (2005).Google Scholar
4. Martin, L. P., Pham, Q. and Glass, R., Sensors and Actuators B, 96, 53 (2003).Google Scholar
5. Brosha, E. L., Mukundan, R., Brown, D. R., Garzon, F. H., Visser, J. H., Zanini, J. H., Zhou, Z. and Logethetis, E. M., Sensors and Actuators B, 69, 171 (2000).Google Scholar
6. Lu, G., Miura, N., and Yamazoe, N., Sensors and Actuators B, 35, 130 (1996).Google Scholar
7. Di Bartolomeo, E., Kaabbuathong, N., D'Epifanio, A., Grilli, M. L., Traversa, E., Aono, H., Sadaoka, Y., J. of the European Ceram. Soc., 24, 1187 (2004).Google Scholar
8. Nakatou, M. and Miura, N., J. Ceram. Soc. Japan, 112, S532 (2004).Google Scholar
9. Nakatou, M. and Miura, N., Solid State Ionics, 176, 2511 (2005).Google Scholar
10. Wu, N., Chen, Z., Xu, J., Chyu, M. and Mao, S. X., Sensors and Actuators B, 110, 49 (2005).Google Scholar
11. Woo, L. Y., Martin, L. P. and Glass, R. S., submitted to J. Electrochem. Soc. (August, 2006).Google Scholar
12. Martin, L. P., Woo, L. Y. and Glass, R. S., submitted to J. Electrochem. Soc. (July, 2006).Google Scholar