Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-28T15:49:03.168Z Has data issue: false hasContentIssue false

Floating-Gate Ion Sensitive Field-Effect Transistor for Chemical and Biological Sensing

Published online by Cambridge University Press:  01 February 2011

Ben Zhao
Affiliation:
Department of Electrical and Computer Engineering, Polytechnic University, Brooklyn, NY
Tsunehiro Sai
Affiliation:
Othmer Department of Chemical and Biological Science and Engineering, Polytechnic University, Brooklyn, NY
Arifur Rahman
Affiliation:
Xilinx Research Labs, Xilinx, Inc, San Jose, CA
Kalle Levon
Affiliation:
Othmer Department of Chemical and Biological Science and Engineering, Polytechnic University, Brooklyn, NY
Get access

Abstract

This paper presents the use of Floating-Gate Ion Sensitive Field-Effect Transistor (FGISFET) as a real-time chemical and biological sensor. The structure of FGISFET is similar to that of an electrically erasable programmable read-only memory (EEPROM). The floating-gate of a FGISFET is connected to an exposed metallic structure, which serves as a probe for detecting ionic activities. By applying ion-sensitive chemical and biological materials to the floating gate, its threshold voltage can be modulated in the presence of selective chemical or biological targets. As a demonstration, FGISFETs have been fabricated in 1.2 μm process technology available through MOSIS [1]. Our preliminary measurements confirmed the basic design and operation of FGISFET, and using doped aniline trimer (TANI) as a sensing material, we were able to sense 70ppm of ammonium gas.

Type
Research Article
Copyright
Copyright © Materials Research Society 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] MOSIS (Metal Oxide Semiconductor Implementation Service). A multiproject fabrication service run by ARPA (The Advanced Research Projects Agency).Google Scholar
[2] Zhou, Y., Yu, B., Shiu, E., Levon, K., Analytical Chemistry 76, 26892693(2004)Google Scholar
[3] Zhou, Y., Yu, B., Levon, K., Biosensors and Bioelectronics, In Press(2004)Google Scholar
[4] Bergveld, P., Sensors and Actuators B: Chem. 88, 1 (2003)Google Scholar
[5] Jakobson, C.G., Dinnar, U., Feinsod, M., and Nemirovsky, Y., IEEE Sensors Journal, vol. 2, no. 4, August 2002.Google Scholar
[6] Janata, J., Proc. IEEE, vol. 91(6), pages 864869, 2003.Google Scholar
[7] Janata, J., Chem. Rev., vol. 90, no. 5, pp. 691703, 1990 Google Scholar
[8] Janata, J., New York: Plenum, 1989 Google Scholar
[9] Pavan, P., Bez, R., Olivo, P., and Zanoni, E., Proc. IEEE, vol. 85, no. 8, august 1997 Google Scholar
[10] Kang, S.M., and Leblebici, Y., CMOS digital integrated circuits: analysis and design, 3rd Ed., McGraw-Hill, Boston (2003), p. 94, 464Google Scholar
[11] Terada, K., Nishiyama, K., Hatanaka, K.I., Solid State Electronics, vol. 45, pages 3540, 2001 Google Scholar
[12] Lokshin, N.A., Pyshkina, O.A., Golubev, V.V., Sergeyev, V.G., Zezin, A.B., and Kabanov, V.A., Macromolecules 2001, 34, 54805486 Google Scholar
[13] Ghita, M., Gheorghe, M., Visinoiu, A., MIEL 2000, vol. 2, May 14–17, 2000 Google Scholar
[14] MacDiarmid, A.G. and Epstein, A. J., Synthetic Metals 69 (1995) 8592 Google Scholar
[15] Kuo, C., Chen, S., Hwang, G., and Kuo, H., Synthetic Metals 93(1998) 155160 Google Scholar
[16] Dominis, A.J., Spinks, G.M., Kane-Maguire, L.A.P., Wallace, G.G., Synthetic Metals 129(2002) 165172 Google Scholar