Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-28T10:10:58.830Z Has data issue: false hasContentIssue false

Characterization of Mortar with Mineral Additives

Published online by Cambridge University Press:  11 November 2013

M. R. Mejía Durán
Affiliation:
Universidad Autónoma de Querétaro, Querétaro, México.
A. A. Torres Acosta
Affiliation:
Instituto Mexicano del Transporte, Sanfandila, Querétaro, México. Universidad Marista de Querétaro, Querétaro, México.
M.G. Arroyo Contreras
Affiliation:
Universidad Autónoma de Querétaro, Querétaro, México.
M. Rendón Belmonte
Affiliation:
Instituto Mexicano del Transporte, Sanfandila, Querétaro, México.
Get access

Abstract

It has been an increase on the number of concrete structures with corrosion induced damage in Mexico in recent years. It is also well known that cathodic protection (CP) is the only method that stops corrosion in an efficient way. Since the 1990’s Florida and other USA states have been installing in concrete pile substructures, in bridges and piers, a three part hybrid galvanic CP system. This hybrid galvanic CP system includes a thermal sprayed part (located at the aerial zone of the pile), a zinc mesh encapsulated in mortar and inside a glass fiber jacket (located at the change in ties zone), and a submerged zinc bulk anode (in the submerged zone). From a previous investigation performed by the present authors, it has been found that the mortar inside the fiberglass form may decrease the mesh anode activation and thus decrease the CP system efficiency. Therefore, this investigation includes an evaluation of different additions placed in mortar to increase its electrical and ionic conductivity to increase the efficiency of the entire hybrid system. Additions include carbon, zinc and alumina powders, and this investigation presents preliminary experimental results obtained from the tested mortars (i.e. mortar physical characterization: electrical resistivity, ultrasonic pulse velocity, and total void content).

Type
Articles
Copyright
Copyright © Materials Research Society 2013 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Andrade, C., Alonso, M.C., and Molina, F.J. (1993) “Cover cracking as a function of rebar corrosion: Part I- Experimental test,” Mater. Struct., 26: p. 453464.CrossRefGoogle Scholar
Del Valle-Moreno, A., Peréz López, T., and Martínez-Madrid, M. (2001) “Corrosion Phenomena in Reinforced Concrete Structures,” Technical Publication No. 182, Mexican Institute of Transportation (Sanfandila, Queretaro, Mexico: IMT) (in Spanish).Google Scholar
DURAR (2000) “Manual for inspecting, evaluating and diagnosing corrosion in reinforced concrete structures,” CYTED Ibero-American Program, XV Subprogram: Corrosion/Environmental Impact on Materials, (Maracaibo, Venezuela: La Universidad del Zulia).Google Scholar
Genescá, J. and Ávila, M.J. (1986) “Beyond Rust: The Fight against Corrosion,” (Mexico City, Mexico: Fondo de Cultura Económica) (in Spanish).Google Scholar
Rendón Belmonte, M., Torres Acosta, A.A., Martínez Madrid, M. (2012). “Electrochemical evaluation of a zinc galvanic PC system used in concrete bridge substructures,” Final Project Report No. EI 09/11, Instituto Mexicano del Transporte, Sanfandila, Querétaro, México, septiembre (in Spanish).Google Scholar
Torres-Acosta, A.A. and Martínez-Madrid, M. (2003) “Residual Life of Corroding Reinforced Concrete Structures in Marine Environment,” Journal of Materials in Civil Engineering, 15, 4: p. 344353.CrossRefGoogle Scholar