Hostname: page-component-586b7cd67f-t7fkt Total loading time: 0 Render date: 2024-11-24T18:43:19.939Z Has data issue: false hasContentIssue false

Development of High Resolution X-Ray CT Technique for Highly-Radioactive Material

Published online by Cambridge University Press:  30 March 2012

Kozo Katsuyama
Affiliation:
Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashiibaraki, Ibaraki, Japan, 311-1393
Akihiro Ishimi
Affiliation:
Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashiibaraki, Ibaraki, Japan, 311-1393
Koji Maeda
Affiliation:
Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashiibaraki, Ibaraki, Japan, 311-1393
Tsuyoshi Nagamine
Affiliation:
Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashiibaraki, Ibaraki, Japan, 311-1393
Takeo Asaga
Affiliation:
Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashiibaraki, Ibaraki, Japan, 311-1393
Get access

Abstract

In order to observe the structural change in the interior of irradiated fuel assembly, the non-destructive post irradiation examination technique using X-ray computer tomography (X-ray CT) was developed.

In this X-ray CT system, the 12 MeV X-ray pulses were used in synchronization with the switch-in of the detector in order to minimize the effects of the gamma ray emissions from the irradiated fuel assembly then clear cross section CT image of irradiated fuel assembly could be successfully obtained. Also, this non-destructive technique can be applied to observe the inner condition of the high radioactive materials such as a radioactive waste.

Type
Articles
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Hounsfield, G.N., Computerized transverse axial scanning (tomography), Part 1, Br. J. Radiol. 46 (1973) 1016.10.1259/0007-1285-46-552-1016Google Scholar
[2] Satoh, K. et al. . “High Energy X-Ray Computed Tomography for Non-Destructive Inspections of Complicated Products”, International Conference on NDE in the Nuclear Vessel Industries (13th), Kyoto, pp.5357 (1995)Google Scholar
[3] Katsuyama, K., et al. . “Development of Non-destructive Post-irradiation Examination Technique Using High-energy X-ray Computer TomographyTransactions American Nuclear Society, Vol. 91 481482 (2004).Google Scholar
[4] Katsuyama, K., et al. . “High energy X-ray CT study on the central void formations and the fuel pin deformations of FBR fuel assemblies”, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 255, No. 2, 365372 (2007).10.1016/j.nimb.2006.12.087Google Scholar