Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-28T16:05:51.498Z Has data issue: false hasContentIssue false

Corrosion of Copper in 1 M NaCl under Strictly Anoxic Conditions

Published online by Cambridge University Press:  01 February 2011

Martin Bojinov
Affiliation:
VTT Technical Research Centre of Finland, VTT Industrial Systems, Espoo, FIN-02044, Finland
Timo Laitinen
Affiliation:
VTT Technical Research Centre of Finland, VTT Industrial Systems, Espoo, FIN-02044, Finland
Kari Mäkelä
Affiliation:
VTT Technical Research Centre of Finland, VTT Industrial Systems, Espoo, FIN-02044, Finland
Margit Snellman
Affiliation:
Saanio & Riekkola, Finland
Lars Werme
Affiliation:
SKB, Sweden
Get access

Abstract

The corrosion of copper in 1 M NaCl has been investigated at room temperature and at 80°C by an on-line resistance probe, solution analysis of dissolved copper and weight loss measurements. At room temperature, corrosion of the copper as indicated by an increase of the probe resistance has been detected during the first 60–80 h of exposure. After the corrosion potential has reached the immunity region of Cu, a decrease in the resistance of the sensor is observed, probably due to redeposition of Cu from the solution. It can be concluded that the corrosion of copper at room temperature virtually stops after 60–80 h due to the anoxic conditions established in the experiments. The similarity in the trends of the corrosion and redox potential during exposure seems to indicate that Cu(II) contained in the native oxide on Cu and/or formed by homogeneous oxidation of Cu(I) during the initial oxic period of exposure acts as a redox-agent determining the chemical conditions in the closed system.

Type
Research Article
Copyright
Copyright © Materials Research Society 2004

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Beverskog, B. and Puigdomenech, I., SKI Report 98:19, Swedish Nuclear Power Inspectorate, Stockholm, 1998.Google Scholar
2. Vuorinen, U. and Snellman, M., Posiva Working Report 98–61, Posiva Oy, Helsinki, Finland, 1998.Google Scholar
3. Laitinen, T., Mäkelä, K., Saario, T., and Bojinov, M., SKI Report 01:2, Swedish Nuclear Power Inspectorate, Stockholm, 2001.Google Scholar
4. Betova, I., Beverskog, B., Bojinov, M., Kinnunen, P., Mäkelä, K., Petersson, S.-O., and Saario, T., Electrochem. Solid State Lett. 6, B19 (2003).Google Scholar
5. Rosborg, B., Karnland, O., Quirk, G., and Werme, L., in Prediction of Long Term Corrosion Behaviour in Nuclear Waste Systems, EFC event N° 256, 26–29 November, 2001, Cadarache, France (CD-ROM publication).Google Scholar
6. Ueno, T., Azumi, K., and Seo, M., J. Electroanal. Chem. 540, 97 (2003).Google Scholar
7. King, F., Ahonen, L., Taxen, C., Vuorinen, U., and Werme, L., SKB Report TR-01–23, Swedish Nuclear Fuel and Waste Management Co., Stockholm, 2001.Google Scholar
8. Sharma, V.K. and Millero, F.J., J. Solution Chem. 17, 581 (1988).Google Scholar
9. King, F., Quinn, M.J., and Litke, C.D., J. Electroanal. Chem. 385, 45 (1995)Google Scholar