Hostname: page-component-78c5997874-g7gxr Total loading time: 0 Render date: 2024-11-02T23:33:43.572Z Has data issue: false hasContentIssue false

An efficient uric acid biosensor based on tin oxide thin film matrix

Published online by Cambridge University Press:  02 April 2013

Kashima Arora
Affiliation:
Department of Physics and Astrophysics, University of Delhi, Delhi 110007, India
Monika Tomar
Affiliation:
Physics Department, Miranda House, University of Delhi, Delhi 110007, India
Vinay Gupta
Affiliation:
Department of Physics and Astrophysics, University of Delhi, Delhi 110007, India
Get access

Abstract

Uric acid biosensor has been developed using tin oxide (SnO2) thin film. The electrochemistry of the developed thin film based electrode is investigated by using cyclic voltammetry. The obtained results demonstrate that the semiconducting SnO2 matrix offers a striking electrocatalytic activity to the immobilized uricase towards the oxidation of uric acid and promotes the transfer of electrons from the active sites of enzyme onto the electrode. SnO2 thin film matrix gives a high sensitivity of 0.2 mA/mM and a shelf life of 20 weeks. Moreover, SnO2 electrode exhibits excellent selectivity and outstanding analytical stability and reproducibility, which enables a reliable and selective determination of uric acid. The SnO2 based uric acid biosensor shows a linear variation in a wide range from 0 to 1.0 mM of uric acid concentration and the Michaelis Menten Constant (Km) is estimated to be 0.28 mM which indicated the high affinity of uricase towards its analyte (uric acid). The results indicate that the SnO2 thin film matrix offers a new and promising platform for the development of novel biosensors.

Type
Articles
Copyright
Copyright © Materials Research Society 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Li, C., Liu, Y., Li, L., Du, Z., Xu, S., Zhang, M., Yin, X. and Wang, T., Talanta 77, 455 (2008).CrossRefGoogle Scholar
Salimi, A., Sharifi, E., Noorbakhsh, A., Soltanian, S., Biophysical Chemistry 125, 540 (2007).CrossRefGoogle Scholar
Zhang, F., Wang, X., Ai, S., Sun, Z. and Wan, Q., Analytica Chimica Acta 519, 155 (2004).CrossRefGoogle Scholar
Safavi, A., Maleki, N. and Farjami, E., Biosensors and Bioelectronics 24, 1655 (2009).CrossRefGoogle Scholar
Sattarahmady, N., Heli, H. and Faramarzi, F., Talanta 82, 1126 (2010).CrossRefGoogle Scholar
Sharma, A., Tomar, M. and Gupta, V., Sensors and Actuators B 156, (2011) 743752.CrossRefGoogle Scholar
Van Tran, T., Turrell, S., Eddafi, M. and Capoen, B., J. Mol. Struc. 976, 314 (2010).CrossRefGoogle Scholar
Arora, K., Tomar, M. and Gupta, V., Biosensors and Bioelectronics 30, 333 (2011).Google Scholar