State of the art in development of millimeter wave radiometric imaging systems is analyzed and discussed. One-dimension array of 16 radiometers with mechanical scanning of the offset parabolic antenna is experimentally demonstrated that offers rms 0.03 K at time constant 1 s and instant field of view of 4×60 mrad.