Surface Treated PDMS by UV-Vis Light for Microfluidic Device

Published online by Cambridge University Press:  01 February 2011

Seisuke Kano
Affiliation:
[email protected], National Institute of Advanced Industrial Science and Techinology, Advanced Manufacturing Research Institute, Tsukuba, Japan
Sohei Matsumoto
Affiliation:
[email protected], National Institute of Advanced Industrial Science and Techinology, Advanced Manufacturing Research Institute, Tsukuba, Ibaraki, Japan
Naoki Ichikawa
Affiliation:
[email protected], National Institute of Advanced Industrial Science and Techinology, Advanced Manufacturing Research Institute, Tsukuba, Japan
Get access

Abstract

Hydrophobic property of PDMS surface was improved by the 400 W UV-Vis lamp light irradiation in the atmospheric condition for several ten minutes. As a result of this surface treatment, the surface became to hydrophilic character for one month long. This surface treatment technique applied to PDMS micro-fluidic device and verified valve-less switching. The UV-Vis light irradiated to PDMS micro fluidic pattern with partly covered by aluminum foil. Finally inlet and outlets were connected 0.5 mm diameter tubes. The syringe pumps injected the distilled water into the inlet of the PDMS micro channel at the flow rates of 0.5, 5.0, and 50 μl/min for the both width channel. As results of water injection water flowed only the UV-Vis treated channel at the flow rates of 0.5 and 5.0 μl/min. On the other hand, the water flowed for all channels at the flow rate of 50 μl/min. This result was observed from 5.0 μl/min flow again for both width devices which dried by air. These results were occurred by the difference of the flow conductance and wettability. The mechanism of this hyrophilicity of PDMS was reported to form Si-O in the surface by means of glassy surface. From the IR spectra, the Si-O-Si peak shifted to higher wave number for UV-Vis irradiated PDMS than the untreated PDMS comparing with the other IR peaks. This result showed that the Si-O-Si network bonding of PDMS changed to the O-Si-O bonding around the surface.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Makamba, H., Kim, J. H., Lim, K., Park, N. and Hahn, J. H., Electrophoresis, 24, 3607 (2003).Google Scholar
2. Bhattacharya, S., Datta, A., Berg, J. M., et al., J Microelectromechanical Systems, 14 (3), 590 (2005).Google Scholar
3. Manca, M., Cortese, B., Viola, I., Arico, A. S., Cingolani, R. and Gigli, G., Langmuir, 24 (5), 1833 (2008)Google Scholar
4. Vladkova, T. G., Keranov, I. L., Dineff, P. D., Youroukov, S. Y., Avramova, I. A., Krasteva, N. and Altankov, G. P., Nucl. Inst. Meth, B 236, 552 (2005).Google Scholar
5. “UV/ozone modification of poly (dimethyl siloxane) microfluidic channels,” Y. Berdichevsky, J. Khandurina, A. Guttman, Y.-H. Lo, Sensors and Actuators B, 97, 102 (2004).Google Scholar
6. Yamamoto, T. and Fujii, T, Proceedings of uTAS 2004, 2, 133 (2004).Google Scholar
7. Kano, S., Matsumoto, S., Ichikawa, T.N., Proceedings of uTAS 2007, 2, 1037 (2007).Google Scholar