Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-28T08:23:34.560Z Has data issue: false hasContentIssue false

Mechanosensitive Channels Activity in a Droplet Interface Bilayer System

Published online by Cambridge University Press:  30 January 2014

Joseph Najem
Affiliation:
Biomolecular Materials and Systems Laboratory, Virginia Tech, Blacksburg, VA 24061, U.S.A.
Myles Dunlap
Affiliation:
Biomolecular Materials and Systems Laboratory, Virginia Tech, Blacksburg, VA 24061, U.S.A.
Sergei Sukharev
Affiliation:
Department of Biology, University of Maryland, College Park, MD 20742, U.S.A.
Donald J. Leo
Affiliation:
College of Engineering, University of Georgia, Athens, GA 30609, U.S.A.
Get access

Abstract

This paper presents the first attempts to study the large conductance mechano-sensitive channel (MscL) activity in an artificial droplet interface bilayer (DIB) system. A novel and simple technique is developed to characterize the behavior of an artificial lipid bilayer interface containing mechano-sensitive (MS) channels. The experimental setup is assembled on an inverted microscope and consists of two micropipettes filled with PEG-DMA hydrogel and containing Ag/AgCl wires, a cylindrical oil reservoir glued on top of a thin acrylic sheet, and a piezoelectric oscillator actuator. By using this technique, dynamic tension can be applied by oscillating axial motion of one droplet, producing deformation of both droplets and area changes of the DIB interface. The tension in the artificial membrane will cause the MS channels to gate, resulting in an increase in the conductance levels of the membrane. The results show that the MS channels are able to gate under an applied dynamic tension. Moreover, it can be concluded that the response of channel activity to mechanical stimuli is voltage-dependent and highly related to the frequency and amplitude of oscillations.

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Sarles, S. A., Stiltner, L. J., Williams, C. B. and Leo, D. J., ACS applied materials & interfaces 2(12), 36543663 (2010).CrossRefGoogle Scholar
Sarles, S. A. and Leo, D. J., Analytical chemistry 82(3), 959966 (2010).CrossRefGoogle Scholar
Sarles, S. A., Virginia Polytechnic Institute and State University, 2010.Google Scholar
Sarles, S. A. and Leo, D. J., Journal of intelligent material systems and structures 20(10), 12331247 (2009).CrossRefGoogle Scholar
Hwang, W. L., Chen, M., Cronin, B., Holden, M. A. and Bayley, H., Journal of the American Chemical Society 130(18), 58785879 (2008).CrossRefGoogle Scholar
Sukharev, S. I., Martinac, B., Arshavsky, V. Y. and Kung, C., Biophysical Journal 65(1), 177183 (1993).CrossRefGoogle Scholar
Blount, P., Sukharev, S. I., Moe, P. C., Martinac, B. and Kung, C., in Methods in Enzymology, edited by Conn, P. M. (Academic Press, 1999), Vol. Volume 294, pp. 458482.Google Scholar
Sukharev, S. I., Martinac, B., Blount, P. and Kung, C., Methods 6(1), 5159 (1994).CrossRefGoogle Scholar
Petrov, A. G., Analytica Chimica Acta 568 (1–2), 7083 (2006).CrossRefGoogle Scholar
Sarles, S. A., Madden, J. D. and Leo, D. J., Soft Matter 7(10), 46444653 (2011).CrossRefGoogle Scholar
Sukharev, S. I., Sigurdson, W. J., Kung, C. and Sachs, F., The Journal of General Physiology 113(4), 525540 (1999).CrossRefGoogle Scholar
Akitake, B., Anishkin, A. and Sukharev, S., The Journal of General Physiology 125(2), 143154 (2005).CrossRefGoogle Scholar
Szabo, G., Gray, M. C. and Hewlett, E. L., Journal of Biological Chemistry 269(36), 2249622499 (1994).Google Scholar
Saint, N., Lacapère, J.-J., Gu, L.-Q., Ghazi, A., Martinac, B. and Rigaud, J.-L., Journal of Biological Chemistry 273(24), 1466714670 (1998).CrossRefGoogle Scholar