Fixed Contamination on Steel Surfaces: First Use of Quartz Crystal Microgravimetry to Measure Oxide Growth on Process Steels Under Conditions Typical of Nuclear Reprocessing.

Published online by Cambridge University Press:  08 February 2012

Rebecca C. Woodhouse
Affiliation:
Engineering Department, Lancaster University, Lancaster LA1 4YW
Richard J. Wilbraham
Affiliation:
Engineering Department, Lancaster University, Lancaster LA1 4YW
Colin Boxall*
Affiliation:
Engineering Department, Lancaster University, Lancaster LA1 4YW
Get access

Abstract

During the lifetime of a nuclear facility, radioactive material may become deposited onto process and structural material surfaces. Due to their high corrosion resistance, steels comprise the largest class of metal-based materials encountered on nuclear sites. A greater understanding of the mechanisms of how contaminant radionuclides interact with and attach to process steels in nuclear plant environments is required in order to enable informed decisions to be made about the design and effective application of decontamination techniques, reducing secondary wastes.

There is limited literature relating to radionuclide sorption mechanisms on steels. Key studies have found that sorbed contamination is almost entirely located in the outermost oxide layers formed at steel surfaces. Thus, a molecular level investigation of contaminant uptake during induced oxide formation would be beneficial in developing steel decontamination strategies.

Stainless steel 316L is commonly employed in the nuclear industry in process streams and pipework. Thus, we describe work carried out on electrochemically accelerated oxide growth on 316L and SS2343 (a 316L analog) in nitric acid media and its characterisation using combined voltammetric and microgravimetric measurements. These allow identification of active, passive, high voltage passive, transpassive and secondary passivation regimes in the associated current voltage curves. EQCM on SS2343 coated quartz crystal piezoelectrodes, combined with potentiodynamic polarisation data have allowed us to determine that fastest net growth of surface oxide occurs in the low voltage passive regime. Further, we have directly measured the growth of that layer by using in situ microgravimetry for the first time. We will be shortly using the methods described above and radionuclide surrogates for the study of contaminant uptake during oxide formation and uptake onto preformed oxide layers. XPS will be used to determine layer composition and mode of contaminant uptake.

Type
Research Article
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Rouppert, F., Ivoallan, A. and Argeron, C., presented at the WM’02 Conference, Tuscon, AZ, 2002.Google Scholar
2. Shimizu, R., Sawada, K., Enokida, Y. and Yamamato, I., J. Nucl. Sci. Technol. 43(6), 694698 (2006).Google Scholar
3. Francis, A. J., Dodge, C. J., Gillow, J. B., Halada, G. P. and Clayton, C. R., Report No.64946, 2001.Google Scholar
4. Bojinov, M., Betova, I., and Raicheff, R., J. Electroanal. Chem. 430 (1–2), 169-178 (1997).Google Scholar
5. Wijesinghe, T. L. S. L. and Blackwood, D. J., App. Sci. 253(2), 10061009 (2006).Google Scholar
6. Olsson, C. –O. A. and Landolt, D., Electrochim. Acta. 48 (9), 1093-1104 (2003).Google Scholar
7. Padhy, N., Raul, R., Kamachi Mudali, U. and Raj, B., App. Surf. Sci. 257 (11), 5088-5097 (2011).Google Scholar
8. Betova, I., Bojinov, M., Laitinen, T., Makela, K., Pohjanne, P. and Saari, T., Corr. Sci. 44 (12), 2675-2697 (2002).Google Scholar
9. Bojinov, M., Betova, I., Fabricius, G., Laitinen, T., Raicheff, R., and Saario, T., Corr. Sci. 41 (8), 1557-1584 (1999).Google Scholar
10. Padhy, N., Ningshen, S., Kamachi Mudali, U., and Raj, B., Scripta Materialia. 62(1), 4548 (2010).Google Scholar
11. Fauvet, P., Balbaud, F., Robin, R., Tran, Q. T., Mugnier, A., and Espinoux, D., J. Nucl. Mat 375, 5264 (2008).Google Scholar
12. Inc, Maxtek, RQCM: Research Quartz Crystal Microbalance; operation and service manual, (2002).Google Scholar