Get access

Abstract

Vertically-aligned multiwalled carbon nanotubes (VA-MWCNTs) were grown using plasma enhanced chemical vapor deposition (PECVD) technique. These VA-MWCNTs were then dip coated by Poly methyl methacrylate (PMMA) followed by annealing. Samples were then polished to expose the tips of CNTs. Biological molecules Glucose Oxidase (GOx) were then immobilized on the exposed tips of these nanoelectrode ensembles. Here we present further characterization of these devices, with results on the detection limits and measurement stability. We found that these sensors can be reused for longer than eight months when kept in proper storage conditions.

Type
Research Article
Copyright
Copyright © Materials Research Society 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Lin, Y., Lu, F., Tu, Y. and Ren, Z., Nanoletters 4, 191 (2004).10.1021/nl0347233Google Scholar
2. Wild, S., Roglic, G., Green, A., Sicree, R., and Kind, H., Diabetes care 27, 1047 (2004).Google Scholar
3. Baxendale, M. J., Mater. Sci.: Mater. Electron 14, 657 (2003).Google Scholar
4. Lin, Y.H. and Wang, W.J., Front. Biosci. 10, 492 (2005).Google Scholar
5. Wang, J., Electroanalysis 17, 7 (2005).10.1002/elan.200403113Google Scholar
6. Pang, P. X., He, D., Luo, S. and Cai, Q., Sensors and Actuators B 137, 134 (2009).Google Scholar
7. Perez, B., Pumera, M., Valle, M.D., Merkoci, A. and Alegret, S., Journal of Nanoscience and Nanotenhnology 5, 1694 (2005).Google Scholar
8. Hao, T. et. al., Analytical Biochemistry 331, 98 (2004).Google Scholar
9. Jia, J., Guan, W., Sim, M., Li, Y. and Li, H., Sensors 8, 1712 (2008).Google Scholar
10. Müller, D., Biochem. Z. 199, 136 (1928).Google Scholar
11. Keilin, D., Hartree, E.F., Biochem. J. 50 (3), 331 (1952).10.1042/bj0500331Google Scholar
12. Raba, J. and Mottola, H. A., Critical Reviews in Analytical Chemistry 25(1), 1 (1995).Google Scholar
13. Balasubramanian, K. and Burghard, M., Anal. Bioanal. Chem. 385, 452 (2006).Google Scholar
14. Wang, J. and Musameh, M., Analyst 128, 1382 (2003).Google Scholar
15. Burmeister, J.J., Gerhandt, G.A., Anal. Chem. 73, 1037 (2001).Google Scholar
16. Battaglini, F., Bartlett, P.N. and Wang, J.H., Anal. Chem. 72, 502 (2000).Google Scholar
17. Menda, J. et al., Appl. Phys. Lett. 87, 173106 (2005).Google Scholar
18. Chiu, W.M. and Chang, Y.A., J. of Applied Polymer Science 107, 1655 (2008).Google Scholar
19. Wang, Z., Liu, S., Wu, P. and Cai, C., Anal. Chem 81, 1638 (2009).Google Scholar
20. Kumar, S. A., and Jain, V.K., Sensors and Transducers Journal 98, 16 (2008).Google Scholar